SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1570N;FN = 1190N; VMAX_FN = 57,5M/MIN; VMAX_FMAX = 32,4M/MIN; IN = 4,6A;IMAX = 7,45A; P_N =2,31KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1570N;FN = 1190N; VMAX_FN = 167M/MIN; VMAX_FMAX = 110M/MIN; IN = 11,2A;IMAX = 18,2A; P_N =4,58KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1890N;FN = 1430N; VMAX_FN = 135M/MIN; VMAX_FMAX = 87,9M/MIN; IN = 11,2A;IMAX = 18,2A; P_N =4,74KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; WATER COOLING SYSTEM; 3-PHASE SYNCHRONOUS MOTOR; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1890N;FN = 1430N; VMAX_FN = 288M/MIN; VMAX_FMAX = 194M/MIN; IN = 21A;IMAX = 36,3A; P_N =8,42KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 898N;FN,TH = 234 ...572N FN = 303N; VMAX_FN = 236M/MIN; VMAX_FMAX = 98,5M/MIN; IN,TH = 1,67...4,32A;IN = 2,17A IMAX =8,64A;P_N = 1,52KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGT
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 898N; FN,TH = 309...572N;FN = 374N; VMAX_FN = 473M/MIN; VMAX_FMAX = 224M/MIN; IN,TH = 4,62...9A;IN = 5,65A; IMAX =18A;P_N = 3,1KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1800N; FN,TH = 617...1140N; FN = 749N; VMAX_FN = 221M/MIN; VMAX_FMAX = 96,8M/MIN; IN,TH = 4,62...9A;IN = 5,65A; IMAX =18A;P_N = 3,06KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1800N; FN,TH = 617...1140N;FN = 749N; VMAX_FN = 456M/MIN; VMAX_FMAX = 207M/MIN; IN,TH = 9,24...18A;IN = 11,3A; IMAX =36A;P_N = 5,99KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 2690N;FN,TH = 926...1720 FN = 1120N; VMAX_FN = 224M/MIN; VMAX_FMAX = 96,7M/MIN; IN,TH = 7,11...13,8A; IN = 8,69A;IMAX =27,7A; P_N = 4,64KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RI
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6;3-PHASE SYNCHRONOUS MOTOR;SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 2690N;FN,TH = 926...1720 FN = 1120N;VMAX_FN = 449M/MIN; VMAX_FMAX = 200M/MIN; IN,TH = 13,9...27A;IN = 17A; IMAX =54A;P_N = 8,87KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VI
SIMOTICS L SECONDARY SECTION FOR LINEAR MOTOR 1FN6; OMPONENT 3-PHASE SYNCHRONOUS MOTOR; FRAME SIZE 1FN6008 LENGTH 200MM; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1800N; FN,TH = 543 ...1140N;FN = 692N; VMAX_FN = 241M/MIN; VMAX_FMAX = 110M/MIN; IN,TH = 4,05...9A; IN = 5,2A;IMAX =18A; P_N = 2,98KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6;3-PHASE SYNCHRONOUS MOTOR;SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1800N;FN,TH = 543...1140 FN = 692N; VMAX_FN = 377M/MIN; VMAX_FMAX = 176M/MIN; IN,TH = 6,23...13,8A; IN = 8A;IMAX =27,7A; P_N = 4,55KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS AR
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6;3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 3590N; FN,TH = 1090...2290N;FN = 1380N VMAX_FN = 233M/MIN; VMAX_FMAX = 101M/MIN; IN,TH = 8,11...18A; IN = 10,4A;IMAX =36A; P_N = 5,8KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR;SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 3590N; FN,TH = 1090...2290N; FN = 1380N;VMAX_FN = 365M/MIN; VMAX_FMAX = 162M/MIN; IN,TH = 12,5...27,7A; IN = 16A;IMAX =55,4A; P_N = 8,83KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIG
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6;3-PHASE SYNCHRONOUS MOTOR;SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 5390N; FN,TH = 1630 ...3430N; FN = 2070N;VMAX_FN = 230M/MIN; VMAX_FMAX = 98,2M/MIN; IN,TH = 12,2...27A; IN = 15,6A;IMAX =54,1A; P_N = 8,59KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RI
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6;3-PHASE SYNCHRONOUS MOTOR;SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 5390N; FN = 2070N; FN,TH = 1410 ...3430N; VMAX_FN = 360M/MIN; VMAX_FMAX = 156M/MIN; IN,TH = 18,7...41,5A; IN = 24A;IMAX =83,1A; P_N = 13,1KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RI
SIMOTICS L SECONDARY SECTION FOR LINEAR MOTOR 1FN6; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FRAME SIZE 1FN6016 LENGTH 200MM; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 2690N; FN,TH = 758...1720N; FN = 1000N;VMAX_FN = 160M/MIN; VMAX_FMAX = 70,1M/MIN; IN,TH = 3,76...9A; IN = 5A;IMAX =18A; P_N = 2,93KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS A
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6;3-PHASE SYNCHRONOUS MOTOR;SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 2690N; FN,TH = 758 ...1720N; FN = 1000N; VMAX_FN = 252M/MIN; VMAX_FMAX = 115M/MIN; IN,TH = 5,79...13,8A;IN = 7,69A IMAX =27,7A;P_N = 4,46KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIG
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6;3-PHASE SYNCHRONOUS MOTOR;SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 5390N; FN = 2000N; FN,TH = 1520 ...3430N; VMAX_FN = 155M/MIN; VMAX_FMAX = 64,8M/MIN; IN,TH = 7,53...18A; IN = 10A;IMAX =36A; P_N = 5,71KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTH
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 5390N; FN,TH = 1520 ...3430N; FN = 2000N;VMAX_FN = 244M/MIN; VMAX_FMAX = 106M/MIN; IN,TH = 11,6...27,7A; IN = 15,4A;IMAX =55,4A; P_N = 8,68KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6;3-PHASE SYNCHRONOUS MOTOR;SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 8080N; FN,TH = 2270 ...5140N; FN = 3000N;VMAX_FN = 153M/MIN; VMAX_FMAX = 62,8M/MIN; IN,TH = 11,3...27A; IN = 15A;IMAX =54,1A; P_N = 8,47KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGT
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 8080N; FN,TH = 2270 ...5140N; FN = 3000N;VMAX_FN = 241M/MIN; VMAX_FMAX = 102M/MIN; IN,TH = 17,4...41,5A; IN = 23,1A;IMAX =83,1A; P_N = 12,9KW; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT
SIMOTICS L SECONDARY SECTION FOR LINEAR MOTOR 1FN6; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FRAME SIZE 1FN6024 LENGTH 200MM; SLIDNG BLOCKS INCLUDED IN THE SCOPE OF SUPPLY