SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE, SIZE 225 M THERMAL CLASS 155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 400VD/690VY * 45 KW 3 AC 60HZ 460VD * 52 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 6-POLE, SIZE 225 M THERMAL CLASS 155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 400VD/690VY * 30 KW 3 AC 60HZ 460VD * 36 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 C01=BRAKE SUPPLY VOLTAGE AC 400V D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009) D47=TR CU PRODUCT SAFETY CERTIFICATE EAC FOR THE EURASIAN CUSTOMS UNION G26=SPRING PRESSURE BRAKE 1 AC 50HZ 230V
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 6-POLE, SIZE 225 M THERMAL CLASS 155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 400VD/690VY * 30 KW 3 AC 60HZ 460VD * 36 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 C01=BRAKE SUPPLY VOLTAGE AC 400V D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009) G26=SPRING PRESSURE BRAKE 1 AC 50HZ 230V INCLUDING MOUNTING COSTS
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 6-POLE, SIZE 225 M THERMAL CLASS 155(F) IE1 * ALUMINUM ENCL. 3 AC 50HZ 400VD/690VY * 30 KW 3 AC 60HZ 460VD * 36 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 G26=SPRING PRESSURE BRAKE 1 AC 50HZ 230V INCLUDING MOUNTING COSTS C01=BRAKE SUPPLY VOLTAGE AC 400V
SIMOTICS SD LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 100L * THERMAL CLASS 155(F) IE1 * GREY CAST-IRON ENCL. 3 AC 50HZ 380VD/660VY * 3 KW IMB35 * FLANGE: FF215 (A 250) A11 = MOTOR PROTECTION WITH 3 PTC THERMISTORS FOR SHUTDOWN D22=IE1 MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS SD ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 132S * THERMAL CLASS 155(F) IE1 * GREY CAST-IRON ENCL. NON-STANDARD WINDING 3 AC ..HZ, ...V, ...KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 M73=VERSION FOR ZONE 2 CONVERTER-FED OPERATION - REDUCED POWER EX NA IIC T3 GC EX TC IIIB T125 GRAD DC
SIMOTICS SD ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 160M * THERMAL CLASS 155(F) IE1 * GREY CAST-IRON ENCL. 3 AC 50HZ 500VD * 11 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 C13=ACC.TO THERM. CL. 155 (F) WITH HIGHER COOLANT TEMPERATURE (55 CEL) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS SD LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 6-POLE * SIZE 160M * THERMAL CLASS 155(F) IE1 * CAST-IRON ENCL. 3 AC 50HZ 230VD/400VY * 7,5 KW 3 AC 60HZ 460VY * 8,6 KW 220-240/380-420(50);440-480(60) IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF300 (A 350) D22=IE1 MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009)
SIMOTICS SD ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 160M * THERMAL CLASS 155(F) IE1 * GREY CAST-IRON ENCL. 3 AC 50HZ 400VD * 15 KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 A10=PTC VERSION FOR WARNING DURING CONVERTER OPERATION IN ZONES 2, 21 AND 22 M39=VERSION FOR ZONE 22 WITH NON-CONDUCTING DUST (IP55) CONVERTER-FED OPERATION - REDUCED POWER EX TC IIIB T125 DEGREES DC
SIMOTICS SD ONLY EX VERSIONS! LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 8-POLE * SIZE 160L * THERMAL CLASS 155(F) GREY CAST-IRON ENCL. 3 AC 50HZ 230VD/400VY * 7,5 KW 3 AC 60HZ 460VY * 8,6 KW 220-240/380-420(50);440-480(60) IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 A12 = MOTOR PROTECTION WITH 6 PTC THERMISTORS FOR ALARM AND SHUTDOWN D04= COOLANT TEMPERATURE -30 CEL TO +40 CEL
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 63 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,18 KW 3 AC 60HZ 460VY * 0,21 KW 220-240/380-420(50);440-480(60) IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF115 (A 140)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 63 M THERM. CL.155(F) ALUMINUM ENCL. NON-STANDARD WINDING 3 AC ..HZ, ...V, ...KW IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 Y58=NON-STANDARD CYLINDRICAL SHAFT EXTENSION DE,
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 63 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,12 KW 3 AC 60HZ 460VY * 0,14 KW 220-240/380-420(50);440-480(60) IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6 D01=CCC CHINA COMPULSORY CERT.
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 63 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,12 KW 3 AC 60HZ 460VY * 0,14 KW 220-240/380-420(50);440-480(60) IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF115 (A 140)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 63 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,25 KW 3 AC 60HZ 460VY * 0,29 KW 220-240/380-420(50);440-480(60) IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF115 (A 140)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 63 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,18 KW 3 AC 60HZ 460VY * 0,21 KW 220-240/380-420(50);440-480(60) IM B 3, IM B 6, IM B 7, IM B 8, IM V 5 W/O CANOPY, IM V 6
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 63 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,18 KW 3 AC 60HZ 460VY * 0,21 KW 220-240/380-420(50);440-480(60) IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF115 (A 140)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 63 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,18 KW 3 AC 60HZ 460VY * 0,21 KW 220-240/380-420(50);440-480(60) IMB14, IMV19 IMV18 WITHOUT CANOPY STANDARD FLANGE: FT75 (C90) D22=MOTOR WITHOUT CE MARK FOR EXPORT OUTSIDE OF EEA (SEE EU REGULATION 640/2009) D47=TR CU PRODUCT SAFETY CERTIFICATE EAC FOR THE EURASIAN CUSTOMS UNION
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 4-POLE * SIZE 63 M THERM. CL.155(F) ALUMINUM ENCL. NON-STANDARD WINDING 3 AC ..HZ, ...V, ...KW IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF115 (A 140) D31=TO UL WITH RECOGNITION MARK D40=TO CANADIAN STANDARDS (CSA)
SIMOTICS GP LOW-VOLTG. SQUIRREL-CAGE MOTOR IP55, 2-POLE * SIZE 71 M THERM. CL.155(F) ALUMINUM ENCL. 3 AC 50HZ 230VD/400VY * 0,37 KW 3 AC 60HZ 460VY * 0,43 KW 220-240/380-420(50);440-480(60) IM B5, IM V1 W/O CANOPY, IM V3 FLANGE: FF130 (A 160)