PEPPERL+FUCHS - Proximity inductive sensors

Image
Part Number
Description
General specifications Switching element function NPN NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 3000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.65 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1800 Hz Hysteresis typ. 5% Reverse polarity protection reverse pol
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.65 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1800 Hz Hysteresis typ. 5 % Reverse polarity protection reverse po
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Reverse polarity protection reverse polarity protected Short-
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 3000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function PNP NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 3000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function PNP NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 3000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function DC NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.21 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.16 Reduction factor r 304 0.64 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 1200 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection revers
General specifications Switching element function DC NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.21 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.16 Reduction factor r 304 0.64 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 1200 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection revers
General specifications Switching element function NPN NO/NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function NPN NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Reverse polarity protection reverse polarity protected Short-
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Reverse polarity protection reverse polarity protected Short-
General specifications Switching element function DC NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.21 mm Reduction factor r Al 0.22 Reduction factor r Cu 0.16 Reduction factor r 304 0.64 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 1200 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection revers
General specifications Switching element function NPN NO/NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.2 Reduction factor r 304 0.8 Reduction factor r Brass 0.45 Nominal ratings Operating
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 8 mm x 8 mm x 1 mm Reduction factor r Al 0.38 Reduction factor r Cu 0.2 Reduction factor r 304 0.8 Reduction factor r Brass 0.45 Nominal ratings Operating
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 3 % Reverse polarity protection reverse p
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 3 % Reverse polarity protection reverse p
General specifications Switching element function PNP NC Rated operating distance 1.5 mm Installation flush Output polarity switched high Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 3 % Reverse polarity protection
General specifications Switching element function PNP NC Rated operating distance 1.5 mm Installation flush Output polarity switched high Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 3 % Reverse polarity protection
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 3 % Reverse polarity protection reverse p
General specifications Switching element function PNP NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 3 % Reverse polarity protection reverse p
General specifications Switching element function PNP NC Rated operating distance 1.5 mm Installation flush Output polarity switched high Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 3 % Reverse polarity protection
General specifications Switching element function PNP NC Rated operating distance 1.5 mm Installation flush Output polarity switched high Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.35 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1500 Hz Hysteresis typ. 3 % Reverse polarity protection
General specifications Switching element function NPN NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 30 V DC Switching frequency 0 ... 1200 Hz Hysteresis typ. 5 % Short-circuit protection pulsing Volta
General specifications Switching element function NPN NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 30 V DC Switching frequency 0 ... 1200 Hz Hysteresis typ. 5 % Short-circuit protection pulsing Volta
General specifications Switching element function NPN NO Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 30 V DC Switching frequency 0 ... 1200 Hz Hysteresis typ. 5 % Short-circuit protection pulsing Volta
General specifications Switching element function NPN NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 30 V Switching frequency 0 ... 1200 Hz Hysteresis typ. 5 % Reverse polarity protection no Short-circ
Menu
Mail Us
enquiry@onstocktrading.com