General specifications Switching element function NAMUR, NC Rated operating distance 1.5 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.19 Reduction factor r 304 0.65 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 5000 Hz Hysteresis 1 ... 10 typ. 5 % Suitable for 2:
General specifications Switching element function NAMUR, NC Rated operating distance 1.5 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.19 Reduction factor r 304 0.65 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 5000 Hz Hysteresis typ. % Suitable for 2:1 technology yes , Reverse polari
General specifications Switching element function NAMUR, NC Rated operating distance 1.5 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 5000 Hz Hysteresis 1 ... 10 typ. 5 % Suitable for 2:1
General specifications Switching element function NAMUR, NC Rated operating distance 1.5 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 5000 Hz Hysteresis typ. % Suitable for 2:1 technology yes , Reverse polarity
General specifications Switching element function NAMUR, NC Rated operating distance 1.5 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 5000 Hz Hysteresis typ. % Suitable for 2:1 technology yes , Reverse polarity
General specifications Switching element function NAMUR, NC Rated operating distance 1.5 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 5000 Hz Hysteresis 1 ... 10 typ. 5 % Suitable for 2:1
General specifications Switching element function NPN NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2500 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reve
General specifications Switching element function NPN NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2500 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reve
General specifications Switching element function NPN NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2500 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reve
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 500 Hz Reverse polarity protection reverse polarity protected Short-cir
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity
General specifications Switching element function PNP NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 500 Hz Reverse polarity protection reverse polarity protected Short-cir
General specifications Switching element function PNP NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 500 Hz Reverse polarity protection reverse polarity protected Short-cir
General specifications Switching element function NAMUR, NC Rated operating distance 1.5 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 1.22 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 5000 Hz Hysteresis typ. % Current consumption
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1000 Hz Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop less than or equal to 3 V Operating current 0 ..
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1000 Hz Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop less than or equal to 3 V Operating current 0 ..
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 9 typ. 5 % Current consumpti
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 2000 Hz Hysteresis typ. 3 % Current consumption
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 2000 Hz Hysteresis typ. 3 % Current consumption Measuring plate not d
General specifications Switching element function NPN NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis 0 ... 10 typ. % Reverse polarity protection reverse pol
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis 0 ... 10 typ. % Reverse polarity protection reverse pol
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis 0 ... 10 typ. % Reverse polarity protection reverse pol
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 300 Hz Hysteresis 1 ... 10 typ. 5 % Current consumption
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 300 Hz Current consumption Measuring plate not detected min. 3 mA Measu
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation flush Output polarity Safety Function Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Safety Integrity Level (SIL) up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fa
General specifications Switching element function NAMUR, NC Rated operating distance 10 mm Installation flush Output polarity Safety Function Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Safety Integrity Level (SIL) up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fa
General specifications Switching element function PNP NO/NC Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.38 Reduction factor r 304 0.71 Reduction factor r Brass 0.45 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.19 Reduction factor r 304 0.66 Reduction factor r Brass 0.33 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 800 Hz Hysteresis 1 ... 15 typ. 5 %