Approval CE Output stages HTL TTL/RS422 Protection DIN EN 60529 IP 66 Switching accuracy ±4 % (Δn = 2 rpm/s); = +20 % (Δn = 1500 rpm/s) POG 90 + FSL output signals K1, K2, K0 + inverted Switching deviation cw-ccw rotation ≤3 % Range of switching speed (ns) 850...4500 rpm (Δn = 2 rpm/s) Interference immunity EN 61000-6-2 Consumption w/o load ≤100 mA Emitted interference EN 61000-6-3 Voltage supply 9...30 VDC 5 VDC ±5 % Switching hysteresis ~40 % of switching speed Pulses per revolution 1024...10000 Connection 2x terminal box Size (flange) ø115 mm Scan ratio 44...56 % Output frequency ≤250 kHz Reference signal Zero pulse, width 90° Rotor moment of inertia 320 gcm² Operating torque typ. 3 Ncm Shaft type ø11 mm solid shaft Resistance IEC 60068-2-6 Vibration 5 g, 10-2000 Hz IEC 60068-2-27 Shock 50 g, 11 ms Phase shift 90° ±8° Weight approx. 2.6 kg Flange EURO flange B10 Sensing method Optical Switching outputs 1 output, speed control Speed (n) ≤1.25 · ns Minimum switching current 50 mA Operating temperature -20...+85 °C manufacter SKU POG 90 + FSL Materials Housing: aluminium die-cast Shaft: stainless steel Admitted shaft load ≤250 N axial ≤350 N radial Output switching capacity ≤6 A / 230 VAC ≤1 A / 125 VDC