SIEMENS

Image
Part Number
Description
FUZZYCONTROL++ IE ENABLES COMMUNICATION, LOADING OF FUNCTION BLOCKS AND ONLINE OBSERVATION USING IE
FUZZYCONTROL++ CFC ENABLES DRIVER AND CFC-PACKAGE WITH FUNCTION BLOCK (S7-400) AND FACEPLATE FROM PCS7 V5 ONWARDS
FUZZYCONTROL++OCX ACTIVEX RUNTIME MODUL
FUZZYCONTROL++OPC OPC RUNTIME MODUL
FUZZYCONTROL++ PCS 7 PCS7 RUNTIME MODULE CFC-PACKAGE WITH FUNCTION BLOCKS FOR S7-400 AND FACEPLATE FOR PCS 7 V7 SP1 HF3 AND HIGHER
TRAINING AND CONSULTING, DAILE RATE INCL. TRAVEL TIME, TRAVEL COSTS ARE NOT INCLUDED
NEUROSYSTEMS V5 D+E BASE FOR DESIGNING AND DEVELOPMENT NEURAL NETWORKS, WITH RUNTIME MODULES FOR SIMATIC S7, WINCC AND ACTIVEX
NEUROSYSTEMS OCX ACTIVEX RUNTIME MODUL
NEUROSYSTEMS OPC OPC RUNTIME MODUL
NEUROSYSTEMS PCS 7 PCS7 RUNTIME MODULE CFC-PACKAGE WITH FUNCTION BLOCKS FOR S7-400 AND FACEPLATE FOR PCS 7 V7 SP1 HF3 AND HIGHER
INDUSTR. TIME SYNCHRONISATION CENTRAL PLANT CLOCK SICLOCK TC400. STAND ALONE DEVICE.
INDUSTR. TIME SYNCHRONISATION SICLOCK BUNDLE TC400 AND GPS RADIO CLOCK CONTAINS: CENTRAL PLANT CLOCK TC400 GPS1000 RADIO CLOCK WITH 2M CONNECTION CABLE, ANTENNA HOLDING FRAME AND INSTALLATION MATERIAL
Industr. Time Synchronisation SICLOCK TC400 and GPS2000 Bundle with Lightning Protectio contents: - Central Plant Clock TC400 - GPS-Receiver with 2,5m Connecting Cable - Lightning Protection Module - Antenna base - Installation material
INDUSTR. TIME SYNCHRONISATION SICLOCK BUNDLE TC400 AND DCF77 RADIO CLOCK CONTAINS : CENTRAL PLANT CLOCK TC100, DCFRS RADIO CLOCK WITH 2M CONNECTING CABLE AND INSTALLATION MATERIAL.
INDUSTR. TIME SYNCHRONISATION CENTRAL PLANT CLOCK SICLOCK TC100 STAND ALONE DEVICE.
INDUSTR. TIME SYNCHRONISATION SICLOCK BUNDLE TC100 AND DCF77 RADIO CLOCK CONTAINS : CENTRAL PLANT CLOCK TC100, DCFRS RADIO CLOCK WITH 2M CONNECTION CABLE AND INSTALLATION MATERIAL.
INDUSTR. TIME SYNCHRONISATION SICLOCK BUNDLE TC100 AND GPS RADIO CLOCK CONTAINS: CENTRAL PLANT CLOCK TC100 GPS1000 RADIO CLOCK WITH 2M CONNECTION CABLE, ANTENNA HOLDING FRAME AND INSTALLATION MATERIAL
INDUST. TIME SYNCHRONISATION 19 INCH RACK FOR CENTRAL PLANT CLOCK SICLOCK TC400 / TC100.
INDUSTR. TIME SYNCHRONISATION. SICLOCK GPS RADIO CLOCK BUNDLE FOR WINDOWS CONTAINS: SICLOCK GPS1000 RADIO CLOCK, ANTENNA HOLDING FRAME AND DCF77 RECEPTION SERVICE SOFTWARE FOR WINDOWS
SOFTNET S7 LEAN FOR LINUX SYSTEMS,KERNEL 2.6.X, GLIBC 2.4 API FOR DATA EXCHANGE BETWEEN PCS AND SIMATIC S7 PLCS, MAX. 8 CONNECTIONS IT4.INDUSTRY TEL +49 9131746111
VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 1250A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: "CLOSING SPRING CHARGED" CLOSING SOLENOID 2 SHUNT RELEASES AND 1 UNDERVOLTAGE RELEASE VOLTAGE OF CLOSING SOLENOID AC 230V, VOLTAGE OF 1ST SHUNT RELEASE AC 230V, VOLTAGE OF 2ND SHUNT RELEASE AC 230V, VOLTAGE OF 3RD SHUNT
VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2000A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: "CLOSING SPRING CHARGED" CLOSING SOLENOID 1 SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 24V, VOLTAGE OF 1ST SHUNT RELEASE DC 24V, . . MANUAL OPERATING MECHANISM AUXILIARY SWITCH 6NO+6NC SECONDARY CONNECTION 64POLE PLUG
VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2000A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 2 SHUNT RELEASES UNDERVOLTAGE RELEASE VOLTAGE OF CLOSING SOLENOID AC 230V, VOLTAGE OF 1ST SHUNT RELEASE AC 230V, VOLTAGE OF 2ND SHUNT RELEASE
VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2500A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 1 SHUNT RELEASE VOLTAGE OF CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, . . VOLTAGE OF OPERATING MECHANISM DC 110V, AUXILI
VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2500A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 1 SHUNT RELEASE 1 UNDERVOLTAGE RELEASE VOLTAGE OF CLOSING SOLENOID DC 220V, VOLTAGE OF 1ST SHUNT RELEASE DC 220V, VOLTAGE OF 2ND SHUNT RELEAS
VACUUM CIRCUIT-BREAKER 36KV F.120.000 MECH.OPERATING CYCLES POLE-CENTRE DISTANCE 350MM 31.5KA 2500A OPERATG.MECHAN. EK SECONDARY EQUIPMENT: OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL 2 POSITION SWITCHES FOR SIGNAL: CLOSING SPRING CHARGED CLOSING SOLENOID WITH VARISTOR CIRCUITRY IN THE SECUNDARY CIRCUIT 1 SHUNT RELEASE 1 UNDERVOLTAGE RELEASE ELECTRICAL LOCAL CLOSING VOLTAGE OF CLOSING SOLENOID AC 230V, VOLTAGE OF 1ST SHUNT RELEASE AC 230V, VO
VACUUM CIRCUIT-BREAKER 12KV POLE-CENTRE DISTANCE 210MM 20KA 800A WITH 1ST SHUNT RELEASE WITH VARISTOR CIRCUITRY DC >= 60V WITH CLOSING SOLENOID DC 220V, VOLTAGE OF 1ST SHUNT RELEASE DC 220V, . WITH OPERATING CYCLE COUNTER BREAKER TRIPPING SIGNAL COMPLETE WIRED WITH MOTOR OPERATED STORED- ENERGY MECHANISM DC 220V WITH AUXILIARY SWITCH 6NO+6NC WITH 64-POLE PLUG MOTOR AND RELEASE ON WIRED TO LOWER PLUG PART, AUXILIARY SWITCH INTERNAL ON WIRED TO
VACUUM CIRCUIT-BREAKER 12KV POLE-CENTRE DISTANCE 210MM 31.5KA 1250A WITH 1ST SHUNT RELEASE WITH VARISTOR CIRCUITRY DC >= 60V WITH CLOSING SOLENOID DC 110V, VOLTAGE OF 1ST SHUNT RELEASE DC 110V, . WITH OPERATING CYCLE COUNTER WITH MOTOR OPERATED STORED- ENERGY MECHANISM DC 110V WITH AUXILIARY SWITCH 6NO+6NC WITH 24-POLE PLUG WITH MECHANICAL INTERLOCKING MOTOR AND TRIPPING ON WIRED TO LOWER PLUG PART, AUXILIARY SWITCH NOT WIRED RATING PLATE AND