SIEMENS - 3WL12 size 2 to 4000 A / 690 VAC

Image
Part Number
Description
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V W. CONNECTION FLANGE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAW. NON-AUT. CIRCUIT-B. WITHOUT GUIDE FRAME 3-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V W. CONNECTION FLANGE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAW. NON-AUT. CIRCUIT-B. WITHOUT GUIDE FRAME 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V W. CONNECTION FLANGE
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 15 LI PROT. ADJUST.B. 0.5-1 IN MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ110-127V BZW DC 110-125V REQU. AC 50/60HZ 110V, DC 110V WITHOUT 1ST SHUNT TRIP WITH 2ND AUX. RELEASE "R", F3 UNDERVOLTAGE, NON-DEL. AC110 -127V, DC110-125V 2NO+2NC
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=100KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE II, IEC IN=1250A TO 690V, AC50/60HZ ICU=100KA AT 500V REAR CONNECTION HORIZONTAL