SIEMENS

Image
Part Number
Description
Single point pressure sensor for liquids or non-corrosive gases, 0-150 PSIG, 0-10V output. System connection is 1/4" MNPT.
Single point pressure sensor for liquids or non-corrosive gases, 0-150 PSIG, 4-20mA output. System connection is 1/4" MNPT.
Single point pressure sensor for liquids or non-corrosive gases, 0-100 PSIG, 0-10V output. System connection is 1/4" MNPT.
Single point pressure sensor for liquids or non-corrosive gases, 0-100 PSIG, 4-20mA output. System connection is 1/4" MNPT.
Single point pressure sensor for liquids or non-corrosive gases, 0-60 PSIG, 0-10V output. System connection is 1/4" MNPT.
Single point pressure sensor for liquids or non-corrosive gases, 0-60 PSIG, 4-20mA output. System connection is 1/4" MNPT.
Single point pressure sensor for liquids or non-corrosive gases, 0-30 PSIG, 0-10V output. System connection is 1/4" MNPT.
Single point pressure sensor for liquids or non-corrosive gases, 0-30 PSIG, 4-20mA output. System connection is 1/4" MNPT.
Single point pressure sensor for liquids or non-corrosive gases, 0-15 PSIG, 0-10V output. System connection is 1/4" MNPT.
Single point pressure sensor for liquids or non-corrosive gases, 0-15 PSIG, 4-20mA output. System connection is 1/4" MNPT.
This 786 3-Position Commercial Selector Switch is used to deliver or stop the flow of compressed air to selected controllers, valves, or dampers. It has 10-32 female connection ports and lightweight construction and an operating temperature of 35 to 150 degrees Fahrenheit. It can be panel-mounted through one 7/32" diameter knockout.
This 786 2-Position Commercial Selector Switch is used to deliver or stop the flow of compressed air to selected controllers, valves, or dampers. It has 10-32 female connection ports, lightweight construction and an operating temperature of 35 to 150 degrees Fahrenheit. It can be panel-mounted through one 7/32" diameter knockout.
Siemens Building Technologies controls cabinets are intended for installing electronic controls and equipment inside, in addition to the existing pneumatic controls cabinets. The cabinets for electronic controls are the same as the pneumatic cabinets, with the exception of the 6” cabinet depth; the pneumatic cabinets are 9” deep. All the cabinet knock-out hole sizes and locations are the same for both pneumatic and ele
Air differential pressure sensor, 0-0.5" range, 0-10V output, 0.4% accuracy, with conduit connection.
Air differential pressure sensor, 0-0.65" range, 0-10V output, 0.4% accuracy, with conduit connection.
Air differential pressure sensor, 0-1" range, 0-10V output, 0.4% accuracy, with conduit connection.
Air differential pressure sensor, -0.25" to +0.25" range, 0-10V output, 1% accuracy,with conduit connection.
Air differential pressure sensor, 0-1" range, 0-10V output, 1% accuracy, with conduit connection.
Air differential pressure sensor, 0-2" range, 0-10V output, 1% accuracy, with conduit connection.
Air differential pressure sensor, 0-5" range, 0-10V output, 1% accuracy with conduit connection.
Air differential pressure sensor, -0.25" to +0.25" range, 0-10V output, 1% accuracy, panel mount.
Air differential pressure sensor, 0-1" range, 0-10V output, 1% accuracy, panel mount.
Air differential pressure sensor, 0-2" range, 0-10V output, 1% accuracy, panel mount.
Air differential pressure sensor, 0-5" range, 0-10V output, 1% accuracy, panel mount.
Conduit assembly kit for 590 Series Differential Pressure Sensor
SIEMENS LON RS STPT/OVRD, NO LOGO
Siemens Building Technologies controls cabinets are intended for installing electronic controls and equipment inside, in addition to the existing pneumatic controls cabinets. The cabinets for electronic controls are the same as the pneumatic cabinets, with the exception of the 6” cabinet depth; the pneumatic cabinets are 9” deep. All the cabinet knock-out hole sizes and locations are the same for both pneumatic and ele
Siemens Building Technologies controls cabinets are intended for installing electronic controls and equipment inside, in addition to the existing pneumatic controls cabinets. The cabinets for electronic controls are the same as the pneumatic cabinets, with the exception of the 6” cabinet depth; the pneumatic cabinets are 9” deep. All the cabinet knock-out hole sizes and locations are the same for both pneumatic and ele
This 567 Flush Mount Panel is for Flush Mount Control Panel Kit 567 390. The NEMA Type 1flush mount panel is designed to recess the panel into a wall and the controls are mounted within the enclosures on a perforated panel. The Kit contains escutcheon, hinged locking doors and two keys and the panel measures 19.5" tall, 16.13" wide and 5.13" deep.
This 567 Flush Mount Control Panel Kit contains escutcheon, hinged locking doors and two keys. The NEMA Type 1 kit features a removable perforated subpanel, gray finish, and knockouts for electrical or pneumatic piping.
Menu
Mail Us
enquiry@onstocktrading.com