Rated pressure range F (-100 to 100 kPa) Piping Specification C6H (6 One-touch Fitting, Straight Type) Output Specification E (PNP open collector 1 output + Analogue voltage output) Unit With unit display switching function Option 1 G (Lead Wire w/Connector (Lead Wire Length 2m) and with connector cover) Option 2 None Option 3 Booklet Made to Order None
Rated pressure range F (-100 to 100 kPa) Piping Specification C6H (6 One-touch Fitting, Straight Type) Output Specification F (PNP open collector 1 output + Analogue current output) Unit With unit display switching function Option 1 G (Lead Wire w/Connector (Lead Wire Length 2m) and with connector cover) Option 2 None Option 3 Booklet Made to Order None
Rated pressure range F (-100 to 100 kPa) Piping Specification C6H (6 One-touch Fitting, Straight Type) Output Specification P (PNP open collector 1 output) Unit With unit display switching function Option 1 None Option 2 B (Panel Mount) Option 3 Booklet Made to Order None
Rated pressure range F (-100 to 100 kPa) Piping Specification C6H (6 One-touch Fitting, Straight Type) Output Specification P (PNP open collector 1 output) Unit With unit display switching function Option 1 G (Lead Wire w/Connector (Lead Wire Length 2m) and with connector cover) Option 2 None Option 3 Booklet Made to Order None
Rated Pressure Range 0.0 to –101.3 kPa Piping Specifications 01 [R1/8 (With M5 Female Thread)] Output Specifications T (PNP open collector 2 outputs + Analogue voltage/Auto-shift switching) Unit Specifications With unit switching function Connector Standard Option 1 None Option 2 Operation Manual Made to Order X501 (Lead wire length 3 m)
Rated Pressure Range 0.0 to –101.3 kPa Piping Specifications C4 (4 One-touch Fitting) Output Specifications Y (PNP open collector 2 outputs + Copy function) Unit Specifications With unit switching function Connector Standard Option 1 None Option 2 Operation Manual Made to Order X501 (Lead wire length 3 m)
Rated Pressure Range 0.0 to –101.3 kPa Piping Specifications C6 (6 One-touch Fitting) Output Specifications T (PNP open collector 2 outputs + Analogue voltage/Auto-shift switching) Unit Specifications With unit switching function Connector Standard Option 1 None Option 2 Operation Manual Made to Order None
Rated Pressure Range 0.0 to –101.3 kPa Piping Specifications C6 (6 One-touch Fitting) Output Specifications Y (PNP open collector 2 outputs + Copy function) Unit Specifications With unit switching function Connector Standard Option 1 None Option 2 Operation Manual Made to Order None
Rated Pressure Range 0.0 to –101.3 kPa Piping Specifications C6 (6 One-touch Fitting) Output Specifications Y (PNP open collector 2 outputs + Copy function) Unit Specifications With unit switching function Connector Standard Option 1 None Option 2 Operation Manual Made to Order X501 (Lead wire length 3 m)
Rated Pressure Range F (–100.0 to 100 kPa) Piping Specifications WF1 (G1/8) Output Specifications S (NPN open collector 2 outputs + Analogue current/Auto-shift switching) Unit Specifications With unit switching function Connector Standard Option 1 None Option 2 Operation Manual Made to Order None