Image
Part Number
Description
General specifications Switching element function NPN NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pro
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pro
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r St37 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polarity p
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 800 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 18 mm x 18 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 18 mm x 18 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 3.8 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 18 mm x 18 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function PNP NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pro
General specifications Switching element function PNP NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 18 mm x 18 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function PNP NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarity pro
General specifications Switching element function PNP NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 18 mm x 18 mm x 1 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.4 Nominal ratings Installation
General specifications Switching element function NPN NO/NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.66 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function NPN NO/NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.66 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Reverse polarity protection reverse polarity protected Short-c
General specifications Switching element function NPN NO/NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.66 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function PNP NO/NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.66 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function PNP NO/NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.66 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Reverse polarity protection reverse polarity protected Short-c
General specifications Switching element function PNP NO/NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.66 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function PNP NO/NC Rated operating distance 5 mm Installation flush Output polarity DC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.15 Reduction factor r 304 0.66 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 800 Hz Reverse polarity protection reverse polarity protected Shor
General specifications Switching element function Analog current output Installation flush Output polarity DC Measurement range 1 ... 5 mm Nominal ratings Operating voltage 10 ... 30 V Repeat accuracy 0 ... 20 mm No-load supply current less than or equal to 12 mA Analog output Output type 4 ... 20 mA Linearity error less than or equal to ± 4 % of full-scale value Load resistor less than or equal to 1
General specifications Switching element function Analog current output Installation flush Output polarity DC Measurement range 1 ... 5 mm Nominal ratings Operating voltage 10 ... 30 V Repeat accuracy 0 ... 20 mm No-load supply current less than or equal to 12 mA Analog output Output type 4 ... 20 mA Linearity error less than or equal to ± 4 % of full-scale value Load resistor less than or equal to 1
General specifications Switching element function Analog current output Installation flush Output polarity DC Measurement range 1 ... 5 mm Nominal ratings Operating voltage 10 ... 30 V Repeat accuracy 0 ... 20 mm No-load supply current less than or equal to 12 mA Analog output Output type 0 ... 20 mA Linearity error less than or equal to ± 4 % of full-scale value Load resistor less than or equal to 1
General specifications Switching element function Analog current output Installation flush Output polarity DC Measurement range 1 ... 5 mm Nominal ratings Operating voltage 10 ... 30 V Repeat accuracy 0 ... 20 mm No-load supply current less than or equal to 12 mA Analog output Output type 0 ... 20 mA Linearity error less than or equal to ± 4 % of full-scale value Load resistor less than or equal to 1
General specifications Switching element function AC NC Rated operating distance 5 mm Installation flush Output polarity AC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 6 % Reverse polarity protection reverse polarity tol
PPRL_no_foto.jpg
General specifications Switching element function AC NO Rated operating distance 5 mm Installation flush Output polarity AC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 6 % Reverse polarity protection reverse polarity tol
General specifications Switching element function AC NO Rated operating distance 5 mm Installation flush Output polarity AC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 6 % Voltage drop < 5 V (I L > 50 mA)- < 8 V (I L
General specifications Switching element function AC NO Rated operating distance 5 mm Installation flush Output polarity AC Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.2 Reduction factor r Cu 0.2 Reduction factor r 304 0.6 Nominal ratings Operating voltage 20 ... 253 V Switching frequency 0 ... 20 Hz Hysteresis typ. 6 % Reverse polarity protection yes Short-circuit
PPRL_no_foto.jpg
General specifications Switching element function PNP NO Rated operating distance 5 mm Installation flush Assured operating distance 0 ... 4.05 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Reduction factor r St37 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Reverse polarity protection reverse polarity protected Short