SIEMENS - 3ZS1310

Image
Part Number
Description
XB1 FOR ET 200S/DS-X/RS-X BRAKE CONTROL MODULE, 24V DC 4A FOR MOTORS WITH MECHANICAL BRAKES
XB2 FOR ET 200S DS-X/RS-X BRAKE CONTROL MODULE, 500V DC 0.7A, FOR MOTORS WITH MECHANICAL BRAKES
DISTANCE MODULE FOR ET 200S STARTER
XB3 BRAKE CONTROL MODUL DC 24V 4A
XB4 BRAKE CONTROL MODUL DC 500V 0,7A
CONTROL UNIT TO ET 200S
2DI DC24V CONTROL MODULE/COM F. ET200S HIGH FEATURE STARTER FOR LOCAL STARTER FUNCTIONS WITH COM-INTERFACE FOR PC-CABLE 6ED1057-1AA00-0BA0
2DI 24VDC LC COM CONTROL MODULE FOR ET200S HIGH FEATURE STARTER FOR ET 200S FAILSSAFE STARTER FOR LOCAL INPUT FUNCTIONS OR F. MANUAL OPERATION WITH COM INTERFACE FOR PC CABLE 6ED1057-1AA00-0BA0
XB5 FOR ET 200S MOTOR STARTER FOR TYPES DS1E-X, RS1E-X FOR F-DS1E-X, F-RS1E-X FOR DS1-X, RS1-X BRAKE CONTROL MODULE AC400V 0.5A FOR MOTORS WITH MECHANICAL BRAKES W/O DIGITAL INPUTS
TM-PF30 S47-B1 FOR ET 200S PM-D F1/2, TERMINAL MODULE FOR POTENTIAL GROUP, WITH SUPPLY U 1/2 AND SENSOR CONNECTION
TM-PF30 S47-B0 TERMINAL MODULE F. POWER MODULE PM-DF 1/2. FOR PARTIAL POTENTIAL GROUP W. SENSOR CONNECTION
TM-X15 S27-01 TERMINAL MODULE F. CONNECTION MODULE PM-X
TM-PF 30 S47-C1 FOR ET 200S PM-D F 3/4 TERMINAL MODULE FOR POTENTIAL GROUP, WITH SUPPLY U 1/2 AND SENSOR CONNECTION
TM-PF 30 S47-C0 FOR ET 200S PM-D F 3/4 TERMINAL MODULE FOR POTENTIAL GROUP, WITH SENSOR CONNECT.
TM-PF30 S47-D0 TERMINAL MODULE FOR CONTACT MULTIPLIER PM-D F5, FOR ACTUATOR CONNECTION, FOR MAX. 4 SINGLE-CHANNEL ACTUATORS FOR MAX. 2 2-CHANNEL ACTUATORS
PM-D F1 F. MOTOR STARTER POWER MODULE, FAILSAFE UP TO SAFETY CAT. 4 EN954-1 FOR MONIT. START EM. STOP PLUGABLE ONTO TM-PF30 S47-B0 -B1 30MM
PM-D F2 F. MOTOR STARTER POWER MODULE, FAILSAFE UP TO SAFETY CAT. 4 EN954-1 FOR AUTOSTART PROTECTIVE DOOR PLUGABLE ONTO TM-PF30 S47-B0 -B1 30MM
PM-D F4 F. MOTOR STARTER POWER MODULE, FAILSAFE EXPANSION TO PM-D F 1/2 FOR FURTHER ET200S RAIL PLUGABLE ONTO TM-PF30 S47-C0 -C1 30MM
PM-D F3 F. MOTOR STARTER POWER MODULE, FAILSAFE EXPANSION TO PM-D F 1/2 FOR ADDITIONAL POTENTIAL GROUP W. TIME DELAY 0.,5 TO 30 PLUGABLE ONTO TM-PF30 S47-C0 -C1 30MM UP TO SAFETY CAT. 3 EN954-1
PM-D F5 F. MOTOR STARTER POWER MODULE, FAILSAFE EXPANSION TO PM-D F1 TO F4, CONTACT MULTIPLIER W. 4 FLOATING RELAY CONTACTS, DC 24V MAX. 3A PER CONTACT PLUGABLE ONTO TM-PF30 S47-D0 30MM
F KIT FOR DIRECT STARTER DS1-X FOR ET200S SOLUTION LOCAL UP TO CAT 4/ PL E ACC. TO ISO13849-1 UP TO SIL 3 IEC 62061 FOR DIRECT STARTER CONSISTING OF 1 AUX. SWITCH BLOCK 1 CONTACT HOLDER WITH CONNECTING CABLE 2 CONTACT CARRIERS FOR TM
F KIT RS1-X FOR ET200S SOLUTION LOCAL UP TO CAT. 4 / PL E ISO 13849-1 UP TO SIL 3 IEC 62061 FOR REVERSING STARTER CONSISTING OF: 2 AUX. SWITCH BLOCKS 1 CONTACT HOLDER WITH CONNECTING CABLE 1 CONNECTING CABLE (JUMPER) 4 CONTACT CARRIERS FOR TM
F KIT DS WITH GOLD CONTACTS FOR ET200S SOL LOCALE UP TO SIL 3 IEC 62061 FOR DIRECT STARTER
PM-X F. MOTOR STARTER CONNECTION MODULE UP TO SAFETY CAT. 4 EN954-1 FOR FEEDBACK CIRCUIT AND INCOMING FEEDER PROTECTION 15MM PLUGABLE ONTO TM-X15 S27-01
TB PEN FOR ET 200S TERMINAL BLOCK PEN FOR STARTER WITH CONNECTION FOR FEEDER CABLE AND LOAD FOR INSTALLATION ON THE LEFT
TB PEN FOR ET 200S TERMINAL BLOCK PEN FOR STARTER WITH CONNECTION FOR LOAD FOR INSTALLATION IN THE MIDDLE
65MM TERMINAL BLOCK PEN FOR ET200S HIGH FEATURE STARTER, WITH CONN. FOR SUPPLY CABLE AND LOADS
65MM TERMINAL BLOCK PEN FOR ET200S HIGH FEATURE STARTER, WITH CONN. FOR LOADS
FOR PM-D F PROFISAFE WITH PROFIBUS OR PROFINET FOR POTENTIAL GROUP, FOR SUPPLY
FOR F-CM CONTACT MULTIPLIER CAN BE CODED FOR TRIPPING GROUP SG1 TO SG6 30MM
Menu
Mail Us
enquiry@onstocktrading.com