SIEMENS - Motors for Motion Control

Image
Part Number
Description
SIMOTICS L COMBINED ADAPTER FOR FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR INFLOW AND OUTFLOW OF WATER AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L COMBINED CROSS CONNECTOR; FRAME SIZE 050; WITH COUPLING; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR WATER DISTRIBUTION AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED; LENGHT 2M; FN=150N; FMAX=260N; VMAX_FN=435M/MIN; VMAX=242M/MIN; IN=2,8A; IMAX=5,9A"
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED;LENGTH 0,5M; POWER CABLE WITH PLUG SIZE 1; SIGNAL CABLE WITH PLUG SIZE M17; FN=150N; FMAX=260N; VMAX_FN=435M/MIN; VMAX_FMAX=242M/MIN; IN =2,8A; IMAX=5,9A; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRECISION COOLER FOR PRIMARY SECTION 1FN3050-1N... COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED;LENGTH 2M FN=300N; FMAX=510N; VMAX_FN=202M/MIN; VMAX=106M/MIN; IN=2,8A; IMAX=5,9A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED;LENGTH 0,5M; POWER CABLE WITH PLUG SIZE 1; SIGNAL CABLE WITH PLUG SIZE M17; FN=300N; FMAX=510N; VMAX_FN=202M/MIN; VMAX_FMAX=106M/MIN; IN=2,8A; IMAX=5,9A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRECISION COOLER FOR PRIMARY SECTION 1FN3050-2W... COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
SIMOTICS L PRECISION COOLER FOR PRIMARY SECTION 1FN3050-2N... COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED;LENGTH 2M; FN=200N; FMAX=550N; VMAX_FN=373M/MIN; VMAX_FMAX=146M/MIN; IN=2,7A; IMAX=8,2A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED;LENGTH 0,5M; POWER CABLE WITH PLUG SIZE 1; SIGNAL CABLE WITH PLUG SIZE 0,5; FN=200N; FMAX=550N; VMAX_FN=373M/MIN; VMAX_FMAX=146M/MIN; IN=2,7A; IMAX=8,2A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED;LENGTH 2M; FN=200N; FMAX=550N; VMAX_FN=373M/MIN; VMAX_FMAX=146M/MIN; IN=2,7A; IMAX=8,2A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L SECONDARY SECTION FOR LINEAR MOTOR 1FN3; FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; LENGTH 120 MM
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 2,5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3,5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 4 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 050; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 5 SECONDARY SECTION SEGMENTS
SIMOTICS L COVER BAND FOR ONE SECONDARY SECTION TRACK; FRAME SIZE 100; COLD-ROLLED SHEET (0,4MM); PRICE PER SECONDARY SECTION SEGMENT; LENGTH IN NUMBER OF SECONDARY SECTIONS = 20 + 2
SIMOTICS L END PIECE FOR SECONDARY UNIT WITH RETAINING DEV. FOR COVER COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
SIMOTICS L COMBINED END-PIECE FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR WATER-REDIRECTION AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L COMBINED ADAPTER FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR INFLOW AND OUTFLOW OF WATER AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L COMBINED CROSS CONNECTOR; FRAME SIZE 100; WITH COUPLING; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR WATER DISTRIBUTION AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; STYLE DEPT CONTINUOUS LOAD SPECIFICATION; SEPARATE CONNECTION OF POWER AND SIGNAL; COVER PREPARED FOR METRIC SCREW GLAND; FN=300N; FMAX=510N; VMAX_FN=214M/MIN; VMAX=117M/MIN; IN=2,9A; IMAX=5,9A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. VIOLATED.
SIMOTICS L PRECISION COOLER FOR PRIMARY SECTION 1FN3100-1N... COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=200N; FMAX=490N; VMAX_FN=322M/MIN; VMAX=138M/MIN; IN=2,4A; IMAX=6,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=200N; FMAX=490N; VMAX_FN=322M/MIN; VMAX_FMAX=138M/MIN; IN=2,4A; IMAX=6,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. VIOLATED.
SIMOTICS L PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED; LENGTH 2M; FN=605N; FMAX=1020N; VMAX_FN=307M/MIN; VMAX=170M/MIN IN=8A; IMAX=16,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
SIMOTICS L PRECISION COOLER FOR PRIMARY SECTION 1FN3100-2W... COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
SIMOTICS L PRECISION COOLER FOR PRIMARY SECTION 1FN3100-2N... COMPONENT 3-PHASE SYNCHRONOUS MOTOR;
Menu
Mail Us
enquiry@onstocktrading.com