Protection DIN EN 60529 IP 65 Transformation ratio 0.5 ±5 % Connection Connector M23 type 2, 12-pin manufacter SKU RTD 1 B14 Y 1 Starting torque ≤0.01 Nm (+20 °C) Interference immunity DIN EN 61000-6-2 Operating temperature -20...+100 °C Resistance DIN EN 60068-2-6 Vibration 20 g, 60-2000 Hz DIN EN 60068-2-27 Shock 100 g, 11 ms Operating speed ≤10000 rpm Admitted shaft load ≤20 N
Weight approx. 310 g Size (flange) ø58 mm Resistance DIN EN 60068-2-6 Vibration 20 g, 60-2000 Hz DIN EN 60068-2-27 Shock 100 g, 11 ms manufacter SKU RTD 1 B14 Y 3 Number of pole pairs 1 = 2 poles Interference immunity DIN EN 61000-6-2 Materials Housing: aluminium, black, powder-coated Shaft: stainless steel Operating temperature -40...+100 °C Starting torque ≤0.01 Nm (+20 °C) Prote
manufacter SKU RTD 4 A 4 Y 2 Mounting kit 050 Motor shaft tolerance 0.25 mm axial 0.1 mm radial Number of pole pairs 1 = 2 poles Operating speed ≤8000 rpm Weight approx. 670 g Starting torque ≤0.015 Nm (+20 °C) Shaft type ø10...16 mm (blind hollow shaft) Phase shift 0° ±10° Protection DIN EN 60529 IP 65 Connection Connector M23 type 2, 12-pin Interference immunity
Operating temperature -30...+130 °C Climatic test Humid heat, constant (IEC 60068-2-3, Ca) Protection DIN EN 60529 IP 56 Isolation class B Admitted shaft load ≤40 N axial ≤60 N radial Emitted interference EN 61000-6-3 Torque 1.5 Ncm Rotor moment of inertia 0.25 kgcm² manufacter SKU TDP 0,09 Approval CE Linearity tolerance ≤0.15 % Connection Terminal box Calibrat
Connection 2x terminal box Minimum switching current 100 mA Size (flange) ø115 mm Switching hysteresis =30 % of switching speed Materials Housing: aluminium die-cast Shaft: stainless steel Open-circuit voltage 10...150 mV per rpm Weight approx. 3.2 kg Isolation class B Switching delay time ≤40 ms Temperature coefficient ±0.05 %/K (open-circuit) Switching outputs 1 output, sp
Switching outputs 3 outputs, speed control Calibration tolerance ±1 % Consumption w/o load ≤5 mA Materials Housing: aluminium die-cast Shaft: stainless steel Speed (n) ≤5000 rpm Size (flange) ø115 mm Flange EURO flange B10 Isolation class B Performance 12 W (speed ≥3000 rpm) Rotor moment of inertia 1.4 kgcm² Current each output 40 mA (DC) Voltage supply 12 V
Weight approx. 3.1 kg Range of switching speed (ns) 850...4500 rpm (Δn = 2 rpm/s) Isolation class B Minimum switching current 50 mA Performance 12 W (speed ≥3000 rpm) Climatic test Humid heat, constant (IEC 60068-2-3, Ca) Flange EURO flange B10 Interference immunity EN 61000-6-2 Emitted interference EN 61000-6-3 Temperature coefficient ±0.05 %/K (open-circuit) Approval CE
Linearity tolerance ≤0.15 % Scan ratio 40...60 % Rotor moment of inertia 1.4 kgcm² Operating speed ≤10000 rpm Reversal tolerance ≤0.1 % Armature-circuit time-constant Reference signal Zero pulse, width 90° Operating temperature -30...+100 °C -25...+100 °C (>3072 pulses per revolution) Admitted shaft load ≤60 N axial ≤80 N radial Materials Housing: aluminium die-cast S
Baumer Hubner tachogenerator TDP 0,2 LT-1 B10 55. The main purpose of Baumer tachogenerator is measurement of the direction of rotation and speed via voltage output signal. The rate of this voltage corresponds to the speed of rotation of the shaft. MAIN FEATURES BAUMER HUBNER TDP0,2LT-4B10 55: ø 11 mm Protection: Up to IP55.. Open-circuit voltage: 150 mV per rpm. Linearity tolerance: ≤0.15 %. Reversal tolerance: ≤0.1 %. Operating
Emitted interference EN 61000-6-3 Approval CE Linearity tolerance ≤0.15 % Reversal tolerance ≤0.1 % Protection DIN EN 60529 IP 55 Temperature coefficient ±0.05 %/K (open-circuit) Climatic test Humid heat, constant (IEC 60068-2-3, Ca) Admitted shaft load ≤80 N axial ≤100 N radial Size (flange) ø120 mm ø165 mm ø175 mm manufacter SKU TDP 13 Calibration toler
Tachogenerators TDP 13 Low response time Open circuit voltage 20...200 mV per rpm Solid shaft ø14...18 mm with flange High signal quality due to patented LongLife technology With own bearings No auxiliary energy source required
Tachogenerators TDP 13 Low response time Open circuit voltage 20...200 mV per rpm Solid shaft ø14...18 mm with flange High signal quality due to patented LongLife technology With own bearings No auxiliary energy source required
Baumer Hubner tachogenerator TDP 0,2 LT-4 B10 55. MAIN FEATURES BAUMER HUBNER TDP0,2LT-4B10 55: ø 115 mm Up to IP55 protection. Open-circuit voltage: 60 mV per rpm. Reversal tolerance: ≤0.1 %. Linearity tolerance: ≤0.15 %. Operating temperature: -30...+130 °C. Double silver track. Euro Flange. Easy access to the terminals by a reversible terminal box. Maintenance-free during the life time of the ball bearings. Speed and directio
Protection DIN EN 60529 IP 56 Operating temperature -30...+130 °C Climatic test Humid heat, constant (IEC 60068-2-3, Ca) Admitted shaft load ≤40 N axial ≤60 N radial Emitted interference EN 61000-6-3 Torque 1.5 Ncm Armature-circuit time-constant Rotor moment of inertia 0.29 kgcm² Weight approx. 1.5 kg Linearity tolerance ≤0.15 % Interference immunity EN 61000-6-2 O
Interference immunity EN 61000-6-2 Materials Housing: aluminium die-cast Shaft: stainless steel Isolation class B Protection DIN EN 60529 IP 55 Consumption w/o load ≤100 mA Scan ratio 40...60 % Approval CE Climatic test Humid heat, constant (IEC 60068-2-3, Ca) Torque 1.5 Ncm Phase shift 90° ±20° Size (flange) ø115 mm Linearity tolerance ≤0.15 % Open-circuit v
Isolation class B Climatic test Humid heat, constant (IEC 60068-2-3, Ca) Resistance IEC 60068-2-6 Vibration 10 g, 10-2000 Hz IEC 60068-2-27 Shock 100 g, 6 ms Interference immunity EN 61000-6-2 Operating temperature -30...+130 °C Reversal tolerance ≤0.1 % Operating speed ≤6000 rpm Armature-circuit time-constant Protection DIN EN 60529 IP 55 Size (flange) ø120 mm ø165
Size (flange) 60 x 72 mm Consumption w/o load ≤85 mA Pulses per revolution 100...2048 Protection DIN EN 60529 IP 54 manufacter SKU TIL Operating speed ≤6000 rpm Reference signal Zero pulse, width 90° Reverse polarity protection Yes Output frequency ≤120 kHz Motor shaft tolerance 0.25 mm axial 0.1 mm radial Materials Housing: aluminium Shaft: stainless steel Operating temper
Shaft type ø12 mm (blind hollow shaft) Emitted interference DIN EN 61000-6-3 Protection DIN EN 60529 IP 65 Motor shaft tolerance 0.25 mm axial 0.1 mm radial TIL Y 1 output signals A, B, N + inverted Starting torque ≤0.01 Nm (+20 °C) Relative humidity 90 % non-condensing Reference signal Zero pulse, width 90° Reverse polarity protection Yes Connection Cable 0.6 m Interference
Voltage supply 10...30 VDC Reverse polarity protection Yes Number of turns ≤16384 / 14 bit Sensing method Optical Transmission rate 10...1000 kBaud Connection Cable 2 m (other length upon request) Emitted interference DIN EN 61000-6-4 Size (flange) ø70 mm Interference immunity DIN EN 61000-6-2 Code sequence CW/CCW programmable Function Multiturn Interface CANopen®