SIEMENS - 3WL11 size 1 to 2000 A / 690 VAC

Image
Part Number
Description
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V W. CONNECTION FLANGE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAW. NON-AUT. CIRCUIT-B. WITHOUT GUIDE FRAME 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V W. CONNECTION FLANGE
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 2NO+2NC
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ 208-240V BZW DC 220-250V REQU. AC 50/60HZ 230V, DC 220V WITHOUT 1ST SHUNT TRIP WITH 2ND AUX. RELEASE "R", F3 UNDERVOLTAGE, NON-DEL. AC 208-240V, DC 220-250V 2NO+2NC
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 2NO+2NC
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR DC 24-30 V REQUEST DC 24V WITHOUT 1ST SHUNT TRIP WITH 2ND AUX. RELEASE "R", F3 UNDERVOLTAGE, NON-DEL. AC 208-240V, DC 220-250V 2NO+2NC
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=55KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 45 LSIN PROT. ADJUST.B. 0.4-1 IN WITH CUBICLE BUS COMMUN./MEASURING FUNCT../ W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 4NO+4NC
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V W. CONNECTION FLANGE
WITHDRAW. NON-AUT. CIRCUIT-B. WITHOUT GUIDE FRAME 3-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE I, IEC IN=800A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE