SIEMENS - Load Feeders and Motor Starters

Image
Part Number
Description
LOAD FEEDER FUSELESS DIRECT STARTING,AC 400V,SIZE S2 28...40 A, AC 110 V, 50 HZ, SCREW CONNECTION, ON ADAPTER FOR SCREW AND SNAP-ON MOUNTING TYPE OF COORDIN. 2, IQ = 50 KA
LOAD FEEDER FUSELESS DIRECT STARTING,AC 400V,SIZE S2 28...40 A, AC 230 V, 50 HZ, SCREW CONNECTION, ON ADAPTER FOR SCREW AND SNAP-ON MOUNTING TYPE OF COORDIN. 2, IQ = 50 KA
LOAD FEEDER FUSELESS DIRECT STARTING,AC 400V,SIZE S2 28...40 A, DC 24 V, ON ADAPTER FOR SCREW AND SNAP-ON MOUNTING TYPE OF COORDIN. 2, IQ = 50 KA (ALSO COMPATIBLE WITH TYPE OF COORDINATION 1)
LOAD FEEDER FUSELESS DIRECT STARTING,AC 400V,SIZE S2 36...45 A, AC 24 V, 50 HZ, SCREW CONNECTION, ON ADAPTER FOR SCREW AND SNAP-ON MOUNTING TYPE OF COORDIN. 2, IQ = 50 KA
LOAD FEEDER FUSELESS DIRECT STARTING,AC 400V,SIZE S2 36...45 A, AC 110 V, 50 HZ, SCREW CONNECTION, ON ADAPTER FOR SCREW AND SNAP-ON MOUNTING TYPE OF COORDIN. 2, IQ = 50 KA
LOAD FEEDER FUSELESS DIRECT STARTING,AC 400V,SIZE S2 36...45 A, AC 230 V, 50 HZ, SCREW CONNECTION, ON ADAPTER FOR SCREW AND SNAP-ON MOUNTING TYPE OF COORDIN. 2, IQ = 50 KA
LOAD FEEDER FUSELESS DIRECT STARTING,AC 400V,SIZE S2 36...45 A, DC 24 V, ON ADAPTER FOR SCREW AND SNAP-ON MOUNTING TYPE OF COORDIN. 2, IQ = 50 KA (ALSO COMPATIBLE WITH TYPE OF COORDINATION 1)
LOAD FEEDER FUSELESS DIRECT STARTING,AC 400V,SIZE S2 40...50 A, AC 110 V, 50 HZ, SCREW CONNECTION, ON ADAPTER FOR SCREW AND SNAP-ON MOUNTING TYPE OF COORDIN. 2, IQ = 50 KA
LOAD FEEDER FUSELESS DIRECT STARTING,AC 400V,SIZE S2 40...50 A, AC 230 V, 50 HZ, SCREW CONNECTION, ON ADAPTER FOR SCREW AND SNAP-ON MOUNTING TYPE OF COORDIN. 2, IQ = 50 KA
LOAD FEEDER FUSELESS DIRECT STARTING,AC 400V,SIZE S2 40...50 A, DC 24 V, ON ADAPTER FOR SCREW AND SNAP-ON MOUNTING TYPE OF COORDIN. 2, IQ = 50 KA (ALSO COMPATIBLE WITH TYPE OF COORDINATION 1)
LOAD FEEDER FUSE LINE DIREKTANLAUF, 400 V AC, SIZES2, 22...32A, 24 V DC, SCREW CONNECTION, ON ADAPTER FOR SCREW AND SNAP FIXING, ASSIGN. TYPE 2, IQ = 50KA, (COMPLY ALSO W. ASSIGN. TYPE 1) BUILT-ON AUX. SWITCHES FOR LS 3RV19011E
LOAD FEEDER FUSE LINE DIRECT START, 400 V AC, SIZE S2 28...40 A, 230 V AC, 50 HZ, SCREW CONNECTION 1NO+1NC (CIRCUIT-BREAKER) FOR SCREW AND SNAP FIXING ASSIGN. TYPE 2, IQ = 50 KA (COMPLY ALSO ASSIGN. TYPE 1)
LOAD FEEDER, FUSELESS DIRECT START, AC 400V, SIZE S2, 22...32A, AC 100V, 50/60HZ, SCREW CONNECTION FOR DIN RAIL MOUNTING, IQ = 50KA 1NO+1NC (CIRCUIT BREAKER)
LOAD FEEDER, FUSELESS DIRECT START, AC 400V, SIZE S2, 22...32A, DC 400V, 50/60HZ, SCREW CONNECTION FOR DIN RAIL MOUNTING, IQ = 50KA 1NO+1NC (CIRCUIT BREAKER)
LOAD FEEDER, FUSELESS DIRECT START, AC 400V, SIZE S2, 40...50A, AC 110V, 50HZ, SCREW CONNECTION FOR DIN RAIL MOUNTING, IQ = 50KA 1NO+1NC (CIRCUIT BREAKER)
LOAD FEEDER, FUSELESS DIRECT START, AC 400V, SIZE S2, 40...50A, DC 400V, 50/60HZ, SCREW CONNECTION FOR DIN RAIL MOUNTING, IQ = 50KA 1NO+1NC (CIRCUIT BREAKER)
LOAD FEEDER FUSELESS DIRECT START, AC 400V, SZ.S2, 18...25A ; DC 24V 1NO (CONTACTOR), SCREW-TYPE TERMINAL MOUNTING RAIL ADAPTER TYPE OF COORDINATION 2, IQ = 50KA CONTACTOR WITH CC COIL 1NO+1NC (AS MCB SPRING-LOADED) 2NO+2NC (AS CONTACTOR SPRING-LOADED)
LOAD FEEDER FUSELESS DIRECT START, AC 400V, SZ.S2, 22...32A ; DC 24V 1NO (CONTACTOR), SCREW-TYPE TERMINAL MOUNTING RAIL ADAPTER TYPE OF COORDINATION 2, IQ = 50KA CONTACTOR WITH CC COIL 1NO+1NC (AS MCB SPRING-LOADED) 2NO+2NC (AS CONTACTOR SPRING-LOADED)
LOAD FEEDER, FUSELESS DIRECT START, AC 400V, SIZE S3, 45...63A, AC 110V, 50HZ, SCREW CONNECTION FOR DIN RAIL MOUNTING, IQ = 50KA 1NO+1NC (CIRCUIT BREAKER)
LOAD FEEDER, FUSELESS DIRECT START, AC 400V, SIZE S3, 57...75A, AC 110V, 50HZ, SCREW CONNECTION FOR DIN RAIL MOUNTING, IQ = 50KA 1NO+1NC (CIRCUIT BREAKER)
LOAD FEEDER, FUSELESS DIRECT START, AC 400V, SIZE S3, 57...75A, DC 400V, 50/60HZ, SCREW CONNECTION FOR DIN RAIL MOUNTING, IQ = 50KA 1NO+1NC (CIRCUIT BREAKER)
LOAD FEEDER, FUSELESS DIRECT START, AC 400V, SIZE S3, 70...90A, AC 110V, 50HZ, SCREW CONNECTION FOR DIN RAIL MOUNTING, IQ = 50KA 1NO+1NC (CIRCUIT BREAKER)
LOAD FEEDER, FUSELESS DIRECT START, AC 400V, SIZE S3, 80...100A, AC 110V, 50HZ, SCREW CONNECTION FOR DIN RAIL MOUNTING, IQ = 50KA 1NO+1NC (CIRCUIT BREAKER)
LOAD FEEDER, FUSELESS DIRECT START, AC 400V, SIZE S3, 80...100A, DC 400V, 50/60HZ, SCREW CONNECTION FOR DIN RAIL MOUNTING, IQ = 50KA 1NO+1NC (CIRCUIT BREAKER)
LOAD FEEDER FUSELESS REVERSING DUTY, AC 400 V, SIZES00, 0.14...0.2 A, AC 230V SCREW CONNECTION,. TYPE OF COORDIN. 2, IQ = 50 KA
LOAD FEEDER FUSELESS REVERSING DUTY, AC 400 V, SIZES00, 0.14...0.2 A, DC 24V SCREW CONNECTION TYPE OF COORDIN. 2, IQ = 50 KA
LOAD FEEDER FUSELESS REVERSING DUTY, AC 400 V, SIZES00, 0.14...0.2 A, AC 230V SCREW CONNECTION, TYPE OF COORDIN. 2, IQ = 50 KA ON 40 MM BUSBAR ADAPTER
LOAD FEEDER FUSELESS REVERSING DUTY, AC 400 V, SIZES00, 0.14...0.2 A, DC 24 V SCREW CONNECTION, TYPE OF COORDIN. 2, IQ = 50 KA ON 40 MM BUSBAR ADAPTER
LOAD FEEDER FUSELESS REVERSING DUTY, AC 400 V, SIZES00, 0.14...0.2 A, AC 230V SCREW CONNECTION, TYPE OF COORDIN. 2, IQ = 50 KA ON 60 MM BUSBAR ADAPTER
LOAD FEEDER FUSELESS REVERSING DUTY, AC 400 V, SIZES00, 0.14...0.2 A, DC 24 V SCREW CONNECTION, TYPE OF COORDIN. 2, IQ = 50 KA ON 60 MM BUSBAR ADAPTER
Menu