WITHDRAW. NON-AUT. CIRCUIT-B. WITHOUT GUIDE FRAME 3-POLE, SIZE I, IEC IN=1000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL WITHOUT OVERCURRENT TRIP MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ110-127V BZW DC 110-125V REQU. AC 50/60HZ 110V, DC 110V WITH 1ST AUXILIARY RELEASE SHUNT TRIP"F", F1 AC50/60HZ 110V/ DC 110V, 100%ED WITHOUT 2ND SHUNT TRIP
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 15 LI PROT. ADJUST.B. 0.5-1 IN MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ 208-240V BZW DC 220-250V REQU. AC 50/60HZ 230V, DC 220V WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 2NO+2NC
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZE I, IEC IN=1000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 15 LI PROT. ADJUST.B. 0.5-1 IN W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 2NO+2NC
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION VERTICAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR DC 24-30 V REQUEST DC 24V WITHOUT 1ST SHUNT TRIP WITH 2ND AUX. RELEASE "R", F3 UNDERVOLTAGE, NON-DEL. DC 24V 2NO+2NC C01 = MECH. OPERATIONS COUNTER T40 = DOOR SEALING FRAME
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 2NO+2NC
FIXED-MOUNTED CIRCUIT BREAKER 3-POLE, SIZE I, IEC IN=1000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 2NO+2NC K07 = TRIPPED-SIGNALLING CONTACT, 1W NOT POSSIBLE WITH OPTION F02
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZE I, IEC IN=1000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN MOT./MAN. OPER.MECHAN. W.STOR. DRIVE MOTOR AC 50/60HZ 208-240V BZW DC 220-250V REQU. AC 50/60HZ 230V, DC 220V WITH 1ST AUXILIARY RELEASE SHUNT TRIP"F", F1 AC50/60HZ 230V/ DC 220V,100%ED WITHOUT 2ND SHUNT TRIP 4NO+4NC
WITHDRAWABLE CIRCUIT BREAKER WITH GUIDE FRAME 3-POLE, SIZE I, IEC IN=1000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 25 LSI PROT. ADJUST.B. 0.4-1 IN W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 2NO+2NC
WITHDRAWABLE CIRCUIT BREAKER WITHOUT GUIDE FRAME 3-POLE, SIZE I, IEC IN=1000A TO 690V, AC50/60HZ ICU=66KA AT 500V REAR CONNECTION HORIZONTAL ELECTRONIC TRIP UNIT ETU 45 LSIN PROT. ADJUST.B. 0.4-1 IN WITH CUBICLE BUS COMMUN./MEASURING FUNCT../ W. MAN. OPER. MECHAN. & STORAGE WITH MECHANICAL REQUEST WITHOUT 1ST SHUNT TRIP WITHOUT 2ND SHUNT TRIP 4NO+4NC