General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.19 Reduction factor r 304 0.66 Reduction factor r Brass 0.33 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 800 Hz Hysteresis 1 ... 15 typ. 5 %
Cylindrical inductive sensor with 30mm housing diameter, type of material - PBT. This series have cable PVC connection type and 10mm operating distance. Voltage type - DC, flush installation, 2 wire. General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.22 Reduction factor r Cu
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 300 Hz Current consumption Measuring plate not detecte
General specifications Switching element function AC NO Rated operating distance 10 mm Installation flush Output polarity AC Assured operating distance 0 ... 7.2 mm Nominal ratings Operating voltage 220 V AC ± 20 % Switching frequency 45 ... 65 Hz Hysteresis 2 ... 10 typ. 5 % Operating current 5 ... 200 mA Off-state current 0.7 ... 1.5 mA typ. No-load supply current 6 mA Ambient conditions A
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Operating voltage 5 ... 25 V Switching frequency 0 ... 300 Hz Hysteresis 3 % Cu
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 300 Hz Current consumption Measuring plate not detected min. 3 mA Measu
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 300 Hz Current consumption Measuring plate not detected min. 3 mA Measu
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 300 Hz Hysteresis 1 ... 10 typ. 5 % Current consumption
General specifications Switching element function PNP NO/NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.15 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarit
General specifications Switching element function PNP NO/NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.15 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarit
General specifications Switching element function NPN NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.32 Reduction factor r Cu 0.32 Reduction factor r 304 0.72 Reduction factor r Brass 0.43 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 650 Hz Hysteresis 1 ... 15 typ. 5 %
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.32 Reduction factor r Cu 0.32 Reduction factor r 304 0.72 Reduction factor r Brass 0.43 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 650 Hz Hysteresis 1 ... 15 typ. 5 %
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.32 Reduction factor r Cu 0.32 Reduction factor r 304 0.72 Reduction factor r Brass 0.43 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 650 Hz Hysteresis 1 ... 15 typ. 5 %
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.32 Reduction factor r Cu 0.32 Reduction factor r 304 0.72 Reduction factor r Brass 0.43 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 650 Hz Hysteresis 1 ... 15 typ. 5 %
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.32 Reduction factor r Cu 0.32 Reduction factor r 304 0.72 Reduction factor r Brass 0.43 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 650 Hz Hysteresis 1 ... 15 typ. 5 % Reve
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.32 Reduction factor r Cu 0.32 Reduction factor r 304 0.72 Reduction factor r Brass 0.43 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 650 Hz Hysteresis 1 ... 15 typ. 5 %
General specifications Switching element function PNP NO/NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polarity protection rev
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 250 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polarity protection
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 3000 Hz Hysteresis 0 ... 0.3 typ. 0.1 % Reverse polari
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation non-flush Output polarity Selective Assured operating distance 0 ... 12.15 mm Reduction factor r Al 1/0 Reduction factor r Cu 1/0 Reduction factor r St37 0/1 Reduction factor r Brass 1/0 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 100 Hz Reverse polarity protec
General specifications Switching element function PNP NO contact Frequency range 0.1 ... 1 Hz , adjustable Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 15 ... 60 V DC Reverse polarity protection reverse polarity prote
General specifications Switching element function PNP NO contact Frequency range 1 ... 10 Hz , adjustable Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 15 ... 60 V DC Reverse polarity protection reverse polarity protec
General specifications Switching element function PNP NO contact Frequency range 10 ... 100 Hz , adjustable Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 15 ... 60 V DC Reverse polarity protection reverse polarity prot
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 150 Hz Current consumption Measuring plate not detected min. 3 mA Mea
General specifications Switching element function AC NO/NC Rated operating distance 15 mm Installation flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop less than or e
General specifications Switching element function AC NO/NC Rated operating distance 15 mm Installation flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 25 Hz Hysteresis typ. 3 % Voltage drop less than or equal to 7
General specifications Switching element function AC NO/NC Rated operating distance 15 mm Installation flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop less than or equal
General specifications Switching element function AC NO/NC Rated operating distance 15 mm Installation flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Nominal ratings Operating voltage AC 20 ... 253 V 1) Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop less than o
General specifications Switching element function AC NO Rated operating distance 15 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop less than or
General specifications Switching element function AC NO/NC Rated operating distance 15 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 25 Hz Hysteresis typ. 3 % Voltage drop less than or equal t