General specifications Switching element function NPN normally open contact Rated operating distance 5 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse pola
General specifications Switching element function NPN NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5%
General specifications Switching element function NPN NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5%
General specifications Switching element function PNP NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5%
General specifications Switching element function PNP NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5%
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Rev
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Rev
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Rev
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Rev
General specifications Switching element function PNP NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Rev
General specifications Switching element function PNP NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.45 Reduction factor r 304 0.7 Reduction factor r Brass 0.55 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1400 Hz Hysteresis typ. 5% Rev
General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush Output polarity DC Assured operating distance 0 ... 8.1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.38 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1000 Hz Hysteresis 1 ... 10 typ. 6 % Reverse polarity protection rever
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 400 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse pol
General specifications Switching element function AC/DC NO/NC Rated operating distance 15 mm Installation flush Output polarity AC/DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Nominal ratings Operating voltage 20 ... 253 V Operating voltage DC 20 ... 300 V Switching frequency 0 ... 25 Hz Hysteresis typ. 3 %
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 400 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Nominal ratings Installation conditions A 5 mm Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 400 Hz Hysteres
General specifications Switching element function AC/DC NO/NC Rated operating distance 15 mm Installation flush Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Nominal ratings Operating voltage DC 20 ... 300 V Operating voltage AC 20 ... 253 V Switching frequency 0 ... 25 Hz Hysteresis typ. 3 % Short-circuit protec
General specifications Switching element function NAMUR, NC Rated operating distance 2 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 2000 Hz Hysteresis typ. 5 % Current consumption Mea
General specifications Switching element function NAMUR, NC Rated operating distance 2 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 2000 Hz Hysteresis typ. 5 % Current consumption Mea
General specifications Switching element function AC/DC NO/NC Rated operating distance 20 mm Installation flush Output polarity AC/DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage DC 20 ... 300 V Operating voltage AC 20 ... 250 V Switching frequency 200 Hz VDC / 30 Hz VAC Hysteresis 3 ... 10 % Reverse polarity
General specifications Switching element function NAMUR, NC Rated operating distance 20 mm Installation flush Output polarity DC Assured operating distance 0 ... 16.2 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection r
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 80 Hz Hysteresis typ. 3 % Reverse polarity protection reverse polar
General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 32 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Installation conditions F 100 mm Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 80 Hz Hysteresis
General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 32 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Nominal ratings Installation conditions F 100 mm Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 80 Hz Hysteresis