SIEMENS - Motorstarter

Image
Part Number
Description
ET 200PRO DSE HF DIRECT STARTER HIGH FEATURE; MECH. SWITCHING; ELECTRO. UE PROTECTION; 3PH 400 V/5.5KW; 1.50A...12.00 BRAKE CONTACT 400 V AC; 4DI 24 V DC; HAN Q4/2 - HAN Q8/0
ET 200PRO RSE HF REVERSING STARTER HIGH FEATURE MECH. SWITCHING; ELECTRO. UE PROTECTION; 3PH 400 V/5.5KW; 1.50A...12.00 WITHOUT BRAKE CONTACT 4DI 24 V DC; HAN Q4/2 - HAN Q8/0
ET 200PRO RSE HF REVERSING STARTER HIGH FEATURE MECH. SWITCHING; ELECTRO. UE PROTECTION; 3PH 400 V/5.5KW; 1.50A...12.00 BRAKE CONTACT 400 V AC; 4DI 24 V DC; HAN Q4/2 - HAN Q8/0
ET 200PRO DSE ST DIRECT STARTER STANDARD; MECH. SWITCHING; ELECTRO. UE PROTECTION; 3PH 400 V/5.5KW; 1.50A...12.00 WITHOUT BRAKE CONTACT - HAN Q4/2 - HAN Q8/0
ET 200PRO DSE ST DIRECT STARTER STANDARD; MECH. SWITCHING; ELECTRO. UE PROTECTION; 3PH 400 V/5.5KW; 1.50A...12.00 BRAKE CONTACT 400 V AC; - HAN Q4/2 - HAN Q8/0
ET 200PRO RSE ST REVERSING STARTER STANDARD; MECH. SWITCHING; ELECTRO. UE PROTECTION; 3PH 400 V/5.5KW; 1.50A...12.00 WITHOUT BRAKE CONTACT - HAN Q4/2 - HAN Q8/0
ET 200PRO RSE ST REVERSING STARTER STANDARD; MECH. SWITCHING; ELECTRO. UE PROTECTION; 3PH 400 V/5.5KW; 1.50A...12.00 BRAKE CONTACT 400 V AC; - HAN Q4/2 - HAN Q8/0
ET 200PRO EDSE/DSSE HF ELECTRONIC DIRECT STARTER ELECTRONIC (SOFT) SWITCHING FULL MOTOR PROTECTION COMPRISING: ELECTRONIC OVERLOAD PROTECTION + THERMISTOR 3 AC 400V/5.5KW; 1.5A...(9A)12A W/O BRAKE CONTACT 4DI HAN Q4/2 - HAN Q8/0
ET 200PRO EDSE/DSSE HF ELECTRONIC DIRECT STARTER ELECTRONIC (SOFT) SWITCHING FULL MOTOR PROTECTION COMPRISING: ELECTRONIC OVERLOAD PROTECTION + THERMISTOR 3 AC 400V/5.5KW; 1.5A...(9A)12A BRAKE CONTACT AC 400V; 4DI HAN Q4/2 - HAN Q8/0
ET 200PRO ERSE/RSSE HF ELECTRONIC REVERSING STARTER ELECTRONIC (SOFT) SWITCHING FULL MOTOR PROTECTION COMPRISING: ELECTRONIC OVERLOAD PROTECTION + THERMISTOR 3 AC 400V/5.5KW; 1.5A...(9A)12A W/O BRAKE CONTACT 4DI HAN Q4/2 - HAN Q8/0
ET 200PRO ERSE/RSSE HF ELECTRONIC REVERSING STARTER ELECTRONIC (SOFT) SWITCHING FULL MOTOR PROTECTION COMPRISING: ELECTRONIC OVERLOAD PROTECTION + THERMISTOR 3 AC 400V/5.5KW; 1.5A...(9A)12A BRAKE CONTACT AC 400V; 4DI HAN Q4/2 - HAN Q8/0
SIRIUS MOTOR STARTER M200D COMMUNICATIONS MODULE PROFIBUS DP REMOVABLE BUS INTERFACE 2 X M12 WITH LOOPING POWER CONNECTION 24V 2 X 7/8" WITH LOOPING INTEGR. BUS TERMINATOR RESISTOR USING A TECHNOLOGY MODULE 3RK1395* USABLE AS MOTOR STARTER M200D WITH COMM.
D-O-L starter electronic switching electr. overload protection up to 0.25 kW / 400 V; 0.3A..1A Option: 3DI/LC High Feature module PROFIenergy
D-O-L starter electronic switching electr. overload protection up to 1.1 kW / 400 V; 0.9A...3A Option: 3DI/LC High Feature module PROFIenergy
DOL starter Electronic switching Electronic overload protection up to 4 kW / 400 V, 2.8 A to 9 A Option: 3DI/LC module PROFIenergy
Fail-safe direct-on-line starter Electronic switching Electronic overload protection up to 0.25 kW/400 V 0.3 A to 1 A High-Feature option: 3DI/LC module PROFIenergy
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE DIRECT ON-LINE STARTER, BASIC MECHANICAL SWITCHING 3 400V AC/0,9KW;0,15A...2,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR:THERMOCLICK / PTC WITHOUT BRAKE CONTACT 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE DIRECT ON-LINE STARTER BASIC MECHANICALLY SWITCHING 3 400V AC/0.9KW; 0.15A...2.00A; ELECTRONIC OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITH BRAKE CONTACT 400V/230V AC 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE DIRECT ON-LINE STARTER, BASIC MECHANICAL SWITCHING 3 400V AC/0,9KW; 0,15A...2,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITH BRAKE CONTACT 180V DC 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE REVERSING STARTER, BASIC MECHANICAL SWITCHING 3 400V AC/0,9KW; 0,15A...2,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITHOUT BRAKE CONTACT 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE REVERSING STARTER BASIC MECHANICALLY SWITCHING 3 400V AC/0.9KW; 0.15A...2.00A; ELECTRONIC OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITH BRAKE CONTACT 400V AC 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE REVERSING STARTER, BASIC MECHANICAL SWITCHING 3 400V AC/0,9KW; 0,15A...2,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITH BRAKE CONTACT 180V DC 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE DIRECT ON-LINE STARTER, BASIC MECHANICAL SWITCHING 3 400V AC/0,9KW; 0,15A...2,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITHOUT BRAKE CONTACT 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0 WITH OPERATOR TERMINAL AND KEY-OPERATED SWITCH
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE DIRECT ON-LINE STARTER, BASIC MECHANICAL SWITCHING 3 400V AC/0,9KW; 0,15A...2,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITH BRAKE CONTACT 400V AC 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0 WITH OPERATOR TERMINAL AND KEY-OPERATED SWITCH
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE DIRECT ON-LINE STARTER, BASIC MECHANICAL SWITCHING 3 400V AC/0,9KW; 0,15A...2,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITH BRAKE CONTACT 180V DC 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0 WITH OPERATOR TERMINAL AND KEY-OPERATED SWITCH
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE REVERSING STARTER, BASIC MECHANICAL SWITCHING 3 400V AC/0,9KW; 0,15A...2,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITHOUT BRAKE CONTACT 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0 WITH OPERATOR TERMINAL AND KEY-OPERATED SWITCH
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE REVERSING STARTER BASIC MECHANICALLY SWITCHING 3 400V AC/0.9KW; 0.15A...2.00A; ELECTRONIC OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITH BRAKE CONTACT 400V AC 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0 WITH OPERATOR TERMINAL AND KEY-OPERATED SWITCH
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE REVERSING STARTER, BASIC MECHANICAL SWITCHING 3 400V AC/0,9KW; 0,15A...2,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITH BRAKE CONTACT 180V DC 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0 WITH OPERATOR TERMINAL AND KEY-OPERATED SWITCH
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE DIRECT ON-LINE STARTER, BASIC ELECTR. SWITCHING 3 400V AC/0,9KW; 0,15A...2,00A; ELECTR. OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITHOUT BRAKE CONTACT 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0
SIRIUS MOTOR STARTER M200D AS-I COMMUNICATION: AS-INTERFACE DIRECT ON-LINE STARTER BASIC ELECTRONICALLY SWITCHING 3 400V AC/0.9KW; 0.15A...2.00A; ELECTRONIC OVERLOAD PROTECTION; THERMISTOR: THERMOCLICK / PTC WITH BRAKE CONTACT 400V AC 2DI AS-I + 2DI / 1DO ON DEVICE HAN Q4/2 - HAN Q8/0
Menu
Mail Us
enquiry@onstocktrading.com