Specification: Part Number 1035047 Error limits knurled surface: ± 0.5 mm MTTFd: mean time to dangerous failure: 600 a (EN ISO 13849-1) Initialization time: 40 s Maximum operating speed: 1,500 U/min Electrical interface: 10 V ... 30 V, HTL/Push pull, Cable, 1.5 m Connection type: Cable, 1.5 m Mass: 0.42 kg Bearing lifetime: 2 x 10^9 revolutions Supply voltage: 10 V ... 30 V Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (EN 60068-2-6) EMC: EN 61000-6-2, EN 61000-6-3 Resolution: 10 mm Smallest measuring step: 2.5 mm Pulses per revolution: 20 Air humidity: 90 % Protection class standard: IEC 60529 Enclosure rating: IP 65 Storage temperature range: -40 °C ... +70 °C, without package Reference signal, number: 1 Mechanical interface: Measuring drum, knurled surface Reference signal, position: 90 °, electronically, gated with A and B Output current: 30 Resistance to shocks: 50 g, 7 ms (EN 60068-2-27) Working temperature range: -10 °C ... +60 °C