General specifications Switching element function AC NO Rated operating distance 4 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Voltage drop typ. 4 V at 15 ... 200 mA typ. 6.5 V at 5 mA Momenta
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation flush Output polarity NAMUR Assured operating distance 0 ... 3.04 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 1000 Hz Hysteresis typ. % Suitable for 2:1 technology ye
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation non-flush Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.8 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 2000 Hz Hysteresis typ. % Current consumption Measuring plate not detecte
General specifications Switching element function NPN NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection r
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection r
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 300 Hz Hysteresis typ. 3 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 300 Hz Hysteresis typ. 3 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection r
General specifications Switching element function NPN NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reve
General specifications Switching element function NPN NC Rated operating distance 40 mm Installation non-flush Output polarity switched low Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protec
General specifications Switching element function PNP NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reve
General specifications Switching element function PNP NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 10 Hz Hysteresis typ. 3 % Reverse polarity protection reverse polari
General specifications Switching element function PNP NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reve
General specifications Switching element function PNP NC Rated operating distance 40 mm Installation non-flush Output polarity switched high Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity prote
General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 100 Hz Current consumption Measuring plate not de
General specifications Switching element function AC NO/NC Rated operating distance 40 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop less than or
General specifications Switching element function AC NO/NC Rated operating distance 40 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop 4 V Momentary
General specifications Switching element function PNP NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reve
General specifications Switching element function NPN NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection y
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V DC Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection
General specifications Switching element function NPN NO Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection yes
General specifications Switching element function PNP NO contact Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 100 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection
General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 100 Hz Current consumption Measuring plate not de
General specifications Switching element function AC NO/NC Rated operating distance 40 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 30.6 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Operating voltage 20 ... 253 V 1) Switching frequency 0 ... 25 Hz Hysteresis typ. 3 % Voltage drop less than or equal to
General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation non-flush Output polarity Safety Function Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Safety Integrity Level (SIL) up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualifi
General specifications Switching element function NAMUR, NC Rated operating distance 40 mm Installation non-flush Output polarity Safety Function Assured operating distance 0 ... 32.4 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 100 Hz Current consumption Measuring plate not detected min.
General specifications Switching element function PNP NO/NC Rated operating distance 40 mm Installation non-flush Output polarity DC Assured operating distance 1 ... 32.4 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r St37 0 Reduction factor r Brass 1 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis 3 ... 10 % Reverse po
General specifications Switching element function NAMUR, NC Rated operating distance 5 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 3000 Hz Hysteresis typ. % Suitable for 2:1 technology
General specifications Switching element function NAMUR, NC Rated operating distance 5 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 3000 Hz Hysteresis typ. % Suitable for 2:1 technology yes , Reverse polarit