General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 400 Hz Hysteresis 1 ... 15 typ. 5 % Reverse polarity protection reverse pol
General specifications Switching element function NPN NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Rever
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection yes Short-circuit pr
General specifications Switching element function NPN NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Rever
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Rever
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection reverse pola
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Rever
General specifications Switching element function NPN NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse
General specifications Switching element function DC NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection yes Short-circuit pr
General specifications Switching element function NAMUR, NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection yes Short-circuit pr
General specifications Switching element function NPN NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Reverse polarity protection reverse polarity protected Short-circui
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Reverse polarity protection reverse polarity protected Short-circui
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Reverse polarity protection reverse polarity protected Short-circui
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 10 % Reverse polarity protection reverse polarity p
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 10 % Reverse polarity protection reverse polarity p
General specifications Switching element function NPN NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr
General specifications Switching element function NPN NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr
General specifications Switching element function NPN NC Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr
General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.15 Reduction factor r Cu 0.1 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity p
General specifications Switching element function PNP NC Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr
General specifications Switching element function DC NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.18 Reduction factor r Cu 0.12 Reduction factor r 304 0.67 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 1000 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reverse
General specifications Switching element function DC NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.18 Reduction factor r Cu 0.12 Reduction factor r 304 0.67 Nominal ratings Operating voltage 5 ... 60 V DC Switching frequency 0 ... 1000 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection rever
General specifications Switching element function DC NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 1.52 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.18 Reduction factor r Cu 0.12 Reduction factor r 304 0.67 Nominal ratings Operating voltage 5 ... 60 V Switching frequenc