SIEMENS - 3WL

Image
Part Number
Description
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V W. CONNECTION FLANGE
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V W. CONNECTION FLANGE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAW. NON-AUT. CIRCUIT-B. WITHOUT GUIDE FRAME 3-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V W. CONNECTION FLANGE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAW. NON-AUT. CIRCUIT-B. WITHOUT GUIDE FRAME 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V W. CONNECTION FLANGE
Withdrawable non-automatic air circuit breaker with slide-in module frame 3-pole, Size 2, IEC In=2500 A to 690 V, 50/60 Hz AC Icu=66 kA at 500 V Rear horizontal connection without overcurrent release With manual operating mechanism with memory with mechanical calling With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC K07= Caution!!! Order code K07 with n
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE II, IEC IN=2500A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE ELECTRONIC TRIP UNIT ETU 15 LI PROT. ADJUST.B. 0.5-1 IN W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITH 2ND AUX. RELEASE "RC", F4 UNDERVOLTAGE, W.DELAY 0,2-3,2S AC208-240V, DC220-250V, 100% ED 2NO+2NC
Fixed-mounted circuit breaker 3-pole, Size 2, IEC In=2500 A to 690 V, 50/60 Hz AC Icu=66 kA at 500 V Rear horizontal connection Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with memory Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "R", F3 Undervoltage, instant. 208-240 V AC, 220-250 V
Menu
Mail Us
enquiry@onstocktrading.com