SIEMENS - SIMOTICS L

Image
Part Number
Description
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 900; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 900; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3,5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 800; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 4 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 900; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 900; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 5,5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 900; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 6,5 SECONDARY SECTION SEGMENTS
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=8100N; FMAX=20700N; VMAX_FN=160M/MIN; VMAX=65M/MIN; IN=49,4A; IMAX=138,9A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=8100N; FMAX=20700N; VMAX_FN=160M/MIN; VMAX_FMAX=65M/MIN; IN=49,4A; IMAX=138,9A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=8100N; FMAX=20700N; VMAX_FN=203M/MIN; VMAX_FMAX=88M/MIN; IN=60,6A; IMAX=170,3A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=8100N; FMAX=20700N; VMAX_FN=203M/MIN; VMAX_FMAX=88M/MIN; IN=49,4A; IMAX=138,9A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=8100N; FMAX=20700N; VMAX_FN=253M/MIN; VMAX=115M/MIN; IN=73,5A; IMAX=206,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=8100N; FMAX=20700N; VMAX_FN=253M/MIN; VMAX_FMAX=115M/MIN; IN=73,5A; IMAX=206,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 157N; FN,TH = 49...119N; FN = 66,3N; VMAX_FN = 748M/MIN; VMAX_FMAX = 345M/MIN; IN,TH = 1,17...3,2A; IN = 1,61A;IMAX =5,18A; P_N = 0,864KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIO
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 157N; FN,TH = 49...119N; FN = 66,3N; VMAX_FN = 1080M/MIN; VMAX_FMAX = 503M/MIN; IN,TH = 1,69...4,6A; IN = 2,31A;IMAX =7,45A; P_N = 1,24KW;
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 315N; FN,TH = 98...239N; FN = 133N; VMAX_FN = 515M/MIN; VMAX_FMAX = 226M/MIN; IN,TH = 1,69...4,6A; IN = 2,31A;IMAX =7,45A; P_N = 1,21KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLA
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 315N; FN,TH = 98...239N; FN = 133N; VMAX_FN = 1280M/MIN; VMAX_FMAX = 572M/MIN; IN,TH = 4,11...11,2A; IN = 5,62A;IMAX =18,2A; P_N = 2,91KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIO
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 472N; FN,TH = 147...358N; FN = 199N; VMAX_FN = 333M/MIN; VMAX_FMAX = 141M/MIN; IN,TH = 1,69...4,6A; IN = 2,31A;IMAX =7,45A; P_N = 1,22KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOL
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 472N; FN,TH = 147...358N; FN = 199N; VMAX_FN = 836M/MIN; VMAX_FMAX = 366M/MIN; IN,TH = 4,11...11,2A; IN = 5,63A;IMAX =18,2A; P_N = 2,9KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOL
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 630N; FN,TH = 196...477N;FN = 265N; VMAX_FN = 243M/MIN; VMAX_FMAX = 99,6M/MIN; IN,TH = 1,69...4,6A;IN = 2,31A; IMAX =7,45A; P_N = 1,23KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOL
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 630N; FN,TH = 196...477N; FN = 265N; VMAX_FN = 618M/MIN; VMAX_FMAX = 267M/MIN; IN,TH = 4,11...11,2A;IN = 5,63A IMAX =18,2A;P_N = 2,89KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLA
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 787N;FN,TH = 245...597N; FN = 332N; VMAX_FN = 190M/MIN; VMAX_FMAX = 74,7M/MIN; IN,TH = 1,69...4,6A;IN = 2,31A; IMAX =7,45A; P_N = 1,24KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOL
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 787N;FN,TH = 245...597N; FN = 332N; VMAX_FN = 488M/MIN; VMAX_FMAX = 208M/MIN; IN,TH = 4,11...11,2A; IN = 5,63A;IMAX =18,2A; P_N = 2,9KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLA
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 945N;FN,TH = 294 ...716N FN = 397N;VMAX_FN = 155M/MIN; VMAX_FMAX = 57,9M/MIN; IN,TH = 1,69...4,6A;IN = 2,31A; IMAX =7,45A; P_N = 1,25KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLA
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 945N; FN,TH = 294 ...716N; FN = 398N;VMAX_FN = 402M/MIN; VMAX_FMAX = 169M/MIN; IN,TH = 4,11...11,2A;IN = 5,63A IMAX =18,2A;P_N = 2,91KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLA
SIMOTICS L SECONDARY SECTION FOR LINEAR MOTOR 1FN6; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COMPENSATING PIECE OF LENGTH; FRAME SIZE 1FN6003; LENGTH 200MM
SIMOTICS L SECONDARY SECTION FOR LINEAR MOTOR 1FN6; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FRAME SIZE 1FN6003; LENGTH 500MM;
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 157N;FN = 119N; VMAX_FN = 509M/MIN; VMAX_FMAX = 345M/MIN; IN = 3,2A;IMAX = 5,18A; P_N =1,16KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 157N;FN = 119N; VMAX_FN = 740M/MIN; VMAX_FMAX = 503M/MIN; IN = 4,6A;IMAX = 7,45A; P_N =1,62KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 315N;FN = 239N; VMAX_FN = 339M/MIN; VMAX_FMAX = 226M/MIN; IN = 4,6A;IMAX = 7,45A; P_N =1,65KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; PERMANENTLY CONNECTED POWER AND SIGNAL CABLES PREASSEMBLED WITH PLUGS; LENGTH 0,5M; FMAX = 315N;FN = 239N; VMAX_FN = 852M/MIN; VMAX_FMAX = 572M/MIN; IN = 11,2A;IMAX = 18,2A; P_N =3,71KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
Menu
Mail Us
enquiry@onstocktrading.com