SIEMENS

Image
Part Number
Description
TIME RELAY, ELECTRONIC, WITH STAR-DELTA FUNCTION, 1 CONTACTOR DELAYED, 1 CONTACTOR NON-DELAYED, 1 TIME SET. RANGE 1...20S, 12V...240V AC/DC AT AC 50/60HZ, SCREW TERMINAL
TIME RELAY, ELECTRONIC, WITH STAR-DELTA FUNCTION, 1 CONTACTOR DELAYED, 1 CONTACTOR NON-DELAYED, 1 TIME SET. RANGE 3...60S, 12...240V AC/DC AT AC 50/60HZ, LED, SCREW TERMINAL
OUTPUT COUPLING DEVICE, RELAY COUPLER, 1 CO CONTACT 230V AC/DC WIDTH 6.2MM SCREW TERMINAL
Output coupler Relay coupler, 1 CO, 24 V DC Operating range 0.7...1.25 x US Enclosure width 6.2 mm Spring-type terminal (push-in) Thermal current 6 A
OUTPUT COUPLING DEVICE, OPTOCOUPLER 1 NO CONTACT,TRANSISTOR, 24V DC OUTPUT MAX 30V DC, 2A SHORT-CIRCUIT PROOF SPRING-TYPE TERMINALS (PUSH IN) WIDTH 6.2MM
Output coupler Optocoupler 1 NO triac, input 24 V DC Output 20-264 V AC, 2 A Overall width 6.2 mm Spring-type terminal (push-in) Thermal current 2 A
Input coupler Optocoupler 1 NO contact, transistor Input 110-230 V AC/DC Output max. 30 V DC, 0.5 A short circuit-proof Overall width 6.2 mm Spring-type terminal (push-in) thermal current 0.5 A
Output coupler with plug-in relay, 1 CO, hard gold-plated Screw terminal 24 V DC Enclosure width 6.2 mm Thermal current 6 A
OUTP. COUP. DEV. WITH PLUGGABLE RELAY, 1 NO CONTACT SPRING-TYPE TERMINALS (PUSH IN) 24V DC ENCLOSURE WIDTH 6.2 MM
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 1.6 - 16A, 50-60 HZ, 2-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SCREW CONNECTION
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 1.6 - 16A, 50-60 HZ, 2-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SCREW CONNECTION
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 1.6 - 16A, 50-60 HZ, 2-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SPRING-LOADED CONNECTION
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 1.6 - 16A, 50-60 HZ, 2-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SPRING-LOADED CONNECTION
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 4 - 40A, 50-60 HZ, 2-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SCREW CONNECTION
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 4 - 40A, 50-60 HZ, 2-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SCREW CONNECTION
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 4 - 40A, 50-60 HZ, 2-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SPRING-LOADED CONNECTION
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 BASIC, ANALOG ADJUSTABLE APPARENT CURRENT MONITORING 4 - 40A, 50-60 HZ, 2-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SPRING-LOADED CONNECTION
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S2 BASIC, ANALOG ADJUSTMENT APPARENT CURRENT MONITORING 8 - 80 A, 50-60 HZ, 2-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK WITH OR W/O ERROR LOG ON-DELAY 0-60 S SPURIOUS PEAK SUPPR.0-30 S SWITCHING HYSTERESIS 6% SCREW TERMINAL
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 1.6 - 16A, 20-400 HZ, 3-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT, 1 SEMICOND. OUTPUT FOR ALARM AND WARNING, MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 1.6 - 16A, 20-400 HZ, 3-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR. 0-30 S BREAK AFTER FAULT 0-300
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 1.6 - 16A, 20-400 HZ, 3-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR. 0-30 S BREAK AFTER FAULT 0-300 MIN
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S00 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 1.6 - 16A, 20-400 HZ, 3-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 4 - 40A, 20-400 HZ, 3-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN SCR
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 4 - 40A, 20-400 HZ, 3-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 4 - 40A, 20-400 HZ, 3-PHASE SUPPLY 24 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN SPR
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S0 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 4 - 40A, 20-400 HZ, 3-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN
MONITORING RELAY ATTACHABLE TO CONTACTOR 3RT2. SIZE S2 STANDARD, DIGITAL ADJUSTABLE APPARENT/ACTIVE CURRENT MONIT. 8 - 80A, 20-400 HZ, 3-PHASE SUPPLY 24-240 V AC/DC 1 CO CONTACT, 1 SEMICOND. FOR ALARM AND WARNING MONITORING FOR CURRENT OVERSHOOT/UNDERSHOOT PHASE FAILURE, WIRE BREAK PHASE SEQUENCE FAULT CURRENT BLOCKING CURRENT WARNING AND ALARM THRESHOLDS WITH OR W/O ERROR LOG ON-DELAY 0-99 S SPURIOUS PEAK SUPPR.0-30 S BREAK AFTER FAULT 0-300 MIN
CURRENT MONITORING RELAY MOUNTABLE ON CONT. 3RT2, SZ. S00, APPARENT/ACTIVE CURR. MONIT.1.6 - 16A, 20-400 HZ, 3-PH., SUPPLY 24 V DC, 1 CO CONTACT, MONITORING F. CURRENT OVER-/UNDERSHOOT, CURRENT ASYMMETRY, PHASE FAILURE / WIRE BREAK, PHASE SEQUENCE, FAULT CURRENT, BLOCKING CURRENT, SWITCHING CYCLE/OP. HOURS COUNTER, WARNING/ALARM THRESHOLDS, AUTO OR MANUAL RESET ON-DELAY 0-999.9 S OFF-DELAY 0-999.9 S RECLOSING DELAY 0-999.9MIN SCREW CONNECTION
CURRENT MONITORING RELAY MOUNTABLE ON CONT. 3RT2, SZ. S00, APPARENT/ACTIVE CURR. MONIT. 1.6 - 16A, 20-400 HZ, 3-PH., SUPPLY 24 V DC, 1 CO CONTACT, MONITORING F. CURRENT OVER-/UNDERSHOOT, CURRENT ASYMMETRY, PHASE FAILURE / WIRE BREAK, PHASE SEQUENCE, FAULT CURRENT, BLOCKING CURRENT, SWITCHING CYCLE/OPER. HOURS COUNTER, WARNING/ALARM THRESHOLDS, AUTO OR MANUAL RESET ON-DELAY 0-999.9 S OFF-DELAY 0-999.9 S RECLOSING DELAY 0-999.9MIN SPRING-LOADED CO
CURRENT MONITORING RELAY MOUNTABLE ON CONT. 3RT2, SZ. S0, APPARENT/ACTIVE CURR. MONIT. 4 - 40A, 20-400 HZ, 3-PH., SUPPLY 24 V DC, 1 CO CONTACT, MONITORING F. CURRENT OVER-/UNDERSHOOT, CURRENT ASYMMETRY, PHASE FAILURE / WIRE BREAK, PHASE SEQUENCE, FAULT CURRENT, BLOCKING CURRENT, SWITCHING CYCLE/OP. HOURS COUNTER, WARNING/ALARM THRESHOLDS, AUTO OR MANUAL RESET ON-DELAY 0-999.9 S OFF-DELAY 0-999.9 S RECLOSING DELAY 0-999.9MIN SCREW CONNECTION
Menu
Mail Us
enquiry@onstocktrading.com