SIEMENS - 3WL12 size 2 to 4000 A / 690 VAC

Image
Part Number
Description
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=3200A TO 690V, AC50/60HZ ICU=100KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ 208-240V BZW DC 220-250V REQU. AC 50/60HZ 230V, DC 220V WITH 1ST AUXILIARY RELEASE SHUNT TRIP"F", F1 AC50/60HZ 230V/ DC 220V,100%ED WITHOUT 2ND SHUNT TRIP 2NO+2NC
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZE II, IEC IN=3200A TO 690V, AC50/60HZ ICU=100KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 45 LSIN PROT. ADJUST.B. 0.4-1 IN WITH CUBICLE BUS COMMUN./MEASURING FUNCT../ MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ 208-240V BZW DC 220-250V REQU. AC 50/60HZ 230V, DC 220V WITH 1ST AUXILIARY RELEASE SHUNT TRIP"F", F1 AC50/60HZ 230V/ DC 220V,100%ED WITHOUT
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=3200A TO 690V, AC50/60HZ ICU=100KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 45 LSIN PROT ADJUST. 0.4-1 IN WITH DISPLAY AND CUBICLE BUS COMM./MEASURING FUNC./EARTH FLT./ZSS OPTION MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ 208-240V BZW DC 220-250V REQU. AC 50/60HZ 230V, DC 220V WITH 1ST AUXILIARY RELEASE SHUNT TRIP"F", F1 AC50/60HZ 230V/
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
DRAW-OUT CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR TERMINALS HORIZONTAL ELECTRONIC TRIP UNIT ETU 27 LSING PROT. ADJUST.B 0.4-1IN EARTH FAULT/ N-PROT. INTEGRATED MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ 208-240V BZW DC 220-250V REQU. AC 50/60HZ 230V, DC 220V WITH 1ST AUXILIARY RELEASE SHUNT TRIP"F", F1 AC50/60HZ 230V/ DC 220V,100%ED WITH 2ND AUX. RELEASE &qu
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL ELECTRONIC TRIP UNIT ETU 27 LSING PROT. ADJUST.B 0.4-1IN EARTH FAULT/ N-PROT. INTEGRATED MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ 208-240V BZW DC 220-250V REQU. AC 50/60HZ 230V, DC 220V WITH 1ST AUXILIARY RELEASE SHUNT TRIP"F", F1 AC50/60HZ 230V/ DC 220V,100%ED WITHOUT 2ND SHUNT TRIP 2NO
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=80KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=100KA AT 500V REAR CONNECTION VERTICAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=4000A TO 690V, AC50/60HZ ICU=100KA AT 500V REAR CONNECTION VERTICAL