General specifications Switching element function AC NO/NC Rated operating distance 30 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop less than or equa
General specifications Switching element function AC NO/NC Rated operating distance 30 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 24.3 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage AC 20 ... 253 V 1) Switching frequency 0 ... 20 Hz Hysteresis 1 ... 10 typ. 5 % Voltage drop less than
General specifications Switching element function NAMUR, NO Rated operating distance 30 mm Installation non-flush Output polarity NAMUR Assured operating distance 1 ... 24.3 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r St37 0 Reduction factor r Brass 1 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 150 Hz Current consumption Measuring plate no
General specifications Switching element function PNP NO/NC Rated operating distance 30 mm Installation non-flush Output polarity Selective Assured operating distance 1 ... 24.3 mm Reduction factor r Al 1 Reduction factor r Cu 1 Reduction factor r St37 0 Reduction factor r Brass 1 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 150 Hz Hysteresis typ. 5 % Rever
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 1500 Hz Current consumption Measuring plate not de
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 1500 Hz Current consumption Measuring plate not detected min. 3 mA
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 1500 Hz Current consumption Measuring plate not detected min. 3 mA
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation non-flush Output polarity Safety Function Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Safety Integrity Level (SIL) up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualifie
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation non-flush Output polarity Safety Function Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Safety Integrity Level (SIL) up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualifie
General specifications Switching element function NPN NO Rated operating distance 4 mm Installation non-flush Output polarity switched low Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity prot
General specifications Switching element function NPN NC Rated operating distance 4 mm Installation non-flush Output polarity switched low Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity prot
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity switched high Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity pro
General specifications Switching element function PNP NC Rated operating distance 4 mm Installation non-flush Output polarity switched high Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity pro
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Switching frequency 0 ... 1500 Hz Hysteresis 3 % Current consumption Mea
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 1500 Hz Current consumption Measuring plate not detected min. 3 mA
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 1500 Hz Current consumption Measuring plate not detected min. 3 mA
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8 V Switching frequency 0 ... 1500 Hz Current consumption Measuring plate not detected min. 3 mA
General specifications Switching element function NAMUR, NC Rated operating distance 4 mm Installation non-flush Output polarity NAMUR Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.85 Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Operating voltage 5 ... 25 V Switching frequency 0 ... 1500 Hz Hysteresis 3 %
General specifications Switching element function NPN NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity protection re
General specifications Switching element function NPN NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity protection re
General specifications Switching element function NPN NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity protection re
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity protection re
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity protection re
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity protection re
General specifications Switching element function PNP NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity protection re
General specifications Switching element function PNP NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 2000 Hz Hysteresis 1 ... 10 typ. 3 % Reverse polarity protection rev
General specifications Switching element function AC NC Rated operating distance 4 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Reverse polarity protection reverse polarity tolerant Voltage dro
General specifications Switching element function AC NC Rated operating distance 4 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Voltage drop typ. 4 V at 15 ... 200 mA typ. 6.5 V at 5 mA Momenta
General specifications Switching element function AC NO Rated operating distance 4 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Reverse polarity protection reverse polarity tolerant Voltage dro
General specifications Switching element function AC NO Rated operating distance 4 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Voltage drop typ. 4 V at 15 ... 200 mA typ. 6.5 V at 5 mA Momenta