General specifications Switching element function PNP NO Rated operating distance 3 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.5 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 2000 Hz Reverse polarity protection reverse polarity protected Short-c
General specifications Switching element function PNP NO Rated operating distance 3 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.5 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 2000 Hz Hysteresis typ. 8 % Reverse polarity protection reverse polar
General specifications Switching element function PNP NO Rated operating distance 3 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.3 Reduction factor r Cu 0.25 Reduction factor r 304 0.65 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 50 Hz Hysteresis typ. 5 % Reverse polarity protection reverse pol
General specifications Switching element function PNP NO Rated operating distance 3 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.5 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 2000 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function PNP NO Rated operating distance 3 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.5 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 2000 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function NPN NO Rated operating distance 3 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 2.43 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.45 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5% Reverse polarity protection reverse polar
General specifications Switching element function NPN NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.9 Reduction factor r Brass 0.6 Nominal ratings Installa
General specifications Switching element function PNP NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.9 Reduction factor r Brass 0.6 Nominal ratings Installa
General specifications Switching element function NPN NO/NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Reverse polarity protection reverse polarity protected Shor
General specifications Switching element function PNP NO/NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Reverse polarity protection reverse polarity protected Shor
General specifications Switching element function NPN NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis 3 ... 10 typ. % Reverse polarity protection revers
General specifications Switching element function NPN NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polar
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 800 Hz Hysteresis typ. 5% Reverse polarity protection reverse polari
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Actuating element mild steel, e. g. 1.0037, SR235JR (formerly St37-2) 12 mm x 12 mm x 1 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Reduction factor r Brass 0.5 Nominal ratings Installa
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.45 Reduction factor r Cu 0.4 Reduction factor r 304 0.75 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polar
General specifications Switching element function DC NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 1000 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reve
General specifications Switching element function DC NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 1000 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reve
General specifications Switching element function DC NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.37 Reduction factor r Cu 0.36 Reduction factor r 304 0.74 Nominal ratings Operating voltage 5 ... 60 V Switching frequency 0 ... 1000 Hz Hysteresis 1 ... 10 typ. 5 % Reverse polarity protection reve
General specifications Switching element function NPN NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function NPN NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function NPN NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Hysteresis typ. 5% Reverse polarity protection reverse polarit
General specifications Switching element function NPN NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.4 Reduction factor r Cu 0.3 Reduction factor r 304 0.7 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 1200 Hz Hysteresis typ. 5% Reverse polarity protection reverse pola
General specifications Switching element function PNP NO Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function PNP NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Reverse polarity protection reverse polarity protected Short-ci
General specifications Switching element function PNP NC Rated operating distance 4 mm Installation non-flush Output polarity DC Assured operating distance 0 ... 3.24 mm Reduction factor r Al 0.5 Reduction factor r Cu 0.4 Reduction factor r 304 0.8 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1200 Hz Reverse polarity protection reverse polarity protected Short-ci