SIEMENS - Circuit breakers

Image
Part Number
Description
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=400A, RATED CURRENT IR=315-400A, OVERLOAD II=2000-4000A, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=400A, RATED CURRENT IR=315-400A, OVERLOAD II=2000-4000A, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE AUXILIARY SWITCH KIT 4HS(2NO+2NC)
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=400A, RATED CURRENT IR=315-400A, OVERLOAD II=2000-4000A, SHORT CIRCUIT UNDERVOLTAGE RELEASE 220 - 250 V AC AUXILIARY/ALARM SWITCH KIT 2HS(1NO+1NC)+1AS(1NO)
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=400A, RATED CURRENT IR=315-400A, OVERLOAD II=2000-4000A, SHORT CIRCUIT N PROTECTED
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=400A, RATED CURRENT IR=315-400A, OVERLOAD II=2000-4000A, SHORT CIRCUIT N NOT PROTECTED
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=400A, RATED CURRENT IR=315-400A, OVERLOAD II=2000-4000A, SHORT CIRCUIT N NOT PROTECTED WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
Circuit breaker VL630N Standard switching capacity Icu=55 kA, 415V AC 4-pole, system protection Overcurrent release TM, LI In=400 A, Rated current Ir=315...400 A, Overload protection, II=2000...4000 A, Short-circuit protection N unprotected without auxiliary release Auxiliary switch mounting kit 4 AUX (2 NO + 2 NC)
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU= 55KA, 415V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN= 400A, RATED CURRENT IR= 320...400A, OVERLOAD II= 2000...4000A, SHORT-CIRCUIT N PROTECTED (100%)
CIRCUIT-BREAKER VL 630H HIGH BREAKING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=400A, RATED CURRENT IR=315-400A, OVERLOAD II=2000-4000A, SHORT CIRCUIT
CIRCUIT-BREAKER VL 630H HIGH BREAKING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=400A, RATED CURRENT IR=315-400A, OVERLOAD II=2000-4000A, SHORT CIRCUIT N PROTECTED
CIRCUIT-BREAKER VL 630H HIGH BREAKING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=400A, RATED CURRENT IR=315-400A, OVERLOAD II=2000-4000A, SHORT CIRCUIT N NOT PROTECTED
CIRCUIT-BREAKER VL 630H HIGH BREAKING CAPACITY ICU= 70KA, 415V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN= 400A, RATED CURRENT IR= 320...400A, OVERLOAD II= 2000...4000A, SHORT-CIRCUIT N PROTECTED (100%)
CIRCUIT-BREAKER VL 630L VERY HIGH BREAKING CAPACITY ICU=100KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=400A, RATED CURRENT IR=315-400A, OVERLOAD II=2000-4000A, SHORT CIRCUIT
CIRCUIT-BREAKER VL 630L VERY HIGH BREAKING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=400A, RATED CURRENT IR=315-400A, OVERLOAD II=2000-4000A, SHORT CIRCUIT N PROTECTED
CIRCUIT-BREAKER VL 630L VERY HIGH BREAKING CAPACITY ICU=100KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=400A, RATED CURRENT IR=315-400A, OVERLOAD II=2000-4000A, SHORT CIRCUIT N NOT PROTECTED
CIRCUIT-BREAKER VL 630L VERY HIGH BREAKING CAPACITY ICU= 100KA, 415V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN= 400A, RATED CURRENT IR= 320...400A, OVERLOAD II= 2000...4000A, SHORT-CIRCUIT N PROTECTED (100%)
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=500A, RATED CURRENT IR=400-500A, OVERLOAD II=2500-5000A, SHORT CIRCUIT
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=500A, RATED CURRENT IR=400-500A, OVERLOAD II=2500-5000A, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=500A, RATED CURRENT IR=400-500A, OVERLOAD II=2500-5000A, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE AUXILIARY SWITCH KIT 4HS(2NO+2NC)
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=500A, RATED CURRENT IR=400-500A, OVERLOAD II=2500-5000A, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE AUXILIARY/ALARM SWITCH KIT 2HS(1NO+1NC)+1AS(1NO)
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, STARTER COMBINATION PROTECTION OVERCURRENT RELEASE MAGNETIC IN=500A, RATED CURRENT II=3250-6300A, SHORT CIRCUIT
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, STARTER COMBINATION PROTECTION OVERCURRENT RELEASE MAGNETIC IN=500A, RATED CURRENT II=3250-6300A, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE WITHOUT AUXILIARY/ALARM SWITCH
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, STARTER COMBINATION PROTECTION OVERCURRENT RELEASE MAGNETIC IN=500A, RATED CURRENT II=3250-6300A, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE AUXILIARY SWITCH KIT 4HS(2NO+2NC)
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=500A, RATED CURRENT IR=400-500A, OVERLOAD II=2500-5000A, SHORT CIRCUIT N PROTECTED
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=500A, RATED CURRENT IR=400-500A, OVERLOAD II=2500-5000A, SHORT CIRCUIT N NOT PROTECTED
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU= 55KA, 415V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN= 500A, RATED CURRENT IR= 400...500A, OVERLOAD II= 2500...5000A, SHORT-CIRCUIT N PROTECTED (100%)
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, MOTOR/ GENERATOR PROTECTION ELECTRONIC TRIP UNIT ETU10M, LI IN=500A, RATED CURRENT IR=200-500A, OVERLOAD II=1,25TO12,5XIN, SHORT CIRCUIT ETU COMMUNICATION-CAPABLE
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY ICU=55KA / 415 V AC 3 POLE, MOTOR/ GENERATOR PROTECTION ELECTRONIC TRIP UNIT ETU10M, LI IN=500A, RATED CURRENT IR=200-500A, OVERLOAD II=1,25TO12,5XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE ETU COMMUNICATION-CAPABLE
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY R.U.S.-C.BR.C.= 50 KA, 415 V AC 3-POLE, MOTOR PROTECTION ELECTRONIC TRIP UNIT ETU30M, LI IN=500A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 12.5 X IN, SHORT-CIRCUIT PROTECTION ETU COMMUNICATION-CAPABLE
CIRCUIT-BREAKER VL 630N STANDARD BREAKING CAPACITY R.U.S.-C.BR.C.= 50 KA, 415 V AC 3-POLE, MOTOR PROTECTION ELECTRONIC TRIP UNIT ETU30M, LI IN=500A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 12.5 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE ETU COMMUNICATION-CAPABLE
Menu
Mail Us
enquiry@onstocktrading.com