General specifications Switching element function AC/DC NO/NC Rated operating distance 15 mm Installation flush Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Nominal ratings Operating voltage DC 20 ... 300 V Operating voltage AC 20 ... 253 V Switching frequency 0 ... 25 Hz Hysteresis typ. 3 % Short-circuit protec
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation quasi flush Output polarity NAMUR Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 450 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection rever
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation quasi flush Output polarity NAMUR Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 450 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection rever
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation quasi flush Output polarity NAMUR Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 450 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection rever
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation quasi flush Output polarity NAMUR Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.29 Reduction factor r 304 0.76 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 450 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection rever
General specifications Switching element function DC NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Reduction factor r Brass 0.5 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 500 Hz Hysteresis typ. 5% Reverse polarity prot
General specifications Switching element function DC NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Reduction factor r Brass 0.5 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 500 Hz Hysteresis typ. 5% Reverse polarity prot
General specifications Switching element function DC NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Reduction factor r Brass 0.5 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 500 Hz Reverse polarity protection reverse polarit
General specifications Switching element function DC NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Reduction factor r Brass 0.5 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 500 Hz Reverse polarity protection reverse polarit
General specifications Switching element function DC NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Reduction factor r Brass 0.5 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 500 Hz Reverse polarity protection reverse polarit
General specifications Switching element function NAMUR, NC Rated operating distance 2 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.1 Reduction factor r 304 0.5 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 1000 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity prot
General specifications Switching element function NAMUR, NC Rated operating distance 2 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.23 Reduction factor r Cu 0.21 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 1000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity pr
General specifications Switching element function NAMUR, NC Rated operating distance 2 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.23 Reduction factor r Cu 0.21 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 1000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity protection reverse polar
General specifications Switching element function NAMUR, NC Rated operating distance 2 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.23 Reduction factor r Cu 0.21 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 1000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity protection reverse polar
General specifications Switching element function NAMUR, NC Rated operating distance 2 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.23 Reduction factor r Cu 0.21 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Operating voltage 5 ... 25 V Switching frequency 0 ... 1000 Hz Hysteresis 1 ... 1
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.23 Reduction factor r Cu 0.21 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity protection reve
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.23 Reduction factor r Cu 0.21 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity protection reverse
General specifications Switching element function DC NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.23 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 800 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse po
General specifications Switching element function DC NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.23 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 800 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse po
General specifications Switching element function DC NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.23 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V DC Switching frequency 0 ... 800 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse
General specifications Switching element function DC NC Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.23 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 800 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse po
General specifications Switching element function DC NC Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.23 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 800 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse po
General specifications Switching element function NO/NC programmable Rated operating distance 2 mm Installation flush Output polarity AS-Interface Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.23 Reduction factor r Cu 0.21 Reduction factor r 304 0.7 Slave type Standard slave AS-Interface specification V2.1 Required master specification greater or equal V2.1 Nominal ratings
General specifications Switching element function NAMUR, NC Rated operating distance 2 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 2000 Hz Hysteresis typ. 5 % Current consumption Mea
General specifications Switching element function NAMUR, NC Rated operating distance 2 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 2000 Hz Hysteresis typ. 5 % Current consumption Mea
General specifications Switching element function AC/DC NO/NC Rated operating distance 20 mm Installation flush Output polarity AC/DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage DC 20 ... 300 V Operating voltage AC 20 ... 250 V Switching frequency 200 Hz VDC / 30 Hz VAC Hysteresis 3 ... 10 % Reverse polarity
General specifications Switching element function NAMUR, NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection r
General specifications Switching element function DC NO Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.49 Reduction factor r Cu 0.47 Reduction factor r 304 0.76 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5 % Reverse polarity protection conducting S
General specifications Switching element function DC NC Rated operating distance 4 mm Installation flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.49 Reduction factor r Cu 0.47 Reduction factor r 304 0.76 Nominal ratings Operating voltage 3.5 ... 30 V Switching frequency 0 ... 1000 Hz Reverse polarity protection conducting Short-circuit protection
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.41 Reduction factor r Cu 0.39 Reduction factor r 304 0.78 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 1500 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity p