SIEMENS

Image
Part Number
Description
PCS 7 BLOCK LIBRARY, SIMOCODE PRO V6.0; AS BLOCKS AND FACEPLATES FOR INTEGRATION OF SIMOCODE PRO IN PCS 7 PROCESS CONTROL SYSTEM FOR THE PCS 7 VERSION V6.0; ENGINEERING SOFTWARE FOR AN ENGINEERING STATION (SINGLE LICENSE) INCL. RUNTIME SOFTWARE FOR EXECUTING THE AS BLOCK IN AN AUTOMATION SYSTEM (SINGLE LICENSE); GERMAN/ ENGLISH/FRENCH; SUPPLIED ON CD
PCS 7 BLOCK LIBRARY SIMOCODE PRO V6.X; AS BLOCKS FOR INTEGRATION OF SIMOCODE PRO IN PCS 7 PROCESS CONTROL SYSTEM FOR THE PCS 7 VERSION V6.X; RUNTIME SOFTWARE FOR EXECUTING THE AS BLOCK IN AN AUTOMATION SYSTEM (SINGLE LICENSE); LICENSE WITHOUT SOFTWARE AND DOCUMENTATION
PCS 7 BLOCK LIBRARY, SIMOCODE PRO V7.0; AS BLOCKS AND FACEPLATES FOR INTEGRATION OF SIMOCODE PRO IN PCS 7 PROCESS CONTROL SYST. FOR THE PCS 7 VERSION V7.0; ENGINEERING SOFTWARE FOR AN ENGINEERING STATION (SINGLE LICENSE) INCL. RUNTIME SOFTWARE FOR EXECUTING THE AS BLOCK IN AN AUTOMATION SYSTEM (SINGLE LICENSE); GERMAN/ENGLISH/FRENCH; SUPPLIED ON CD
PCS 7 BLOCK LIBRARY, SIMOCODE PRO V7.X; AS BLOCKS FOR INTEGRATION OF SIMOCODE PRO IN PCS 7 PROCESS CONTROL SYSTEM FOR THE PCS 7 VERSION V7.X; RUNTIME FOR EXECUTING THE AS BLOCK IN AN AUTOMATION SYSTEM (SINGLE LICENSE); LICENSE WITHOUT SOFTWARE AND DOCUMENTATION
UPGRADE, FOR THE PCS 7 BLOCK LIBRARY, SIMOCODE PRO V6.0 OR V6.1 TO THE VERSION SIMOCODE PRO V7.0, FOR INTEGRATION OF SIMOCODE PRO IN PCS 7 PROCESS CONTROL SYST.; FOR THE PCS 7 VERSION V7.0; (SINGLE LICENSE); GERMAN/ ENGLISH/FRENCH; SUPPLIED ON CD
PCS 7 BLOCK LIBRARY, SIMOCODE PRO MIGRATION V7-V8; AS BLOCKS AND FACEPLATES FOR INTEGRATION OF SIMOCODE PRO IN PCS 7 PROCESS CONTROL SYST. FOR PCS 7 VERSION V8.0; ENGINEERING SOFTWARE FOR ONE ENGINEERING STATION (SINGLE LICENSE) INCL. RUNTIME SOFTWARE FOR EXECUTING THE AS BLOCK IN AN AUTOMATION SYSTEM (SINGLE LICENSE); GERMAN/ENGLISH/FRENCH; TYPE OF DELIVERY: CD TERMS OF USE: LICENSE FOR ENGINEERING SW V7 SIMOCODE PRO SIMOCDODE PRO
SINGLE-POLE BOW-TYPE ELECTRODE FOR LATERAL INSTALLATION FOR LEVEL MONITORING
SINGLE-POLE ELECTRODE FOR LATERAL INSTALLATION FOR LEVEL MONITORING, MECHAN. STABLE VERSION
DOUBLE-POLE WIRE ELECTRODE FOR LEVEL MONITORING, 500 MM LONG, WITH TEFLON INSULATION
DOUBLE-POLE BOW-TYPE ELECTRODE FOR LEVEL MONITORING
TRIPLE-POLE WIRE ELECTRODE FOR LEVEL MONITORING, 500 MM LONG, WITH TEFLON INSULATION
ANALOG MONITORING RELAY FILL LEVEL MONITORING RESISTANCE MONITORING FROM 2 TO 200 KOHM OVERSHOOT AND UNDERSHOOT SUPPLY VOLTAGE: 24 V AC/DC DC AND AC 50 TO 60 HZ NO GALVANIC ISOLATION FROM MEASURING CIRCUIT 2-POINT OR 1-POINT CONTROL TRIPPING DELAY 0.5 TO 10S 1 CO CONTACT SCREW TERMINAL REPLACEMENT PRODUCT FOR 3UG3501-1AC20
ANALOG MONITORING RELAY FILL LEVEL MONITORING RESISTANCE MONITORING FROM 2 TO 200 KOHM OVERSHOOT AND UNDERSHOOT AC/DC 24 TO 240V DC AND AC 50 TO 60 HZ 2-POINT OR 1-POINT CONTROL TRIPPING DELAYED 0.5 TO 10S 1 CHANGEOVER CONTACT SCREW TERMINAL REPLACEMENT PRODUCT F. 3UG3501
DC AND AC 50 TO 60 HZ 2-POINT OR 1-POINT CONTROL TRIPPING DELAYED 0.5 TO 10S 1 CHANGEOVER CONTACT SPRING-LOADED TYPE
ANALOG MONITORING RELAY FILL LEVEL MONITORING RESISTANCE MONITORING FROM 2 TO 200 KOHM OVERSHOOT AND UNDERSHOOT AC/DC 24 TO 240V DC AND AC 50 TO 60 HZ 2-POINT OR 1-POINT CONTROL TRIPPING DELAYED 0.5 TO 10S 1 CHANGEOVER CONTACT SPRING-LOADED TYPE
ANALOG MONITORING RELAY PHASE SEQUENCE MONITORING 3X 160 TO 260V AC 50 TO 60 HZ 1 CHANGEOVER CONTACT SCREW TERMINAL REPLACEMENT PRODUCT FOR 3UG3511-1AQ50 OR 3UG3511-1AV50
ANALOG MONITORING RELAY PHASE SEQUENCE MONITORING 3X 360 TO 520V AC 50 TO 60 HZ 1 CHANGEOVER CONTACT SCREW TERMINAL REPLACEMENT PRODUCT FOR 3UG3511-1AQ50
ANALOG MONITORING RELAY PHASE SEQUENCE MONITORING 3X 420 TO 690V AC 50 TO 60 HZ 1 CHANGEOVER CONTACT SCREW TERMINAL
ANALOG MONITORING RELAY PHASE SEQUENCE MONITORING 3X 160 TO 260V AC 50 TO 60 HZ 2 CHANGEOVER CONTACTS SCREW TERMINAL REPLACEMENT PRODUCT FOR 3UG3511-1BQ50
ANALOG MONITORING RELAY PHASE SEQUENCE MONITORING 3X 360 TO 520V AC 50 TO 60 HZ 2 CHANGEOVER CONTACTS SCREW TERMINAL REPLACEMENT PRODUCT FOR 3UG3511-1BQ50
ANALOG MONITORING RELAY PHASE SEQUENCE MONITORING 3X 420 TO 690V AC 50 TO 60 HZ 2 CHANGEOVER CONTACTS SCREW TERMINAL
ANALOG MONITORING RELAY PHASE SEQUENCE MONITORING 3X 160 TO 260V AC 50 TO 60 HZ 1 CHANGEOVER CONTACT SPRING LOADED CONNECTION
ANALOG MONITORING RELAY PHASE SEQUENCE MONITORING 3X 360 TO 520V AC 50 TO 60 HZ 1 CHANGEOVER CONTACT SPRING LOADED CONNECTION
ANALOG MONITORING RELAY PHASE SEQUENCE MONITORING 3X 420 TO 690V AC 50 TO 60 HZ 1 CHANGEOVER CONTACT SPRING LOADED CONNECTION
ANALOG MONITORING RELAY PHASE SEQUENCE MONITORING 3X 160 TO 260V AC 50 TO 60 HZ 2 CHANGEOVER CONTACTS SPRING LOADED CONNECTION
ANALOG MONITORING RELAY PHASE SEQUENCE MONITORING 3X 360 TO 520V AC 50 TO 60 HZ 2 CHANGEOVER CONTACTS SPRING LOADED CONNECTION
ANALOG MONITORING RELAY PHASE SEQUENCE MONITORING 3X 420 TO 690V AC 50 TO 60 HZ 2 CHANGEOVER CONTACTS SPRING LOADED CONNECTION
ANALOG MONITORING RELAY PHASE FAILURE AND -SEQUENCE 3X 160 TO 690V AC 50 TO 60 HZ 2 CHANGEOVER CONTACTS SCREW TERMINAL REPLACEMENT PRODUCT FOR 3UG3513-1BL50 OR 3UG3513-1PB50
ANALOG MONITORING RELAY PHASE FAILURE AND -SEQUENCE 3X 160 TO 690V AC 50 TO 60 HZ 1 CHANGEOVER CONTACT SPRING LOADED CONNECTION
ANALOG MONITORING RELAY PHASE FAILURE AND -SEQUENCE 3X 160 TO 690V AC 50 TO 60 HZ 2 CHANGEOVER CONTACTS SPRING LOADED CONNECTION
Menu
Mail Us
enquiry@onstocktrading.com