White Rodgers

Image
Part Number
Description
Electric Heat Sequencer, 2 Switches. On Timings, 1-20 Sec. Off Timings, 40-110 Sec.
Electric Heat Sequencer, 1 Switch. On Timings, 30-90 Sec. Off Timings, 1-30 Sec.
Electric Sequencer Used In Heat Pump Air Handler Applications, 1 Switch. On Timings, 1-60 Sec. Off Timings, 75-95 Sec.
Electric Heat Sequencer, 5 Switches. On Timings, 1-160 Sec. Off Timings, 1-160 Sec.
Electric Heat Sequencer, 1 Switch. On Timings, 1-20 Sec. Off Timings, 40-110 Sec.
Level-Temp Silent Operator For Low Voltage Control Of Electric Heat, 240 VAC,60Hz Input, SPST, Normally Open 45 Second Average Time Delay, Skeleton Construction
Level-Temp Silent Operator For Low Voltage Control Of Electric Heat, 208 VAC,60Hz Input, SPST Normally Open, 45 Second Delay, Skeleton Construction (No Enclosure)
Level-Temp Silent Operator For Low Voltage Control Of Electric Heat, 240 VAC, 60Hz Input, DPST, Normally Open 45 Second Average Time Delay
Level-Temp Silent Operator For Low Voltage Control Of Electric Heat, 277 VAC, 60Hz Input, SPST, Normally Open, 45 Second Delay
Level-Temp Silent Operator For Low Voltage Control Of Electric Heat, 208 VAC, 60Hz Input, SPST Normally Open, 45 Second Delay
Level-Temp Silent Operator For Low Voltage Control Of Electric Heat, 120 VAC, 60Hz Input, SPST Normally Open, 45 Second Delay
Level-Temp Silent Operator For Low Voltage Control Of Electric Heat, 240 VAC, 60Hz Input, SPST, Normally Open, 45 Second Average Time Delay
Line Voltage, SPST, Open On Rise Temperature Control, 20F To 120F Range, Adjustable Differential 3F To 30F, 8' Capillary
Universal Humidistat (Horizontal) For All White-Rodgers Humidifiers, 30 VAC, 60 VA. Open On Rise, 10% to 60% RH Range, 5% RH Differential (replaces SEH-7100-000)
Universal Two Stage Hot Surface Ignition Variable Speed (ECM) Circulator Furnace Control Replacement Kit. Replaces All WR 50V51-xxx's and 50V61-xxx's Two-Stage H.S.I. Systems with 80v or 120v Ignitors. Includes 21D64-2 Ignitor
Universal Two Stage Hot Surface Ignition Control, 3 Speed (PSC) Circulator Furnace Control Kit. Replaces WR 50M51-242 and all 50M61-xxx's Two-Stage H.S.I. Systems with 80v or 120v Ignitors. Includes 21D64-2 Ignitor
NEW-Replacement Kit for Lennox & White-Rodgers single stage, Nitride ignition, integrated furnace Modules
NEW-HotRod 5-Pack contains 5 single Pack Ignitor Kits (21D64-2)
Universal 120V Silicon Nitride Upgrade Kit for Conversion of silicon carbide (flat or spiral) includes, 2 brackets, Furnace label, instruction booklet, and 2 ceramic wire nuts. 3 Year Warranty. Replaces over 140 Silicon Carbide Ignitor types, also Replaces Honeywell Glowfly.
Evap. Cool. Ctl Sys. Incl. 1F51N-619 Wall T-Stat And 8A18Z-2 Trans-Stat-Stat: 55F To 95F Range, Horiz. Mount, Cooling. Antic., Subbase/Sys. Sw: Off-Cool-Vent And Fan Sw: Hi-Lo.
Line Voltage, SPST, Close On Rise Temperature Control, Coiled Bulb, 20F To90F Range, Adjustable Differential 3F To 20F
Line Voltage, SPST, Close On Rise Temperature Control, Nickel Plated Coiled Bulb, -30F To +90F Range, Adjustable Differential 3F To 20F
NEW - Emerson Inspire Universal 4-Wire Thermostat System (4H/2C) controls single stage, multi-stage, heat-pump and heat pump with dual fuel plus humidification /dehumidification, 7-day, 5-2, or non-programmable, auto changeover, dual fuel requires outdoor sensor F145-1378, System Switch-Heat /Off /Cool /Emergency/Auto, Fan Switch-Auto/On, EMR, Profile-Horizontal, Range 45-99 F. Module Terminals: RC, RH, C, W/E, W2, Y, Y2, G, O/B, L, +, S, -, HM,
Line Voltage Thermostat, Mechanical Bimetal, DPST, Open on Rise, 40 to 80, No Thermometer, with "Off" Position, Classic White Color, Wallplate Included.
Line Voltage Thermostat, Mechanical Bimetal, SPST, Open on Rise, 40 to 80, No Thermometer, Classic White Color, Wallplate Included.
Emerson Blue Wireless Easy Install 6" Display, Universal Single Stage, Multi-Stage, Heat-Pump up to (4H/2C), With Humidification / Dehum, 7-Day Program, Backlit, Auto Changeover, Dual Fuel (Requires Sensor Below), System Switch-Heat, Off, Cool, Emergency, Auto, Fan Switch- Auto, On, EMR, Keypad Lockout, Profile-Horizontal, Range 45-99 F., Module Terminals, RC,RH,C,G,Y,Y2,W/E,W2,O/B,L,DHM,DHM2,HM,HM2. Compatible with F145RF-1600 Indoor/Outdoor Wir
Emerson Blue Easy Install 12" Touchscreen 4 Wire Communicating System with F145-1378 Outdoor Sensor included. Universal Single Stage, Multi-Stage Or Heat-Pump up to (4H/2C), With Humidification and/or Dehum, Dual Fuel Option, 7-Day Programmable, Backlit, 24 Volt, Auto Changeover, System Switch-Heat, Off, Cool, Emergency, Auto, Fan Switch- Auto, On, Program Fan, EMR, Keypad Lockout, Profile-Horizontal, Hardwire, Range 45-99 F., Terminals RC,RH,C,G
Emerson Blue Easy Install 12" Touchscreen 4 Wire Communicating System. Universal Single Stage, Multi-Stage Or Heat-Pump up to (4H/2C), With Humidification and/or Dehum, Dual Fuel Option, 7-Day Programmable, Backlit, 24 Volt, Auto Changeover, System Switch-Heat, Off, Cool, Emergency, Auto, Fan Switch- Auto, On, Program Fan, Energy Management Recovery, Outdoor Sensor Option, Keypad Lockout, Profile-Horizontal, Hardwire, Range 45-99 F., Terminals RC
Emerson Big Blue 12" Display, Touchscreen Premium Universal (1H/1C)Program Choices: 7 Day, 5+1+1 Day Or Non-Programmable Digital Thermostat, Backlit Display, 24 Volt, Digital Remote Sense Option, Backlit Display, 24 Volts Or Millivolt, Auto Changeover, System Switch-Heat, Off, Cool, Auto, FanSwitch-Auto, On, Program Fan, Energy Management Recovery, Keypad Lockout, Profile-Horizontal, Dual Power with Optional "C" Connection And/Or Batteries,
Emerson Blue Easy Reader Universal Compatible Single Stage (1H/1C), Multi-Stage (2H/2C) Or Heat Pump up to (4H/2C). Program Choices: Non-Programmable or 7-Day program. Backlit Display, 24 Volts or Millivolt, System Switch-Heat, Off, Cool, Aux Heat., Fan Switch-Auto, On, Profile-Horizontal, Tri-Power (R-C) And/Or Batteries w/optional power stealing assist , Range 45-90 F. Terminals-RC,RH,C,G,W/E,W2,Y,Y2,O/B,6,L