General specifications Switching element function NPN NC Rated operating distance 1.5 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.215 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.7 Nominal ratings Operating voltage 5 ... 30 V Switching frequency 0 ... 1200 Hz Hysteresis typ. 5 % Reverse polarity protection no Short-circuit protection pulsing Voltage drop less than or equal to 1.5 V Operating current 0 ... 100 mA Off-state current less than or equal to 10 mA No-load supply current less than or equal to 15 mA Functional safety related parameters MTTF d 3910 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Approvals and certificates UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated less than or equal to 36 V Ambient conditions Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Mechanical specifications Connection type Solder connection PVC , 500 mm Core cross-section 0.08 mm 2 Housing material PA Sensing face PA Housing diameter Degree of protection IP67