SIEMENS - Circuit breakers

Image
Part Number
Description
ACCESSORY FOR VL250, CIRCULAR COND. TERMINAL COMPRISES 3 CIRC. CONDUCTOR TERMINALS AND TERMINAL COVER 3-POLE
ACCESSORY FOR VL250, CIRCULAR COND. TERMINAL COMPRISES 4 CIRC. CONDUCTOR TERMINALS AND TERMINAL COVER 4-POLE
ACCESSORY FOR VL250, RCD MODULE IN=250A UE=127...480V 3 POLE
ACCESSORY FOR VL250, RCD MODULE IN=250A UE=127...480V 4 POLE
ACCESSORY FOR VL250, RCD MODULE IN=250A UE=230...690V 3 POLE
ACCESSORY FOR VL250, RCD MODULE IN=250A UE=230...690V 4 POLE
ELECTRONIC TRIP UNIT VL 250 4-POLE, PLANT PROTECTION ETU10, LI IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION, N-PROTECTED SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL FOR LRS, DNV AND GL
ELECTRONIC TRIP UNIT VL 250 3-POLE, PLANT PROTECTION ETU10, LI IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL FOR LRS, DNV AND GL
ELECTRONIC TRIP UNIT VL 250 3-POLE, PLANT PROTECTION ETU20, LSI IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL FOR LRS, DNV AND GL
ELECTRONIC TRIP UNIT VL 250 4-POLE, PLANT PROTECTION ETU20, LSI IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION, N-PROTECTED SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL FOR LRS, DNV AND GL
ELECTRONIC TRIP UNIT VL 250 3-POLE, MOTOR PROTECTION ETU30M, LI IR= 100...250A, OVERLOAD PROTECTION, TC= 10A ... 30,TIME LAG CLASS II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION SCREW CONNECTIONS INCLUDED IN SCOPE OF SUPPLY OF CONTACT UNIT MARINE APPROVAL FOR LRS, DNV AND GL
ELECTRONIC TRIP UNIT VL 250 3-POLE, SYSTEM PROTECTION ETU10, LI IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 3-POLE, SYSTEM PROTECTION ETU20, LSI IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 3-POLE, SYSTEM PROTECTION ETU12, LIG 3 PHASES/3 WIRES IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 3-POLE, SYSTEM PROTECTION ETU22, LSIG 3 PHASES/3 WIRES IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 3-POLE, SYSTEM PROTECTION ETU22, LSIG 3 PHASES/4 WIRES WITH CONNECTING LEAD IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 3-POLE, SYSTEM PROTECTION ETU12, LIG 3 PHASES/3 WIRES IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 3-POLE, MOTOR/GENERATOR PROT. ETU10M, LI IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 3-POLE, MOTOR PROTECTION ETU30M, LI IR= 100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, TIME LAG CLASS II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 4-POLE, SYSTEM PROTECTION ETU10, LI IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N PROTECTED SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 4-POLE, SYSTEM PROTECTION ETU10, LI IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 4-POLE, SYSTEM PROTECTION ETU12, LIG IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 4-POLE, SYSTEM PROTECTION ETU20, LSI IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 4-POLE, SYSTEM PROTECTION ETU22, LSIG IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N PROTECTED SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 4-POLE, SYSTEM PROTECTION ETU12, LIG IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N PROTECTED SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 3-POLE, SYSTEM PROTECTION ETU10, LI IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 3-POLE, SYSTEM PROTECTION ETU20, LSI IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 3-POLE, SYSTEM PROTECTION ETU12, LIG 3 PHASES / 4 WIRES IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 3-POLE, SYSTEM PROTECTION ETU22, LSIG 3 PHASES/3 WIRES IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION SCREWED UNION CONNECTIONS IN SCOPE OF DELIVERY OF CONTACT UNIT
ELECTRONIC TRIP UNIT VL 250 3-POLE, SYSTEM PROTECTION ETU22, LSIG 3 PHASES/4 CABLES WITH CONNECTING CABLE IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION SCREW TERMINAL CONNECTIONS IN THE SCOPE OF SUPPLY OF THE CONTACT UNIT, TRIPPING MAGNET INTEGRATED
Menu