ANALOG INPUT MODULE CURRENT IP67 S7 ANALOG, 2AI, NUMERIC. FORMAT S7 2 X INP. (M12), 4 TO 20MA FOR 4-WIRE SENSORS ACTIVE CHANNELS 1 AND 2 MOUNTING PLATE 3RK19010CA00 TO BE ORDERED SEPARATELY
AS-INTERFACE COMPACT MOD., IP67 ANALOG, 2AI, NUMERIC. FORMAT S7 2 X INP. (M12), 4 TO 20MA FOR 4-WIRE SENSORS ACTIVE CHANNELS 1 AND 2 MOUNTING PLATE 3RK19010CA00 TO BE ORDERED SEPARATELY
AS-INTERF. COMPACT MODULE, IP67 ANALOG, 4AI 4 X INPUTS (M12), 4...20MA FOR 4-WIRE SENSORS ACTIVE CHANNELS 1,2, 3 A. 4 MOUNTING PLATE 3RK19010CA00 TO BE ORDERED SEPARATELY, PROFILE 7.3
AS-INTERFACE COMPACT MOD., IP67 ANALOG, 2AI, NUMERIC. FORMAT S7 2 X INP. (M12), +/- 10V FOR 2-WIRE SENSORS ACTIVE CHANNELS 1 AND 2 MOUNTING PLATE 3RK19010CA00 TO BE ORDERED SEPARATELY
AS-INTERF. COMPACT MODULE, IP67 ANALOG, 4AI 4 X INPUTS (M12), +/-10V FOR 2-WIRE SENSORS ACTIVE CHANNELS 1,2, 3 A. 4 MOUNTING PLATE 3RK19010CA00 TO BE ORDERED SEPARATELY, PROFILE 7.3
AS-INTERFACE COMPACT MOD., IP67 ANALOG, 2AI, NUMERIC. FORMAT S7 2 X INP. (M12), PT100 LIN. ST. FOR 4-WIRE SENSORS ACTIVE CHANNELS 1 AND 2 MOUNTING PLATE 3RK19010CA00 TO BE ORDERED SEPARATELY
AS-INTERFACE COMPACT MOD., IP67 ANALOG, 2AI, NUMERIC. FORMAT S7 2 X INP. (M12), PT100 LIN. ST. FOR 2-WIRE SENSORS ONLY ACTIVE CHANNELS 1 AND 2 MOUNTING PLATE 3RK19010CA00 TO BE ORDERED SEPARATELY
AS-INTERF. COMPACT MODULE, IP67 ANALOG, 4AI 4 X INP. (M12), PT100 LIN. ST. FOR 4-WIRE SENSORS ACTIVE CHANNELS 1,2, 3 A. 4 MOUNTING PLATE 3RK19010CA00 TO BE ORDERED SEPARATELY, PROFILE 7.3
DS1E-X FOR ET200S HIGH FEATURE DIRECT STARTER SETTING RANGE 0.3...3A MECHANICAL SWITCHING ELECTRONIC CONTACTOR AC-3/TO 1.1KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE MOTORSTARTER ES SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE DPV 1 CAPABLE PROFIENERGY CAPABLE ON PN
RS1E-X FOR ET200S HIGH FEATURE REVERSING STARTER SETTING RANGE 0.3...3A MECHANICAL SWITCHING ELECTRONIC PROTECTION AC-3/TO 1.1KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE 2DI MODULE SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE DPV 1 CAPABLE PROFIENERGY CAPABLE ON PN
F-DS1E-X FOR ET 200S FAILSAFE DIRECT STARTER SETTING RANGE 0.3...3A MECHANICAL SWITCHING ELECTRONIC PROTECTION AC-3, TO 1.1KW/400V, CAN BE EXPANDED FOR BRAKE CONTROL MODULE FOR 2DI CONTROL MODULE
F-DS1E-X FOR ET 200S FAILSAFE DIRECT STARTER SETTING RANGE 0.3...3A MECHANICAL SWITCHING ELECTRONIC PROTECTION EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE
F-RS1E-X FOR ET 200S FAILSAFE REVERSING STARTER SETTING RANGE 0.3...3A MECHANICAL SWITCHING ELECTRONIC PROTECTION AC-3, TO 1.1KW/400V, CAN BE EXPANDED FOR BRAKE CONTROL MODULE FOR 2DI CONTROL MODULE
DSS1E-X FOR ET200S HIGH FEAT. DIRECT SOFT STARTER SETTING RANGE 0.3...3A SWITCH ELECTRONICALLY PROTECT ELECTRONICALLY AC-3/UP TO 1.1KW/400V EXPANDABLE FOR BRAKE CONTROL MOD. 2DI MOD. MOTOR STARTER ES
DSS1E-X FOR ET200S HIGH FEATURE DIRECT SOFT STARTER SETTING RANGE 0.3...3A MECHANICAL SWITCHING ELECTRONIC PROTECTION AC-3/TO 1.1KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE MOTORSTARTER ES SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE
DS1E-X FOR ET200S HIGH FEATURE DIRECT STARTER SETTING RANGE 2.4...8A MECHANICAL SWITCHING ELECTRONIC PROTECTION AC-3/TO 3KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE 2DI MODULE MOTORSTARTER ES SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE DPV 1 CAPABLE PROFIENERGY CAPABLE ON PN
RS1E-X FOR ET200S HIGH FEATURE REVERSING STARTER SETTING RANGE 2.4...8A MECHANICAL SWITCHING ELECTRONIC PROTECTION AC-3/BIS 3KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE 2DI MODULE MOTORSTARTER ES SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE
F-DS1E-X FOR ET 200S FAILSAFE DIRECT STARTER SETTING RANGE 2.4...8A, MECHANICAL SWITCHING ELECTRONIC PROTECTION AC-3, TO 3KW/400V, CAN BE EXPANDED FOR BRAKE CONTROL MODULE FOR 2DI CONTROL MODUL
F-DS1E-X FOR ET 200S FAILSAFE DIRECT STARTER SETTING RANGE 2.4...8A MECHANICAL SWITCHING ELECTRONIC PROTECTION AC-3/TO 3KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE 2DI MODULE SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE
F-RS1E-X FOR ET 200S FAILSAFE REVERSING STARTER SETTING RANGE 2.4...8A, MECHANICAL SWITCHING, ELECTRONIC TROTECTION, AC-3, TO 3KW/400V, CAN BE EXPANDED FOR BRAKE CONTROL MODULE FOR 2DI CONTROL MODUL
F-RS1E-X FOR ET 200S FAILSAFE REVERSING STARTER SETTING RANGE 2.4...8A MECHANICAL SWITCHING ELECTRONIC PROTECTION AC-3/TO 3KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE 2DI MODULE SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE
DSS1E-X FOR ET200S HIGH FEAT. DIRECT SOFT STARTER SETTING RANGE 2.4...8A SWITCH ELECTRONICALLY PROTECT ELECTRONICALLY AC-3/UP TO 3KW/400V EXPANDABLE FOR BRAKE CONTROL MOD. 2DI MOD. MOTOR STARTER ES
DSS1E-X FOR ET200S HIGH FEATURE DIRECT SOFT STARTER SETTING RANGE 2.4...8A ELECTRONIC SWITCHING ELECTRONIC PROTECTION AC-3/TO 3KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE MOTORSTARTER ES SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE
DSS1E-X FOR ET200S HIGH FEATURE DIRECT SOFT STARTER SETTING RANGE 2.4...8A ELECTRONIC SWITCHING ELECTRONIC PROTECTION AC-3/TO 3KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE MOTORSTARTER ES SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE DPV 1 CAPABLE PROFIENERGY CAPABLE ON PN
DS1E-X FOR ET200S HIGH FEATURE DIRECT STARTER SETTING RANGE 2.4...16A SWITCH MECHANICALLY PROTECT ELECTRONICALLY AC-3/UP TO 7.5KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE MOTOR STARTER ES
DS1E-X FOR ET200S HIGH FEATURE DIRECT STARTER SETTING RANGE 2.4...16A MECHANICAL SWITCHING ELECTRONIC PROTECTION AC-3/TO 7.5KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE 2DI MODULE MOTORSTARTER ES SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE DPV 1 CAPABLE PROFIENERGY CAPABLE ON PN