SIEMENS - SIMOTICS L

Image
Part Number
Description
SECONDARY SECTION FOR LINEAR MOTOR; COMPONENT 3-PHASEN SYNCHRONOUS MOTOR; OVERALL LENGTH 226 MM FRAME SIZE 1FN1070-0AA00-0AA0 ROBUST DESIGNED
SECONDARY SECTION FOR LINEAR MOTOR; COMPONENT 3-PHASEN SYNCHRONOUS MOTOR; OVERALL LENGTH 564 MM FRAME SIZE 1FN1070-0AA00-1AA0 ROBUST DESIGNED
PRIMARY SECTION FOR LINEAR MOTOR; COMPONENT 3-PHASEN- SYNCHRONOUS MOTOR; 600 V DC LINK, 1580 N, 200 M/MIN, WATER-COOLED, IP 65 POWER CONNECTOR LOW-PRESSURE HYDRAULIC CONNECT.
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR; COMPONENT 3-PHASEN- SYNCHRONOUS MOTOR; 600 V DC LINK,1580 N, 200 M/MIN WATER-COOLED, IP 65, CABLE OUTLET, ALUMINIUM COOLING-WATER CONNECTION
SECONDARY SECTION FOR LINEAR MOTOR; COMPONENT 3-PHASEN SYNCHRONOUS MOTOR; OVERALL LENGTH 216 MM FRAME SIZE 1FN1120-0AA00-0AA0 ROBUST DESIGNED
SECONDARY SECTION FOR LINEAR MOTOR; COMPONENT 3-PHASEN SYNCHRONOUS MOTOR; OVERALL LENGTH 504 MM FRAME SIZE 1FN1120-0AA00-1AA0 ROBUST DESIGNED
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR; COMPONENT 3-PHASEN- SYNCHRONOUS MOTOR; 600 V DC LINK,2200 N, 145 M/MIN WATER-COOLED, IP 65, POWER CONNECTOR, ALUMINIUM COOLING-WATER CONNECTION
SECONDARY SECTION FOR LINEAR MOTOR; COMPONENT 3-PHASEN SYNCHRONOUS MOTOR; OVERALL LENGTH 216 MM
SECONDARY SECTION FOR LINEAR MOTOR; COMPONENT 3-PHASEN SYNCHRONOUS MOTOR; OVERALL LENGTH 504 MM
PRIMARY SECTION FOR LINEAR MOTOR; COMPONENT 3-PHASEN- SYNCHRONOUS MOTOR; 600 V DC LINK,3600 N, 145 M/MIN WATER-COOLED, IP 65 POWER CONNECTOR LOW-PRESSURE HYDRAULIC CONNECTION
SIMOTICS L LINEAR MOTOR CONNECTOR BOX FOR CONNECTION OF INCREMENTAL MEASURING SYSTEM, IP 65
SIMOTICS L LINEAR MOTOR CONNECTOR BOX FOR CONECTION OF ABSOLUTE MEASURING SYSTEM, IP 65
SIMOTICS L SME91 SENSOR MODUL EXTERNAL FOR ONE 1FN- OR 1FW6-MOTOR; FOR CONNECTION OFEMPERATURE SENSORS AND ONE ABSOLUTE POSITION MEASURING SYSTEM
SIMOTICS L SME92 SENSOR MODUL EXTERNAL FOR TWO 1FN- OR 1FW6-MOTOR; FOR CONNECTION OF TEMPERATURE SENSORS AND ONE ABSOLUTE POSITION MEASURING SYSTEM
SIMOTICS L SME93 SENSOR MODUL EXTERNAL FOR ONE 1FN- OR 1FW6-MOTOR; FOR CONNECTION OF TEMPERAURE SENSORS AND ONE INCREMENTAL POSITION MEASURING SYSTEM; OPTIONAL CONNECTION OF A HALL-EFFECT SENSOR BOX IS POSSIBLE
SIMOTICS L SME94 SENSOR MODUL EXTERNAL FOR TWO 1FN- OR 1FW6-MOTOR; FOR CONNECTION OF TEMPERAURE SENSORS AND ONE INCREMENTAL POSITION MEASURING SYSTEM; OPTIONAL CONNECTION OF A HALL-EFFECT SENSOR BOX IS POSSIBLE
SIMOTICS L LID FOR TERMINAL BOX; WITH TAPPED THROUGH HOLE PG16; FOR FRAME SIZE 100 TO 150 COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
SIMOTICS L LID FOR TERMINAL BOX; WITH TAPPED THROUGH HOLE M20 FOR POWER AND TAPPED THROUGH HOLE M20 FOR SIGNAL, FOR FRAME SIZE 100 TO 150 COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
SIMOTICS L HALL-EFFECT SENSOR BOX FOR POLARITY DETERMINATION(COMMUTING); STRAIGHT CABLE EXIT, FOR FRAME SIZE 50 TO 150; PRIMARY SECTION LENGTH: 2, 4 (STAND.) 2,3,4,5 (VARIANT)
SIMOTICS L HALL SENSOR BOX FOR POLARITY DETERMINATION (COMMUTING); FOR SERIES 050 TO 200, 14 M CABLE
SIMOTICS L HALL-EFFECT SENSOR BOX FOR POLARITY DETERMINATION(COMMUTING); LATERAL CABLE EXIT, FOR FRAME SIZE 050 TO 150 PRIMARY SECTION LENGTH: 2, 4 (STAND.) 2,3,4,5 (VARIANT)
SIMOTICS L SECONDARY SECTION COOLING; FRAME SIZE 050 TO 150; HOLLOW PROFILE - ALUMINIUM; 2 PER EACH SECOND UNIT TRACK; LENGTH 490 MM
SIMOTICS L COOLING SYSTEM FOR SECONDARY UNIT CONSTR. SERIES 050 TO 200 HOLLOW PROFILE - ALUMINIUM; 2 PER EACH SECOND. UNIT TRACK, LENGTH ACC. TO NUMBER OF SECONDARY UNITS, WITH CABLE SLEEVE NIPPLE FOR (COMBINATED) END PIECE PRICE PER SECONDARY UNIT SEGM. NUMBER = 0 + 1
SIMOTICS L COOLING SYSTEM FOR SECONDARY UNIT CONSTR. SERIES 050 TO 200 HOLLOW PROFILE - ALUMINIUM; 2 PER EACH SECOND. UNIT TRACK, LENGTH ACC. TO NUMBER OF SECONDARY UNITS, WITH CABLE SLEEVE NIPPLE FOR (COMBINATED) END PIECE PRICE PER SECONDARY UNIT SEGM. NUMBER = 0 + 2
SIMOTICS L COOLING SYSTEM FOR SECONDARY UNIT CONSTR. SERIES 050 TO 200 HOLLOW PROFILE - ALUMINIUM; 2 PER EACH SECOND. UNIT TRACK, LENGTH ACC. TO NUMBER OF SECONDARY UNITS, WITH CABLE SLEEVE NIPPLE FOR (COMBINATED) END PIECE PRICE PER SECONDARY UNIT SEGM. NUMBER = 0 + 3
SIMOTICS L COOLING SYSTEM FOR SECONDARY UNIT CONSTR. SERIES 050 TO 200 HOLLOW PROFILE - ALUMINIUM; 2 PER EACH SECOND. UNIT TRACK, LENGTH ACC. TO NUMBER OF SECONDARY UNITS, WITH CABLE SLEEVE NIPPLE FOR (COMBINATED) END PIECE PRICE PER SECONDARY UNIT SEGM. NUMBER = 0 + 4
SIMOTICS L COOLING SYSTEM FOR SECONDARY UNIT CONSTR. SERIES 050 TO 200 HOLLOW PROFILE - ALUMINIUM; 2 PER EACH SECOND. UNIT TRACK, LENGTH ACC. TO NUMBER OF SECONDARY UNITS, WITH CABLE SLEEVE NIPPLE FOR (COMBINATED) END PIECE PRICE PER SECONDARY UNIT SEGM. NUMBER = 0 + 5
SIMOTICS L COOLING SYSTEM FOR SECONDARY UNIT CONSTR. SERIES 050 TO 200 HOLLOW PROFILE - ALUMINIUM; 2 PER EACH SECOND. UNIT TRACK, LENGTH ACC. TO NUMBER OF SECONDARY UNITS, WITH CABLE SLEEVE NIPPLE FOR (COMBINATED) END PIECE PRICE PER SECONDARY UNIT SEGM. NUMBER = 0 + 6
SIMOTICS L COOLING SYSTEM FOR SECONDARY UNIT CONSTR. SERIES 050 TO 200 HOLLOW PROFILE - ALUMINIUM; 2 PER EACH SECOND. UNIT TRACK, LENGTH ACC. TO NUMBER OF SECONDARY UNITS, WITH CABLE SLEEVE NIPPLE FOR (COMBINATED) END PIECE PRICE PER SECONDARY UNIT SEGM. NUMBER = 0 + 7
SIMOTICS L COOLING SYSTEM FOR SECONDARY UNIT CONSTR. SERIES 050 TO 200 HOLLOW PROFILE - ALUMINIUM; 2 PER EACH SECOND. UNIT TRACK, LENGTH ACC. TO NUMBER OF SECONDARY UNITS, WITH CABLE SLEEVE NIPPLE FOR (COMBINATED) END PIECE PRICE PER SECONDARY UNIT SEGM. NUMBER = 0 + 8