General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 32 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Installation conditions F 100 mm Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 80 Hz Hysteresis
General specifications Switching element function AC NO/NC Rated operating distance 40 mm Installation flush Output polarity AC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 3 % Short-circuit protection no Voltage dr
General specifications Switching element function DC NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 50 Hz Hysteresis 0 ... 20 typ. 5 % Reverse polarity protection revers
General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.35 Reduction factor r 304 0.83 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 1 Hz Hysteresis typ. 3 % Reverse polarity protection reverse pol
General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.35 Reduction factor r 304 0.83 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.35 Reduction factor r 304 0.83 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.35 Reduction factor r 304 0.83 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.35 Reduction factor r 304 0.83 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO contact Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.35 Reduction factor r 304 0.83 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 1 Hz Hysteresis typ. 3 % Reverse polarity protection reverse
General specifications Switching element function PNP NO contact Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.35 Reduction factor r 304 0.83 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1 Hz Hysteresis typ. 3 % Reverse polarity protection reverse
General specifications Switching element function PNP NO contact Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.35 Reduction factor r 304 0.83 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse
General specifications Switching element function PNP NO contact Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.35 Reduction factor r 304 0.83 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse
General specifications Switching element function PNP NO contact Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.35 Reduction factor r 304 0.83 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse
General specifications Switching element function PNP NO contact Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.35 Reduction factor r 304 0.83 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse
General specifications Switching element function PNP NO contact Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.35 Reduction factor r 304 0.83 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse
General specifications Switching element function PNP NC Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.35 Reduction factor r 304 0.83 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 1 Hz Hysteresis typ. 3 % Reverse polarity protection reverse polari
General specifications Switching element function DC NO/NC Rated operating distance 50 mm Installation flush Output polarity DC Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis 0 ... 20 typ. 5 % Reverse polarity protection reve
General specifications Switching element function NO contact Rated operating distance 50 mm Installation flush Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis 0 ... 20 typ. 5 % Reverse polarity protection reverse polarity protected
General specifications Switching element function NC contact Rated operating distance 50 mm Installation flush Assured operating distance 0 ... 40.5 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis 0 ... 20 typ. 5 % Reverse polarity protection reverse polarity protected
General specifications Switching element function PNP NO Rated operating distance 100 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 81 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.35 Reduction factor r 304 1 Reduction factor r Brass 0.47 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 10 Hz Hysteresis typ. 8 % Revers
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation non-flush Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.36 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 500 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse pol
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation non-flush Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.36 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 500 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse polarity protected Shor
General specifications Switching element function NAMUR, NC Rated operating distance 20 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.35 Reduction factor r 304 0.79 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 250 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse
General specifications Switching element function AC/DC NO/NC Rated operating distance 20 mm Installation non-flush Output polarity AC/DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.35 Reduction factor r 304 0.79 Nominal ratings Operating voltage 20 ... 253 V Operating voltage DC 20 ... 300 V Switching frequency 0 ... 25 Hz Hysteresis typ. 3
General specifications Switching element function NAMUR, NC Rated operating distance 20 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.35 Reduction factor r 304 0.79 Nominal ratings Installation conditions A 5 mm B C Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 .
General specifications Switching element function AC/DC NO/NC Rated operating distance 20 mm Installation non-flush Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.35 Reduction factor r 304 0.79 Nominal ratings Operating voltage DC 20 ... 300 V Operating voltage AC 20 ... 253 V Switching frequency 0 ... 25 Hz Hysteresis typ. 3 % Short-circuit pro
General specifications Switching element function AC/DC NO Rated operating distance 20 mm Installation non-flush Output polarity AC/DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.35 Reduction factor r 304 0.79 Nominal ratings Operating voltage 20 ... 253 V Operating voltage DC 20 ... 300 V Switching frequency 0 ... 25 Hz Hysteresis typ. 3 %
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.5 Reduction factor r 304 0.6 ... 1 Mounting angle Al Amplifier housing Stainless steel Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 20
General specifications Switching element function PNP NO/NC Rated operating distance 20 mm Installation flush mountable Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.5 Reduction factor r 304 0.6 ... 1 Mounting angle Al Amplifier housing Stainless steel Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 20