General specifications Switching element function NPN NO/NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function NPN NO/NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1000 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Reduction factor r Brass 0.5 Nominal ratings Installa
General specifications Switching element function AC NC Rated operating distance 4 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 20 ... 150 V Switching frequency 0 ... 25 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection reverse
General specifications Switching element function AC NO Rated operating distance 4 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.4 Reduction factor r 304 0.7 Nominal ratings Operating voltage 20 ... 150 V Switching frequency 0 ... 25 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection reverse
General specifications Switching element function AC NO Rated operating distance 4 mm Installation non-flush Output polarity AC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 20 ... 150 V Switching frequency 0 ... 25 Hz Voltage drop less than or equal to 6.5 V Operating current 5 ...
General specifications Switching element function PNP NO Rated operating distance 7 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 5.67 mm Reduction factor r Al 0.48 Reduction factor r Cu 0.45 Reduction factor r 304 0.72 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5% Reverse polarity protection reverse polar
General specifications Switching element function PNP NO Rated operating distance 7 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 5.67 mm Reduction factor r Al 0.48 Reduction factor r Cu 0.45 Reduction factor r 304 0.72 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5% Reverse polarity protection reverse polar
General specifications Switching element function PNP NC Rated operating distance 7 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 5.67 mm Reduction factor r Al 0.48 Reduction factor r Cu 0.45 Reduction factor r 304 0.72 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 300 Hz Hysteresis typ. 5% Reverse polarity protection reverse polar
General specifications Switching element function NPN NO Rated operating distance 7 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 5.67 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO Rated operating distance 7 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 5.67 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NC Rated operating distance 7 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 5.67 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function NPN NO Rated operating distance 7 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 5.67 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function NPN NC Rated operating distance 7 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 5.67 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO Rated operating distance 7 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 5.67 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NC Rated operating distance 7 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 5.67 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 60 V Switching frequency 0 ... 400 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polar
General specifications Switching element function NPN NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function NPN NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function PNP NO/NC Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.35 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse po
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.45 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function NPN NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.45 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm Reduction factor r Al 0.39 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.45 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse
General specifications Switching element function PNP NO Rated operating distance 8 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 6.48 mm ( -25 ... 70 °C (-13 ... 158 °F) ) 0 ... 6.08 mm ( -40 ... -25 °C (-40 ... -13 °F) ) Reduction factor r Al 0.39 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Reduction factor r Brass 0.45 Nominal ratings Operating vo
General specifications Switching element function AC/DC NO Rated operating distance 8 mm Installation non-flush Output polarity AC/DC NO contact Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.75 Nominal ratings Operating voltage 20 ... 250 V AC/20 ... 300 V DC Switching frequency 30 Hz Hysteresis 3 ... 15 typ. 5 % Reverse polarity protection reverse polarity tol