SIEMENS - 3WL11 size 1 to 2000 A / 690 VAC

Image
Part Number
Description
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 27 LSING PROT. ADJUST.B 0.4-1IN EARTH FAULT/ N-PROT. INTEGRATED MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ 208-240V BZW DC 220-250V REQU. AC 50/60HZ 230V, DC 220V WITH 1ST AUXILIARY RELEASE SHUNT TRIP"F", F1 AC50/60HZ 230V/ DC 220V,100%ED WITHOUT 2ND SHUNT TRIP 4NO
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION VERTICAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V W. CONNECTION FLANGE
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 4-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION VERTICAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V W. CONNECTION FLANGE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAW. NON-AUT. CIRCUIT-B. WITHOUT GUIDE FRAME 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=630A TO 690V, AC50/60HZ ICU=85KA AT 500V W. CONNECTION FLANGE
Menu
Mail Us
enquiry@onstocktrading.com