SAFETY POS. SWITCH WITH TUMBLER LOCKING FORCE 1300N, 5 DIRECTIONS OF APPROACH PLASTIC ENCLOSURE, M12 PLUG, ASISAFE INTEGRATED CHAN1=TO 1NC FROM ACTUATOR CHAN2=TO 1NC FROM ACTUATOR SOLENOID-LOCKED, SOLENOID VOLTAGE 24V DC/AC, MONITORING OF ACTUATOR 2NC/1NO, MONITORING OF SOLENOID 2NC/1NO, A SUITABLE SEPARATE ACTUATOR 3SE5000-0AV0. MUST BE ORDERED SEPARATELY
SAFETY POSITION SWITCHES WITH SOLENOID INTERLOCKING LOCKING FORCE 1500N, 5 DIRECTIONS OF APPROACH PLASTIC ENCLOSURE, M12 CONNECT. ASISAFE INTEGRATED CH1=ACTUATOR 1NC, CH2=MAGNET 1NC SPRING-ACTUATED LOCK, AUXIL. RELEASE ON FRONT MAGNET VOLTAGE 24 V DC/AC, MONITORING ACTUATOR 2NC/1NO, MONITORING MAGNET 2NC/1NO, THE MATCHING SEPARATE ACTUATOR 3SE5000-0AV0. IS TO BE ORDERED SEPARATELY
SAFETY POSITION SWITCHES WITH SOLENOID INTERLOCKING LOCKING FORCE 1300N, 5 DIRECTIONS OF APPROACH PLASTIC ENCLOSURE, M12 CONNECT. ASISAFE INTEGRATED CH1 AND CH2=ACTUATOR 2NC, SPRING-ACTUATED LOCK, AUXIL. RELEASE ON FRONT MAGNET VOLTAGE 24 V DC/AC, MONITORING ACTUATOR 2NC/1NO, MONITORING MAGNET 2NC/1NO, THE MATCHING SEPARATE ACTUATOR 3SE5000-0AV0. IS TO BE ORDERED SEPARATELY
SAFETY POSITION SWITCH WITH SOLENOID INTERLOCKING LOCKING FORCE 1300N, 5 DIRECTIONS OF APPROACH PLASTIC ENCLOSURE, M12 CONNECT. ASISAFE INTEGRATED CH1 =ACTUATOR 2NC, ACC.TO 2-OUT-OF-2 EVALUATION, CH2=MAGNET 1NC SPRING-ACTUATED LOCK,AUXIL. RELEASE ON FRONT MAGNET VOLTAGE 24 V DC/AC, MONITORING ACTUATOR 2NC/1NO, MONITORING MAGNET 2NC/1NO, THE MATCHING SEPARATE ACTUATOR 3SE5000-0AV0. IS TO BE ORDERED SEPARATELY
SAFETY POS. SWITCH W. TUMBLER HIGH DEG. OF PROTECTION IP69,IEC 60529 LOCKING FORCE 1300N, 5 DIRECTIONS OF APPROACH PLASTIC ENCLOSURE, M12 CONNECTOR, ASI-SAFE INTEGRATED CH1 =ACTUATOR 2NC, ACC.TO 2-OUT-OF-2 EVALUATION, CH2=SOLENOID 1NC SPRING-LOCKED, AUXILIARY RELEASE ON FRONT SOLENOID VOLTAGE 24 V DC/AC, MONITORING ACTUATOR 2NC/1NO, MONITORING SOLENOID 2NC/1NO, THE MATCHING SEPARATE ACTUATOR 3SE5000-0AV0. MUST BE ORDERED SEPARATELY
SAFETY POSITION SWITCHES WITH SOLENOID INTERLOCKING LOCKING FORCE 1300N, 5 DIRECTIONS OF APPROACH PLASTIC ENCLOSURE, M12 CONNECT. ASISAFE INTEGRATED CH1=ACTUATOR 1NC, CH2=MAGNET 1NC SPRING-ACTUATED LOCK, AUXIL. RELEASE W/LOCK ON FRONT, MAGNET VOLTAGE 24 V DC/AC, MONITORING ACTUATOR 2NC/1NO, MONITORING MAGNET 2NC/1NO, THE MATCHING SEPARATE ACTUATOR 3SE5000-0AV0. IS TO BE ORDERED SEPARATELY
SAFETY POSITION SWITCHES WITH SOLENOID INTERLOCKING LOCKING FORCE 1300N, 5 DIRECTIONS OF APPROACH PLASTIC ENCLOSURE, M12 CONNECT. ASISAFE INTEGRATED CH1=ACTUATOR 1NC, CH2=MAGNET 1NC SPRING-ACTUATED LOCK, ESCAPE RELEASE ON FRONT, MAGNET VOLTAGE 24 V DC/AC, MONITORING ACTUATOR 2NC/1NO, MONITORING MAGNET 2NC/1NO, THE MATCHING SEPARATE ACTUATOR 3SE5000-0AV0. IS TO BE ORDERED SEPARATELY
SAFETY POSITION SWITCH WITH SOLENOID INTERLOCKING LOCKING FORCE 1300N, 5 DIRECTIONS OF APPROACH PLASTIC ENCLOSURE, M12 CONNECT. ASISAFE INTEGRATED CH1=ACTUATOR 2NC, ACC.TO 2-OUT-OF-2 EVALUATION, CH2=MAGNET 1NC SPRING-ACTUATED LOCK, ESCAPE RELEASE ON REAR AND AUXIL. RELEASE ON FRONT, MAGNET VOLTAGE 24 V DC/AC, MONITORING ACTUATOR 2NC/1NO, MONITORING MAGNET 2NC/1NO, THE MATCHING SEPARATE ACTUATOR 3SE5000-0AV0. IS TO BE ORDERED SEPARATELY
SAFETY POS. SWITCH W. TUMBLER HIGH DEG. OF PROTECTION IP69,IEC 60529 LOCKING FORCE 1300N, 5 DIRECTIONS OF APPROACH PLASTIC ENCLOSURE, M12 CONNECTOR, ASI-SAFE INTEGRATED CH1 =ACTUATOR 2NC, ACC.TO 2-OUT-OF-2 EVALUATION, CH2=SOLENOID 1NC SPRING-LOCKED, ESCAPE RELEASE ON FRONT SOLENOID VOLTAGE 24 V DC/AC, MONITORING ACTUATOR 2NC/1NO, MONITORING SOLENOID 2NC/1NO, THE MATCHING SEPARATE ACTUATOR 3SE5000-0AV0. MUST BE ORDERED SEPARATELY
SAFETY POSITION SWITCHES WITH SOLENOID INTERLOCKING LOCKING FORCE 1300N, 5 DIRECTIONS OF APPROACH PLASTIC ENCLOSURE, M12 CONNECT. ASISAFE INTEGRATED CH1=ACTUATOR 1NC, CH2=MAGNET 1NC SPRING-ACTUATED LOCK, ESCAPE RELEASE ON REAR AND AUXIL. RELEASE ON FRONT, MAGNET VOLTAGE 24 V DC/AC, MONITORING ACTUATOR 2NC/1NO, MONITORING MAGNET 2NC/1NO, THE MATCHING SEPARATE ACTUATOR 3SE5000-0AV0. IS TO BE ORDERED SEPARATELY
SAFETY POSITION SWITCH WITH SOLENOID INTERLOCKING LOCKING FORCE 1300N, 5 DIRECTIONS OF APPROACH PLASTIC ENCLOSURE, M12 CONNECT. ASISAFE INTEGRATED CH1=ACTUATOR 2NC, ACC.TO 2-OUT-OF-2 EVALUATION, CH2=MAGNET 1NC SPRING-ACTUATED LOCK, ESCAPE RELEASE ON REAR AND AUXIL. RELEASE ON FRONT, MAGNET VOLTAGE 24 V DC/AC, MONITORING ACTUATOR 2NC/1NO, MONITORING MAGNET 2NC/1NO, THE MATCHING SEPARATE ACTUATOR 3SE5000-0AV0. IS TO BE ORDERED SEPARATELY
SAFETY POS. SWITCH W. TUMBLER DEGREE OF PROTECTION IP69,IEC 60529 LOCKING FORCE 1300N, 5 DIRECTIONS OF APPROACH PLASTIC ENCLOSURE, M12 CONNECTOR, ASI-SAFE INTEGRATED CH1 =ACTUATOR 2NC, ACC.TO 2-OUT-OF-2 EVALUATION, CH2=SOLENOID 1NC SPRING-LOCKED, ESCAPE RELEASE ON REAR AND AUXILIARY RELEASE ON FRONT SOLENOID VOLTAGE 24 V DC/AC, MONITORING ACTUATOR 2NC/1NO, MONITORING SOLENOID 2NC/1NO, THE MATCHING SEPARATE ACTUATOR 3SE5000-0AV0. MUST BE ORDERED S
SAFETY POSITION SWITCHES WITH SOLENOID INTERLOCKING LOCKING FORCE 1300N, 5 DIRECTIONS OF APPROACH PLASTIC ENCLOSURE, M12 CONNECT. ASISAFE INTEGRATED CH1=ACTUATOR 1NC, CH2=MAGNET 1NC SPRING-ACTUATED LOCK, EMERGENCY RELEASE ON REAR AND AUXIL. RELEASE ON FRONT, MAGNET VOLTAGE 24 V DC/AC, MONITORING ACTUATOR 2NC/1NO, MONITORING MAGNET 2NC/1NO, THE MATCHING SEPARATE ACTUATOR 3SE5000-0AV0. IS TO BE ORDERED SEPARATELY
SAFETY CABLE-OPER. SWITCH METAL,WITH LATCH., EN418, 2NC BUTTON RESET, UP TO 10M CABLES, M. ASI-F-ADAPTER,SAFETY AT WORK CHAN.1 TO 11-12,CHAN.2 TO 21-22
SAFETY CABLE OPERATED SWITCH METAL, WITH LATCHING TO EN418 PUSHBUTTON RESET, 50 M CABLE, W. ASI-F ADAPTER SAFETY AT WORK CHAN.1 AT 11-12,CHAN.2 AT 21-22
SAFETY CABLE OPERATED SWITCH METAL, LATCHING TO EN418, 2NC PUSHBUTTON RESET, 25 M CABLE, W. ASI-F ADAPTER SAFETY AT WORK CHAN.1 AT 11-12,CHAN.2 AT 21-22
AS-I ENCLOSURE, 22MM PROGRAM 1 COMMAND POSITION PLASTIC VERSION YELLOW ENCLOSURE TOP PART WITHOUT PROTECTIVE COLLAR A=AS-I EMERGEN.-STOP, SAFETY AT WORK, 2NC