CURRENT MEASURING MODULE; SET CURRENT 20...200A; OVERALL WIDTH 120MM; BUS BAR CONNECTION
CURRENT MEASURING MODULE; SET CURRENT 63...630A; OVERALL WIDTH 145MM; BUS BAR CONNECTION
CURRENT/VOLTAGE MEASUR. MODULE; SET CURRENT 0,3...3A; VOLTAGE DETECTION UP TO 690V; OVERALL WIDTH 45MM; STRAIGHT-THROUGH CT
Current/voltage measuring module V2; set current 0.3...4 A; voltage measurem. up to 690 V; overall width 45 mm; straight-through transformer; requires basic unit pro V PB in version -ZB01 or pro V EIP
CURRENT/VOLTAGE MEASUR. MODULE; SET CURRENT 2,4...25A; VOLTAGE DETECTION UP TO 690V; OVERALL WIDTH 45MM; STRAIGHT-THROUGH CT
Current/voltage measuring module V2; set current 3...40 A; voltage measurem. up to 690 V overall width 45 mm; straight-through transformer; requires basic unit pro V PB in version -ZB01 or pro V EIP
CURRENT/VOLTAGE MEASUR. MODULE; SET CURRENT 10...100A; VOLTAGE DETECTION UP TO 690V; OVERALL WIDTH 55MM; STRAIGHT-THROUGH CT
Current/voltage measuring module V2; set current 10...115 A; voltage measurem. up to 690 V; overall width 55 mm; straight-through transformer; requires basic unit pro V PB in version -ZB01 pro V EIP
CURRENT/VOLTAGE MEASUR. MODULE; SET CURRENT 20...200A; VOLTAGE DETECTION UP TO 690V; OVERALL WIDTH 120MM; STRAIGHT-THROUGH CT
Current/voltage measuring module V2; set current 20...200 A; voltage measurem. up to 690 V; overall width 120 mm; straight-through transformer; requires basic unit pro V PB in version -ZB01 or pro V EIP
CURRENT/VOLTAGE MEASUR. MODULE; SET CURRENT 20...200A; VOLTAGE DETECTION UP TO 690V; OVERALL WIDTH 120MM; BUS BAR CONNECTION
Current/voltage measuring module V2; set current 20...200 A; voltage measurem. up to 690 V; overall width 120 mm; busbar connection; requires basic unit pro V PB in version -ZB01 or pro V EIP
CURRENT/VOLTAGE MEASUR. MODULE; SET CURRENT 63...630A; VOLTAGE DETECTION UP TO 690V; OVERALL WIDTH 145MM; BUS BAR CONNECTION
Current/voltage measuring module V2; set current 63...630 A; voltage measurem. up to 690 V; overall width 145 mm; busbar connection; requires basic unit pro V PB in version -ZB01 or pro V EIP
DECOUPLING MODULE; F. CONNECTING IN SERIES BEFORE CURRENT/VOLTAGE MEASURING MODULE AT THE SYSTEM INTERFACE WHEN USING NON-GROUNDED NETWORKS
OPERATOR PANEL; INSTALLATION INTO CONTROL CABINET DOOR OR FRONT PLATE; CAN BE PLUGGED ONTO THE BASIC UNIT OR EXPANSION MODULE; 10 LEDS FOR STATUS DISPLAY AND 5 USER-ASSIGNABLE KEYS FOR MANUAL CONTROL
Operator panel titanium gray, installation in control cabinet door or front plate, can be plugged onto basic unit or extension modules, 10 LEDs for status display and 5 freely assignable keys for manual control
OPERATOR PANEL WITH DISPLAY; FOR SIMOCODE PRO V; INSTALLED IN CONTROL CABINET DOOR OR FRONT PLATE; CAN BE PLUGGED ONTO BASIC UNIT 2 OR EXPANSION MODULE; 7 LEDS FOR STATUS DISPLAY AND 4 USER-ASSIGNABLE KEYS FOR MANUAL CONTROL
Operator panel with display for SIMOCODE pro V, installation in control cabinet door or front plate, can be plugged onto basic unit or extension modules, 7 LEDs for status display and 4 freely assignable keys for manual control, Color: titanium gray
OPERATOR PANEL WITH DISPLAY; FOR SIMOCODE PRO V; INSTALLED IN CONTROL CABINET DOOR OR FRONT PLATE; CAN BE PLUGGED ONTO BASIC UNIT 2 OR EXPANSION MODULE; 7 LEDS FOR STATUS DISPLAY AND 4 USER-ASSIGNABLE KEYS FOR MANUAL CONTROL LANGUAGES EN/CN/RU
DIGITAL MODULE; 4 INPUTS AND 2 RELAY OUTPUTS; INPUT VOLTAGE DC 24V; MONOSTABLE RELAY OUTPUTS; MAXIMUM 2 DIGITAL MODULES PER BASIC UNIT 2
DIGITAL MODULE; 4 INPUTS AND 2 RELAY OUTPUTS; INPUT VOLTAGE AC/DC 110-240V MONOSTABLE RELAY OUTPUTS; MAXIMUM 2 DIGITAL MODULES PER BASIC UNIT 2
DIGITAL MODULE; 4 INPUTS AND 2 RELAY OUTPUTS; INPUT VOLTAGE DC 24V; BISTABLE RELAY OUTPUTS; MAXIMUM 2 DIGITAL MODULES PER BASIC UNIT 2
DIGITAL MODULE; 4 INPUTS AND 2 RELAY OUTPUTS; INPUT VOLTAGE AC/DC 110-240V; BISTABLE RELAY OUTPUTS; MAXIMUM 2 DIGITAL MODULES PER BASIC UNIT 2
FAIL-SAFE DIGITAL MODULE DM-F LOCAL; FOR FAIL-SAFE SWITCH-OFF VIA HARDWARE SIGNAL; UV: 24 V DC, 2 RELAY ENABLING CIRCUITS; 2 RELAY OUTPUTS; SAFETY FUNCTION CAN BE SELECTED VIA DIL SWITCH; MAX. ERR. SIL (IEC 61508): 3; MAX. ERR. PL (ISO 13849-1): E;
FAIL-SAFE DIGITAL MODULE DM-F LOCAL; FOR FAIL-SAFE SWITCH-OFF VIA HARDWARE SIGNAL; UV: 110...240 V AC/DC, 2 RELAY ENABLING CIRCUITS; 2 RELAY OUTPUTS; SAFETY FUNCTION CAN BE SELECTED VIA DIL SWITCH; MAX. ERR. SIL (IEC 61508): 3; MAX. ERR. PL (ISO 13849-1): E;
FAIL-SAFE DIGITAL MODULE DM-F PROFISAFE; FOR FAIL-SAFE SWITCH-OFF VIA BUS / PROFISAFE; UV: 24 V DC, 2 RELAY ENABLING CIRCUITS; 2 RELAY OUTPUTS; 3 OUTPUTS; MAX. ERR. SIL (IEC 61508): 3; MAX. ERR. PL (ISO 13849-1): E;
FAIL-SAFE DIGITAL MODULE DM-F PROFISAFE; FOR FAIL-SAFE SWITCH-OFF VIA BUS / PROFISAFE; UV: 110..240 V AC/DC, 2 RELAY ENABLING CIRCUITS; 2 RELAY OUTPUTS; 3 INPUTS; MAX. ERR. SIL (IEC 61508): 3; MAX. ERR. PL (ISO 13849-1): E;
ANALOG MODULE; 2 INPUTS AND 1 OUTPUT FOR ANALOG SIGNALS 0/4...20MA; MAXIMAL 1 ANALOG MODULE PER BASE UNIT 2
EARTH FAULT MODULE; 1 INPUT TO CONNECT A SUMMATION CURR. TRANSF. 3UL22 ;MAX. 1 EARTH FAULT MODULE PER BASE UNIT 2