Flow Rate Range 25 [0.5 to 25 (12.5 for CO2) в„“/min] Flow Adjustment Valve S (Yes) Port Size F01 (G1/8) Piping Entry Direction Straight Output Specification F [1 PNP Outputs + Analog (4 to 20 mA)] Unit Specification Unit Switching Function Instruction Manual With Instruction Manual Calibration Certificate None Connector Lead Wire w/Connector (2 m) Option None Made to Order None
Flow Rate Range 50 [1 to 50 (25 for CO2) в„“/min] Flow Adjustment Valve None Port Size C6 (6 One-touch Fitting) Piping Entry Direction Straight Output Specification B (2 PNP Outputs) Unit Specification Unit Switching Function Instruction Manual With Instruction Manual Calibration Certificate None Connector Lead Wire w/Connector (2 m) Option None Made to Order None
Rated Flow Range 102 (10 to 1000 l/min) Thread Type F (G) Port Size 04 (1/2) Output Specification E [1 PNP Outputs + Analog (1 to 5 V)] Connector Lead Wire w/Connector (2 m) Unit Specification Unit Switching Function Option None Calibration Certificate None
Sensor Range 3 [For Compound Pressure (-100~100kPa)] Accuracy A (В±1%F.S.) Port Size R06 (ГSMC/Sensors and switchers/Electronic pressure switches
Rated pressure range 0 to -101 kPa Piping Specification C6L (6 One-touch Fitting, Elbow Type) Output Specification N (NPN open collector 1 output) Unit With unit display switching function Option 1 G (Lead Wire w/Connector (Lead Wire Length 2m) and with connector cover) Option 2 None Option 3 Booklet Made to Order None
Rated pressure range 0 to -101 kPa Piping Specification C6L (6 One-touch Fitting, Elbow Type) Output Specification P (PNP open collector 1 output) Unit With unit display switching function Option 1 G (Lead Wire w/Connector (Lead Wire Length 2m) and with connector cover) Option 2 None Option 3 Booklet Made to Order None
Rated pressure range F (-100 to 100 kPa) Piping Specification C6H (6 One-touch Fitting, Straight Type) Output Specification E (PNP open collector 1 output + Analogue voltage output) Unit With unit display switching function Option 1 G (Lead Wire w/Connector (Lead Wire Length 2m) and with connector cover) Option 2 None Option 3 Booklet Made to Order None
Rated pressure range F (-100 to 100 kPa) Piping Specification C6H (6 One-touch Fitting, Straight Type) Output Specification F (PNP open collector 1 output + Analogue current output) Unit With unit display switching function Option 1 G (Lead Wire w/Connector (Lead Wire Length 2m) and with connector cover) Option 2 None Option 3 Booklet Made to Order None
Rated pressure range F (-100 to 100 kPa) Piping Specification C6H (6 One-touch Fitting, Straight Type) Output Specification P (PNP open collector 1 output) Unit With unit display switching function Option 1 None Option 2 B (Panel Mount) Option 3 Booklet Made to Order None
Rated pressure range F (-100 to 100 kPa) Piping Specification C6H (6 One-touch Fitting, Straight Type) Output Specification P (PNP open collector 1 output) Unit With unit display switching function Option 1 G (Lead Wire w/Connector (Lead Wire Length 2m) and with connector cover) Option 2 None Option 3 Booklet Made to Order None