FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNTED CIRCUIT BREAKER 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V W. CONNECTION FLANGE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 3-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAW. NON-AUT. CIRCUIT-B. WITHOUT GUIDE FRAME 3-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V W. CONNECTION FLANGE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. SINGLE-HOLE
FIXED-MOUNT NON-AUT. CIRCUIT-B. 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V FRNT.CONN. TOP/BOT. DUAL-HOLE
WITHDRAW. NON-AUT. CIRCUIT-B. WITHOUT GUIDE FRAME 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL
WITHDRAW. NON-AUT. CIRCUIT-B. WITH GUIDE FRAME 4-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V W. CONNECTION FLANGE
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 2NO+2NC
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 2NO+2NC K07 = TRIPPED-SIGNALLING CONTACT, 1W NOT POSSIBLE WITH OPTION F02
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=1250A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 2NO+2NC
withdrawable circuit breaker with guide frame 3-pole, size i, IEC In=1250A to 690V, AC50/60Hz Icu=66kA at 500V rear connection horizontal Overcurrent release ETU 25 LSI protection adjustable 0.4-1 in With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 230 V AC/220 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC K07= Tripped signaling contact, 1 CO