SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,5 KW 3 AC 60HZ 460VY * 1,75 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 A11 = MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,5 KW 3 AC 60HZ 460VY * 1,75 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 B16=MOTOR FOR SWITCHING DUTY S6 60%
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,5 KW 3 AC 60HZ 460VY * 1,75 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,5 KW 3 AC 60HZ 460VY * 1,75 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,5 KW 3 AC 60HZ 460VY * 1,75 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,5 KW 3 AC 60HZ 460VY * 1,75 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009) K35= EXTERNAL METAL FAN K45=SPACE HEATER, 230V
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,5 KW 3 AC 60HZ 460VY * 1,75 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200) G26=SPRING PRESSURE BRAKE 1 AC 50HZ 230V INCLUDING MOUNTING COSTS H57=PULSE GENERATOR 1XP8 001-1 1024 PULSES PER REV. INCLUDING MOUNTING COSTS W.UNIT
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,5 KW 3 AC 60HZ 460VY * 1,75 KW IMB14, IMV19 IMV18 WITHOUT CANOPY STANDARD FLANGE: FT115 (C140)
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,5 KW 3 AC 60HZ 460VY * 1,75 KW IMB14, IMV19 IMV18 WITHOUT CANOPY STANDARD FLANGE: FT115 (C140) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009) D47=TR CU PRODUCT SAFETY CERTIFICATE EAC FOR THE EURASIAN CUSTOMS UNION
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,5 KW 3 AC 60HZ 460VY * 1,75 KW IMB34, SPECIAL FLANGE: C 160 C24=THERM.CL.155(F), ACC. TO 130(B), COOLING TEMP. 55 DEG. C POWER REDUCTION BY 13% D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 400VD/690VY * 1,5 KW 3 AC 60HZ 460VD * 1,75 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 380VD/660VY * 1,5 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200) C01=BRAKE SUPPLY VOLTAGE AC 400V D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009) G26=SPRING PRESSURE BRAKE 1 AC 50HZ 230V INCLUDING MOUNTING COSTS K82=MANUAL RELEASE OF BRAKE USING A LEVER
SIMOTICS GP ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 380VD/660VY * 1,5 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 90 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 415VD * 1,5 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 6-POLE * SIZE 90 L THERM. CL.155(F) IE1* ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 1,1 KW 3 AC 60HZ 460VY * 1,3 KW 220-240/380-420(50);440-480(60) IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF165 (A 200) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 8-POLE * SIZE 90 L THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,55 KW 3 AC 60HZ 460VY * 0,63 KW 220-240/380-420(50);440-480(60) IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6
SIMOTICS GP ONLY EX AND PM VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 100 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 3 KW 3 AC 60HZ 460VY * 3,45 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6
SIMOTICS GP ONLY EX AND PM VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 100 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 400VD/690VY * 3 KW 3 AC 60HZ 460VD * 3,45 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6
SIMOTICS GP ONLY EX AND PM VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 100 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 2,2 KW 3 AC 60HZ 460VY * 2,55 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF215 (A 250)
SIMOTICS GP ONLY EX AND PM VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 100 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 400VD/690VY * 2,2 KW 3 AC 60HZ 460VD * 2,55 KW IMB35 * FLANGE: FF215 (A 250)
SIMOTICS GP ONLY EX AND PM VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 100 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 3 KW 3 AC 60HZ 460VY * 3,45 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6
SIMOTICS GP ONLY EX AND PM VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 100 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 3 KW 3 AC 60HZ 460VY * 3,45 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF215 (A 250)
SIMOTICS GP ONLY EX AND PM VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 100 L THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3AC 50HZ 400VY * 3 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 A11 = MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN K31 = ADDITIONAL RATING PLATE, UNASSEMBLED M39=VERSION FOR ZONE 22 WITH NON-CONDUCTING DUST (IP55) CONVERTER-FED OPERATION - REDUCED POWER EX TC IIIB T125 DEGREES DC
SIMOTICS GP Only EX and PM version! Low-voltage motor, squirrel-cage rotor, IP55 8-pole* Size 100L, * temperature class 155(F), aluminum housing 3 AC 50 Hz 230 VD/400 VY * 1.1 kW 3 AC 60 Hz 460 VY * 1.3 kW 220-240/380-420 (50); 440-480 (60) IM B3, IM B6, IM B 7, IM B 8, IM V 5 without canopy, IM V 6
SIMOTICS GP ONLY EX AND PM VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 112 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 4 KW 3 AC 60HZ 460VY * 4,6 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6
SIMOTICS GP ONLY EX AND PM VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 112 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 4 KW 3 AC 60HZ 460VY * 4,6 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 A11 = MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN
SIMOTICS GP ONLY EX AND PM VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 112 M THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 4 KW 3 AC 60HZ 460VY * 4,6 KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF215 (A 250)
SIMOTICS GP ONLY EX AND PM VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 132 S THERM. CL.155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 400VD/690VY * 5,5 KW 3 AC 60HZ 460VD * 6,3 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 A11 = MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN