PEPPERL+FUCHS

Image
Part Number
Description
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.41 Reduction factor r Cu 0.39 Reduction factor r 304 0.78 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 1500 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse pola
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.41 Reduction factor r Cu 0.39 Reduction factor r 304 0.78 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 1500 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse pola
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.41 Reduction factor r Cu 0.39 Reduction factor r 304 0.78 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 1500 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity p
General specifications Switching element function DC NO Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.49 Reduction factor r Cu 0.47 Reduction factor r 304 0.76 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5 % Reverse polarity protection conducting S
General specifications Switching element function DC NC Rated operating distance 4 mm Installation flush Assured operating distance 0 ... 3.06 mm Reduction factor r Al 0.49 Reduction factor r Cu 0.47 Reduction factor r 304 0.76 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 0 ... 1000 Hz Reverse polarity protection conducting Short-circuit protection pulsing Voltage dro
General specifications Switching element function DC NC Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.49 Reduction factor r Cu 0.47 Reduction factor r 304 0.76 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5 % Reverse polarity protection conducting S
General specifications Switching element function PNP NO contact Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polarity protection reverse pola
General specifications Switching element function NO/NC programmable Rated operating distance 4 mm Installation flush Output polarity AS-Interface Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.23 Reduction factor r Cu 0.21 Reduction factor r 304 0.7 Slave type Standard slave AS-Interface specification V2.1 Required master specification greater or equal V2.1 Nominal ratings
General specifications Switching element function NO/NC programmable Rated operating distance 4 mm Installation flush Output polarity AS-Interface Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.23 Reduction factor r Cu 0.21 Reduction factor r 304 0.7 Slave type A/B slave AS-Interface specification V3.0 Required master specification greater or equal V2.1 Nominal ratings Ope
General specifications Switching element function NPN NO Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function NPN NC Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function PNP NC Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse polar
General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 32 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Installation conditions F 100 mm Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 80 Hz Hysteresis
General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 32 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Installation conditions F 100 mm Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 80 Hz Hysteresis
General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 32 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Installation conditions F 100 mm Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 80 Hz Hysteresis
General specifications Switching element function AC NO/NC Rated operating distance 40 mm Installation flush Output polarity AC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 3 % Short-circuit protection no Voltage dr
General specifications Switching element function DC NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 50 Hz Hysteresis 0 ... 20 typ. 5 % Reverse polarity protection revers
General specifications Switching element function NAMUR, NC Rated operating distance 5 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 400 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity prote
General specifications Switching element function NAMUR, NC Rated operating distance 5 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 400 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity pro
General specifications Switching element function NAMUR, NC Rated operating distance 5 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 400 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse polari
General specifications Switching element function NAMUR, NC Rated operating distance 5 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 400 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse polari
General specifications Switching element function NAMUR, NC Rated operating distance 5 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 400 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity pro
General specifications Switching element function DC NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.33 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 350 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse po