Specification: Part Number 1035039 Supply voltage: 4.5 V ... 5.5 V Working temperature range: -10 °C ... +60 °C Resolution: 10 mm Enclosure rating: IP 65 Output current: 30 Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, 1.5 m Protection class standard: IEC 60529 Initialization time: 40 s Connection type: Cable, 1.5 m Mechanical interface: Measuring drum, knurled surface Smallest measurin
Specification: Part Number 1035045 Working temperature range: -10 °C ... +60 °C Maximum operating speed: 1,500 U/min Connection type: Cable, 1.5 m MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, 1.5 m EMC: EN 61000-6-2, EN 61000-6-3 Pulses per revolution: 1,000 Error limits 'O' ring surface: ± 4 mm Reference signal, number: 1
Specification: Part Number 1035047 Error limits knurled surface: ± 0.5 mm MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Initialization time: 40 s Maximum operating speed: 1,500 U/min Electrical interface: 10 V ... 30 V, HTL/Push pull, Cable, 1.5 m Connection type: Cable, 1.5 m Mass: 0.42 kg Bearing lifetime: 2 x 10^9 revolutions Supply voltage: 10 V ... 30 V Resistance to vibration:
Specification: Part Number 1035048 Enclosure rating: IP 65 Working temperature range: -10 °C ... +60 °C Mass: 0.42 kg Air humidity: 90 % Supply voltage: 10 V ... 30 V MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Maximum operating speed: 1,500 U/min Storage temperature range: -40 °C ... +70 °C, without package Output current: 30 Electrical interface: 10 V ... 30 V, HTL/Push pull,
Specification: Part Number 1035049 Initialization time: 40 s Storage temperature range: -40 °C ... +70 °C, without package Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Reference signal, number: 1 Resolution: 0.2 mm Mass: 0.42 kg Connection type: Cable, 1.5 m Working temperature range: -10 °C ... +60 °C Output current: 30 Enclosure rating: IP 65 MTTFd: mean time to dangerous failure: 600 a (
Specification: Part Number 1035050 Reference signal, number: 1 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Reference signal, position: 90 °, electronically, gated with A and B Mechanical interface: Measuring drum, knurled surface Working temperature range: -10 °C ... +60 °C Smallest measuring step: 0.025 mm Bearing lifetime: 2 x 10^9 revolutions Supply voltage: 10 V ... 30 V Resista
Specification: Part Number 1036071 Resolution: 1 mm Electrical interface: 10 V ... 30 V, HTL/Push pull, Cable, M12, 8-pin, 1.5 m Maximum operating speed: 1,500 U/min Enclosure rating: IP 65 Protection class standard: IEC 60529 Supply voltage: 10 V ... 30 V Pulses per revolution: 200 Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) EMC: EN 61000-6-2, EN 61000-6-3 Air humidity: 90 % Reference signal
Specification: Part Number 1035051 Storage temperature range: -40 °C ... +70 °C, without package Enclosure rating: IP 65 Air humidity: 90 % Error limits 'O' ring surface: ± 4 mm Connection type: Cable, 1.5 m Protection class standard: IEC 60529 Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Smallest measuring step: 2.5 mm Mechanical interface: Measuring drum, O ring surface Initialization time:
Specification: Part Number 1035052 Enclosure rating: IP 65 Initialization time: 40 s Storage temperature range: -40 °C ... +70 °C, without package Reference signal, position: 90 °, electronically, gated with A and B Maximum operating speed: 1,500 U/min EMC: EN 61000-6-2, EN 61000-6-3 Mechanical interface: Measuring drum, O ring surface Air humidity: 90 % Error limits 'O' ring surface: ± 4 mm Supp
Specification: Part Number 1035053 Bearing lifetime: 2 x 10^9 revolutions Storage temperature range: -40 °C ... +70 °C, without package Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Smallest measuring step: 0.05 mm Output current: 30 Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Connection type: Cable, 1.5 m Electrical interface: 10 V ... 30 V, HTL/Push pull, Cable, 1.5 m Mechanical
Specification: Part Number 1035054 Reference signal, position: 90 °, electronically, gated with A and B EMC: EN 61000-6-2, EN 61000-6-3 Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Mechanical interface: Measuring drum, O ring surface Output current: 30 Connection type: Cable, 1.5 m Enclosure rating: IP 65 Protection class standard: IEC 60529 Reference signal, number: 1 Working temperature range: -
Specification: Part Number 1037803 Mass: 0.42 kg Output current: 30 Smallest measuring step: 0.25 mm Bearing lifetime: 2 x 10^9 revolutions Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Supply voltage: 10 V ... 30 V Working temperature range: -10 °C ... +60 °C Initialization time: 40 s Storage temperature range: -40 °C ... +70 °C, without package Electrical interface: 10 V ... 30 V, HTL/Push pu
Specification: Part Number 1035040 Mechanical interface: Measuring drum, knurled surface Storage temperature range: -40 °C ... +70 °C, without package Enclosure rating: IP 65 Connection type: Cable, 1.5 m EMC: EN 61000-6-2, EN 61000-6-3 MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Smallest measuring step: 0.25 mm Reference signal, number: 1 Maximum operating speed: 1,500 U/min Output
Specification: Part Number 1035041 Air humidity: 90 % Supply voltage: 4.5 V ... 5.5 V Connection type: Cable, 1.5 m Smallest measuring step: 0.05 mm Mass: 0.42 kg Working temperature range: -10 °C ... +60 °C Output current: 30 Storage temperature range: -40 °C ... +70 °C, without package Resolution: 0.2 mm Bearing lifetime: 2 x 10^9 revolutions Reference signal, position: 90 °, electronicall
Specification: Part Number 1035042 Pulses per revolution: 2,000 Air humidity: 90 % Initialization time: 40 s Smallest measuring step: 0.025 mm Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, 1.5 m Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Enclosure rating: IP 65 Resolution: 0.1 mm MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Reference signal, position:
Specification: Part Number 1035745 Reference signal, position: 90 °, electronically, gated with A and B MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Connection type: Cable, M12, 8-pin, 1.5 m Initialization time: 40 s Enclosure rating: IP 65 Error limits knurled surface: ± 0.5 mm Resolution: 1 mm Working temperature range: -10 °C ... +60 °C Maximum operating speed: 1,500 U/min Air h
Specification: Part Number 1037527 Error limits knurled surface: ± 0.5 mm Mass: 0.42 kg Air humidity: 90 % Reference signal, position: 90 °, electronically, gated with A and B Pulses per revolution: 2,000 Connection type: Cable, M12, 8-pin, 1.5 m Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, M12, 8-pin, 1.5 m Smallest measuring step: 0.025 mm EMC: EN 61000-6-2, EN 61000-6-3 Reference sign
Specification: Part Number 1035043 Protection class standard: IEC 60529 MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Reference signal, position: 90 °, electronically, gated with A and B Resolution: 10 mm Smallest measuring step: 2.5 mm Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) EMC: EN 61000-6-2, EN 61000-6-3 Enclosure rating: IP 65 Pulses per revolution: 20 Res
Specification: Part Number 1036267 EMC: EN 61000-6-2, EN 61000-6-3 Supply voltage: 4.5 V ... 5.5 V Bearing lifetime: 2 x 10^9 revolutions Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, 1.5 m Protection class standard: IEC 60529 Connection type: Cable, 1.5 m Error limits 'O' ring surface: ± 4 mm Storage temperature range: -40 °C ... +70 °C, without package Mass: 0.42 kg Smallest measuring
Specification: Part Number 1035044 Maximum operating speed: 1,500 U/min Resolution: 1 mm Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) EMC: EN 61000-6-2, EN 61000-6-3 Reference signal, position: 90 °, electronically, gated with A and B Error limits 'O' ring surface: ± 4 mm Mass: 0.42 kg Pulses per revolution: 200 Initialization time: 40 s Smallest measuring step: 0.25 mm Storage temperature
Specification: Part Number 1036587 Mass: 0.42 kg Supply voltage: 4.5 V ... 5.5 V Initialization time: 40 s Reference signal, number: 1 Smallest measuring step: 0.025 mm Electrical interface: 4.5 V ... 5.5 V, TTL/RS422, Cable, M12, 8-pin, 1.5 m Connection type: Cable, M12, 8-pin, 1.5 m Maximum operating speed: 1,500 U/min Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Storage temperature range: -40 °
Specification: Part Number 1035767 Mechanical interface: Measuring drum, knurled surface Air humidity: 90 % Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) Electrical interface: 10 V ... 30 V, HTL/Push pull, Cable, 1.5 m Supply voltage: 10 V ... 30 V Mass: 0.42 kg Pulses per revolution: 3 Reference signal, position: 90 °, electronically, gated with A and B Working temperature range: -10
Specification: Part Number 1036157 Protection class standard: IEC 60529 Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Error limits knurled surface: ± 0.5 mm Smallest measuring step: 12.5 mm Electrical interface: 10 V ... 30 V, HTL/Push pull, Cable, 1.5 m Pulses per revolution: 4 Resolution: 50 mm MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Storage temperature range: -40 °C ... +70
Specification: Part Number 1036156 Bearing lifetime: 2 x 10^9 revolutions Supply voltage: 10 V ... 30 V Protection class standard: IEC 60529 Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Resolution: 13.34 mm Reference signal, position: 90 °, electronically, gated with A and B Reference signal, number: 1 Pulses per revolution: 15 Enclosure rating: IP 65 Maximum operating speed: 1,500 U/min Init
Specification: Part Number 1035571 Reference signal, position: 90 °, electronically, gated with A and B Resolution: 5 mm Working temperature range: -10 °C ... +60 °C Bearing lifetime: 2 x 10^9 revolutions Storage temperature range: -40 °C ... +70 °C, without package Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) EMC: EN 61000-6-2, EN 61000-
Specification: Part Number 1035572 Working temperature range: -10 °C ... +60 °C Mechanical interface: Measuring drum, O ring surface Supply voltage: 10 V ... 30 V Output current: 30 Connection type: Cable, 1.5 m Reference signal, number: 1 Initialization time: 40 s Enclosure rating: IP 65 Mass: 0.42 kg Bearing lifetime: 2 x 10^9 revolutions Maximum operating speed: 1,500 U/min Storage tempera
Specification: Part Number 1035055 Mass: 0.42 kg Working temperature range: -10 °C ... +60 °C Reference signal, number: 1 Output current: 30 Maximum operating speed: 1,500 U/min Initialization time: 40 s Electrical interface: 10 V ... 30 V, HTL/Push pull, Cable, 1.5 m Reference signal, position: 90 °, electronically, gated with A and B Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Error limits 'O