FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 3-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 3-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITHOUT GUIDE FRAME 3-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITH GUIDE FRAME 3-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITH GUIDE FRAME 3-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITH GUIDE FRAME 3-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V W. CONNECTION FLANGE
FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 4-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 4-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION HORIZONTAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 4-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 4-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITHOUT GUIDE FRAME 4-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITH GUIDE FRAME 4-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITH GUIDE FRAME 4-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITH GUIDE FRAME 4-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V W. CONNECTION FLANGE
FIXED-MOUNTED CIRCUIT BREAKER APPROVED TO UL489 3-POLE, BG II, IN=2000A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 2NO+2NC
FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 3-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 3-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION HORIZONTAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 3-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 3-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITHOUT GUIDE FRAME 3-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITH GUIDE FRAME 3-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITH GUIDE FRAME 3-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITH GUIDE FRAME 3-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V W. CONNECTION FLANGE
FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 4-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 4-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION HORIZONTAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 4-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNT NON-AUT. CIRCUIT-B. APPROVED TO UL489 4-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITHOUT GUIDE FRAME 4-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITH GUIDE FRAME 4-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. APPROVED TO UL489 WITH GUIDE FRAME 4-POLE, BG II, IN=2500A AC 50/60 HZ, IEC: TO 690V, 100KA AT 440V UL: TO 600V, 100KA AT 480V REAR CONNECTION VERTICAL