PEPPERL+FUCHS - Proximity inductive sensors

Image
Part Number
Description
PPRL_no_foto.jpg
PPRL_no_foto.jpg
General specifications Switching element function NPN NO/NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO/NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO/NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function NPN NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function NPN NO/NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO/NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function NPN NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity pr
General specifications Switching element function NPN NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function NPN NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Reverse polarity protection reverse polarity protected Short-circ
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 500 Hz Reverse polarity protection reverse polarity protected Short-circ
General specifications Switching element function NO/NC programmable Rated operating distance 6 mm Installation flush Output polarity AS-Interface Assured operating distance 0 ... 4.86 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Slave type Standard slave AS-Interface specification V2.1 Required master specification greater or equal V2.1 Nominal ratings
General specifications Switching element function NO/NC programmable Rated operating distance 6 mm Installation flush Output polarity AS-Interface Assured operating distance 0 ... 4.86 mm Reduction factor r Al 0.28 Reduction factor r Cu 0.25 Reduction factor r 304 0.75 Slave type A/B slave AS-Interface specification V3.0 Required master specification greater or equal V2.1 Nominal ratings Op
General specifications Switching element function PNP NO Rated operating distance 7 mm Installation flush Output polarity DC Assured operating distance 0 ... 5.67 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 500 Hz Hysteresis typ. 5% Reverse polarity protection yes Short-circuit prote
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 6.08 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequenc
General specifications Switching element function PNP NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr
General specifications Switching element function PNP NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 6.08 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequenc
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function NPN NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function NPN NC Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity p
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pr