FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL WITHOUT OVERCURRENT TRIP W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 2NO+2NC
fixed-mounted circuit breaker 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V frnt.conn. top/bot. single-hole Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in Motorized/manual operating mechanism with memory Drive motor AC 50/60 Hz 208-240 V or 220-250 V DC Activation AC 50/60 Hz 230 V, 220 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor With 2nd auxilia
withdrawable circuit breaker without guide frame 3-pole, size I, IEC In=1600A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request without 1st auxiliary release without 2nd auxiliary release 2NO+2NC
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ110-127V BZW DC 110-125V REQU. AC 50/60HZ 110V, DC 110V WITHOUT 1ST SHUNT TRIP WITH 2ND AUX. RELEASE "R", F3 UNDERVOLTAGE, NON-DEL. AC110 -127V, DC110-125V 2NO+2NC
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 2NO+2NC K07 = TRIPPED-SIGNALLING CONTACT, 1W
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 45 LSIN PROT. ADJUST.B. 0.4-1 IN WITH CUBICLE BUS COMMUN./MEASURING FUNCT../ W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 4NO+4NC
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 45 LSIN PROT. ADJUST.B. 0.4-1 IN WITH CUBICLE BUS COMMUN./MEASURING FUNCT../ MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ 208-240V BZW DC 220-250V REQU. AC 50/60HZ 230V, DC 220V WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 4NO+4NC
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=1600A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 45 LSIN PROT. ADJUST.B. 0.4-1 IN WITH CUBICLE BUS COMMUN./MEASURING FUNCT../ MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ 208-240V BZW DC 220-250V REQU. AC 50/60HZ 230V, DC 220V WITH 1ST AUXILIARY RELEASE SHUNT TRIP"F", F1 AC50/60HZ 230V/ DC 220V,100%ED WITHOUT 2ND