General specifications Switching element function AC NO Rated operating distance 15 mm Installation quasi flush Output polarity AC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.28 Reduction factor r 304 0.81 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 5 % Voltage drop < 5 V (I L > 50 mA)-
General specifications Switching element function NPN NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Short-c
General specifications Switching element function NPN NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Short-c
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Reverse polarity protection reverse polarity protected Short-c
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 11.4 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching fre
General specifications Switching element function NO/NC programmable Rated operating distance 15 mm Installation flush Output polarity AS-Interface Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Reduction factor r Brass 0.5 Slave type A/B slave AS-Interface specification V3.0 Required master specification greater or eq
General specifications Switching element function 1 electronic relay, N.C. Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Reduction factor r Brass 0.5 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 30 Hz Hysteresis 2 ...
General specifications Switching element function 1 electronic relay, N.O. Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Reduction factor r Brass 0.5 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 30 Hz Hysteresis 2 ...
General specifications Switching element function NPN NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Reduction factor r Brass 0.5 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 30 Hz Hysteresis 2 ... 20 % ( typ. 1
General specifications Switching element function NPN NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Reduction factor r Brass 0.5 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 30 Hz Hysteresis 2 ... 20 % ( typ. 1
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Reduction factor r Brass 0.5 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 30 Hz Hysteresis 2 ... 20 % ( typ. 3
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.8 Reduction factor r Brass 0.5 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 30 Hz Hysteresis 2 ... 20 % ( typ. 3
General specifications Switching element function NPN NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Rever
General specifications Switching element function NPN NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.34 Reduction factor r Cu 0.32 Reduction factor r 304 0.77 Reduction factor r Brass 0.43 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function NPN NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection reverse pola
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Rever
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.34 Reduction factor r Cu 0.32 Reduction factor r 304 0.77 Reduction factor r Brass 0.43 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reve
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection reverse pola
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.35 Reduction factor r Cu 0.3 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5 % Reverse polarity protection reverse pola
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Rever
General specifications Switching element function NPN NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse
General specifications Switching element function NPN NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 4 Hz Hysteresis typ. 5 % Reverse p
General specifications Switching element function PNP NO Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse
General specifications Switching element function PNP NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.31 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Reverse
General specifications Switching element function DC NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO/NC Rated operating distance 15 mm Installation flush Output polarity DC Assured operating distance 0 ... 12.15 mm Reduction factor r Al 0.33 Reduction factor r Cu 0.3 Reduction factor r 304 0.74 Reduction factor r Brass 0.41 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 200 Hz Hysteresis typ. 5 % Rever